Speed-quality divergence in a one-handed square-knot OSCE station: implications for total-score interpretation.
4 affiliations
- 1Medical Simulation Center, Shantou University Medical College, No. 22 Xinling Road, Shantou, 515041, Guangdong, China.
- 2The First Affiliated Hospital of Shantou University Medical College, Shantou, Guangdong, China.
- 3Medical Simulation Center, Shantou University Medical College, No. 22 Xinling Road, Shantou, 515041, Guangdong, China. [email protected].
- 4Medical Simulation Center, Shantou University Medical College, No. 22 Xinling Road, Shantou, 515041, Guangdong, China. [email protected].
Abstract
Objective
To describe the relation between speed, graded knot tightness, and the compensatory total score in a one-handed square-knot Objective Structured Clinical Examination (OSCE) station at one institution.Results
Scoring records from 449 undergraduate medical students were retrospectively analyzed. Full-mark rates were 74.2% for speed and 33.2% for tightness, a 41.0-percentage-point ceiling contrast. Among the 433 students (96.4%) who met the 60% passing threshold (≥ 15/25), 284 (65.6%, 95% confidence interval [CI] 61.0-69.9) scored below the stringent 5/5 tightness ceiling, a rubric-defined rather than clinical bar. The most concerning rubric-defined subgroup comprised the 25 passers (5.8%, 95% CI 3.9-8.4) who received 0/5 ("clearly visible gap"), although this category has not been validated as a patient-safety endpoint. At a 70% threshold, 61.7% (95% CI 56.7-66.4) remained below the ceiling. In the pooled binary model, T4 had the largest odds ratio; its positive association persisted in both station/rater groups, although its magnitude differed and it was not the largest association in Station A. T4 is a marker, not a causal lever. This single-center finding is hypothesis-generating; multi-site, multi-rater validation is required.
Related
- Long IVUS-attenuated plaque without no-reflow: histological findings of captured embolic debris and implications for the interpretation of IVUS attenuation: a case report
- Clinical similarity, economic divergence: cost-effectiveness and population health implications of dietary, pharmacological, and exercise interventions in older adults with type 2 diabetes: a secondary analysis of a randomized controlled trial.
- Germline Variants Absent from Global Reference Databases in Malawian DLBCL Patients: Implications for Variant Interpretation in African Genomic Medicine
- Score interpretation thresholds for the European Organisation for Research and Treatment of Cancer thyroid cancer quality of life questionnaire (EORTC QLQ-THY34). An international prospective study.
- Evaluating influenza-related short videos on Chinese platforms: information quality, user engagement, and public health implications
BibTeX
@article{yue2026speedquality,
title = {{Speed-quality divergence in a one-handed square-knot OSCE station: implications for total-score interpretation.}},
author = {Minghui Yue and Junjun Li and Yang Liu and Jiachun Zheng and Weishan Zhang and Chujun Shi},
journal = {BMC research notes},
year = {2026},
month = aug,
doi = {10.1186/s13104-026-07951-y},
url = {https://europepmc.org/article/MED/42968197},
note = {CC BY-NC-ND},
}
RIS
TY - JOUR
TI - Speed-quality divergence in a one-handed square-knot OSCE station: implications for total-score interpretation.
AU - Minghui Yue
AU - Junjun Li
AU - Yang Liu
AU - Jiachun Zheng
AU - Weishan Zhang
AU - Chujun Shi
PY - 2026
DA - 2026/08/04
JO - BMC research notes
DO - 10.1186/s13104-026-07951-y
UR - https://europepmc.org/article/MED/42968197
AB - Objective To describe the relation between speed, graded knot tightness, and the compensatory total score in a one-handed square-knot Objective Structured Clinical Examination (OSCE) station at one institution.Results Scoring records from 449 undergraduate medical students were retrospectively analyzed. Full-mark rates were 74.2% for speed and 33.2% for tightness, a 41.0-percentage-point ceiling contrast. Among the 433 students (96.4%) who met the 60% passing threshold (≥ 15/25), 284 (65.6%, 95% confidence interval [CI] 61.0-69.9) scored below the stringent 5/5 tightness ceiling, a rubric-defined rather than clinical bar. The most concerning rubric-defined subgroup comprised the 25 passers (5.8%, 95% CI 3.9-8.4) who received 0/5 ("clearly visible gap"), although this category has not been validated as a patient-safety endpoint. At a 70% threshold, 61.7% (95% CI 56.7-66.4) remained below the ceiling. In the pooled binary model, T4 had the largest odds ratio; its positive association persisted in both station/rater groups, although its magnitude differed and it was not the largest association in Station A. T4 is a marker, not a causal lever. This single-center finding is hypothesis-generating; multi-site, multi-rater validation is required.
SN - 1756-0500
ER -