Skip to content
DraconiticResearch
Search Sources API
201,642 studies31 sourcesUpdated 31 min ago
Peer-reviewedCC BY-NC 4.0European Heart Journal. Case Reports

Long IVUS-attenuated plaque without no-reflow: histological findings of captured embolic debris and implications for the interpretation of IVUS attenuation: a case report

Abstract

Background: The no-reflow phenomenon during percutaneous coronary intervention (PCI) is commonly associated with distal embolization from high-risk coronary plaques, including lesions with intravascular ultrasound (IVUS)-defined attenuation. Histopathological analysis of embolic debris captured during PCI is rarely reported and may provide additional insights into the relationship between plaque characteristics and coronary flow outcomes.

Case summary: An 84-year-old man presented with acute coronary syndrome and decompensated heart failure. Coronary angiography demonstrated severe multi-vessel coronary artery disease, including a long right coronary artery lesion with extensive IVUS attenuation. Given the high risk of distal embolization, PCI was performed using a distal protection device. Drug-eluting stents were successfully implanted, and Thrombolysis In Myocardial Infarction flow grade 3 was maintained throughout the procedure without slow flow or no reflow. Histopathological examination of debris captured by the distal protection device demonstrated predominantly fibrin- and collagen-rich thrombotic material with macrophage infiltration and no apparent abundant lipid component. The patient experienced an uneventful recovery and was discharged without procedural complications.

Discussion: The composition of retrieved embolic debris captured during PCI differed from the expected imaging phenotype. This case highlights the potential discrepancy between intracoronary imaging appearance and embolized material and underscores the multifactorial nature of coronary slow flow and no reflow. Careful interpretation of IVUS attenuation and embolic pathology is warranted when assessing procedural risk.

Related

  1. Tartrazine-Induced Toxicity Is Attenuated by Naringenin in Wistar Rats: A Biochemical, Histological, and Behavioral Study
    Eduardo Rivadeneyra-Domínguez, Juan Francisco Rodríguez-Landa, David J. Salazar-Camacho +5
    NutrientsPeer-reviewedCC BYFull textNutritionEurope PMC
  2. Limited tissue persistence confirms attenuation of live-attenuated chikungunya vaccine VLA1553 in non-human primates.
    Pierre Roques, Andrea Fritzer, Nathalie Dereuddre-Bosquet +5
    NPJ vaccinesPeer-reviewedCC BYFull textEpidemiology & public healthEurope PMCDOAJ
  3. The clinical course of nasal polyps in relation with histological and radiological findings
    Suh-Young Lee, Hee Young Na, Margaret Mbabazi Sebbale +5
    Asia Pacific allergyPeer-reviewedCC BY-NC-NDFull textGeneral medicineEurope PMC
  4. Histological control data in target and non-target organs versus induced findings from 74 amphibian metamorphosis assays (AMAs) using the African clawed frog (Xenopus laevis)
    Paula Ortega, Tanja Razinger, Olivia Kristina Richard +10
    Journal of Toxicologic PathologyPeer-reviewedCC BY-NC-ND 4.0Full textPharmacology & toxicologyPMC
  5. Ribociclib-Induced Vitiligo: A Case Report with Histological, Dermatoscopic, Confocal Microscopy, and LC-OCT Findings Along with a Narrative Literature Review.
    Silvia Mezi, Flavia Persechino, Andrea Ascione +6
    Dermatology practical & conceptualPeer-reviewedCC BY-NCFull textGeneral medicineEurope PMC
BibTeX
@article{suzuki2026long,
  title = {{Long IVUS-attenuated plaque without no-reflow: histological findings of captured embolic debris and implications for the interpretation of IVUS attenuation: a case report}},
  author = {Kenta Suzuki and Tomomi Koizumi and Yukinori Inadome},
  journal = {European Heart Journal. Case Reports},
  year = {2026},
  month = oct,
  doi = {10.1093/ehjcr/ytag739},
  url = {https://doi.org/10.1093/ehjcr/ytag739},
  note = {CC BY-NC 4.0},
}
RIS
TY  - JOUR
TI  - Long IVUS-attenuated plaque without no-reflow: histological findings of captured embolic debris and implications for the interpretation of IVUS attenuation: a case report
AU  - Kenta Suzuki
AU  - Tomomi Koizumi
AU  - Yukinori Inadome
PY  - 2026
DA  - 2026/10/08
JO  - European Heart Journal. Case Reports
DO  - 10.1093/ehjcr/ytag739
UR  - https://doi.org/10.1093/ehjcr/ytag739
AB  - Background: The no-reflow phenomenon during percutaneous coronary intervention (PCI) is commonly associated with distal embolization from high-risk coronary plaques, including lesions with intravascular ultrasound (IVUS)-defined attenuation. Histopathological analysis of embolic debris captured during PCI is rarely reported and may provide additional insights into the relationship between plaque characteristics and coronary flow outcomes.  Case summary: An 84-year-old man presented with acute coronary syndrome and decompensated heart failure. Coronary angiography demonstrated severe multi-vessel coronary artery disease, including a long right coronary artery lesion with extensive IVUS attenuation. Given the high risk of distal embolization, PCI was performed using a distal protection device. Drug-eluting stents were successfully implanted, and Thrombolysis In Myocardial Infarction flow grade 3 was maintained throughout the procedure without slow flow or no reflow. Histopathological examination of debris captured by the distal protection device demonstrated predominantly fibrin- and collagen-rich thrombotic material with macrophage infiltration and no apparent abundant lipid component. The patient experienced an uneventful recovery and was discharged without procedural complications.  Discussion: The composition of retrieved embolic debris captured during PCI differed from the expected imaging phenotype. This case highlights the potential discrepancy between intracoronary imaging appearance and embolized material and underscores the multifactorial nature of coronary slow flow and no reflow. Careful interpretation of IVUS attenuation and embolic pathology is warranted when assessing procedural risk.
SN  - 2514-2119
ER  -