Skip to content
DraconiticResearch
Search Sources API
203,234 studies31 sourcesUpdated 46 min ago
PreprintCC BY 4.0arXiv

Inverse-Designed Anisotropic Intrastromal Corneal Exoskeletons for Keratoconus: A Three-Dimensional Computational Feasibility Study

Abstract

We propose G-EXO, an inverse-designed intrastromal corneal exoskeleton for keratoconus. Unlike conventional intracorneal ring approaches, G-EXO is conceived as a patient-customizable, sectorial and anisotropic scaffold whose geometry and stiffness are optimized to redistribute corneal deformation and reduce asymmetric optical aberrations. We develop a three-dimensional finite-element screening model with localized ectatic weakening, physiological intraocular pressure, and an intrastromal reinforcement domain. A representative design produced a modest but consistent reduction in pressure-induced coma, with a mesh-refined estimate of about 5%, while displacement and stress metrics were more numerically stable. The study is presented as a computational feasibility framework rather than a clinical validation. Its main contribution is to formulate intrastromal reinforcement as a free-form optical-biomechanical inverse-design problem. Patient-specific tomography, nonlinear anisotropic corneal mechanics, full optical modeling, and ex-vivo validation are identified as the next steps.

Related

  1. Numerical Verification Limits of Asymmetric Intrastromal Hydrogel Reinforcement for Decentered Keratoconus
    Juan Sumaya-Martínez, Alan Altamirano-Torres
    arXivPreprintCC BY 4.0Full textBiological & medical physicsarXiv
  2. Dynamics of thermalization in classical three-dimensional many-body systems: Non-Maxwellian distributions and the role of anisotropic trapping
    Roberto Onofrio, Bala Sundaram
    arXivPreprintCC BY 4.0Full textAtomic, molecular & optical physicsComputational physicsarXiv
  3. Evidence of an anisotropic Griffiths phase in a two-dimensional van der Waals magnet
    Anupam K. Singh, Dhananjay Nair, Holger Meyerheim +2
    arXivPreprintarXiv licenceFull textCondensed matterarXiv
  4. Identifiability of the three-dimensional anisotropic thermal-conductivity tensor in thermoreflectance measurements: Single-orientation limits and full-tensor recover
    Dihui Wang, Heng Ban
    arXivPreprintCC BY 4.0Full textApplied physics & instrumentationarXiv
  5. Anisotropic magnetoresistance of two-dimensional Rashba systems with in-plane Zeeman field and point-like disorder
    Igor Gornyi, Alexander Khaetskii
    arXivPreprintCC BY 4.0Full textCondensed matterarXiv
BibTeX
@misc{sumayamartinez2026inversedesigned,
  title = {{Inverse-Designed Anisotropic Intrastromal Corneal Exoskeletons for Keratoconus: A Three-Dimensional Computational Feasibility Study}},
  author = {J. Sumaya-Martinez and Alan Altamirano},
  howpublished = {arXiv},
  year = {2026},
  month = oct,
  doi = {10.48550/arxiv.2610.08529},
  eprint = {2610.08529},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2610.08529},
  note = {CC BY 4.0},
}
RIS
TY  - UNPB
TI  - Inverse-Designed Anisotropic Intrastromal Corneal Exoskeletons for Keratoconus: A Three-Dimensional Computational Feasibility Study
AU  - J. Sumaya-Martinez
AU  - Alan Altamirano
PY  - 2026
DA  - 2026/10/06
PB  - arXiv
DO  - 10.48550/arxiv.2610.08529
UR  - https://arxiv.org/abs/2610.08529
AB  - We propose G-EXO, an inverse-designed intrastromal corneal exoskeleton for keratoconus. Unlike conventional intracorneal ring approaches, G-EXO is conceived as a patient-customizable, sectorial and anisotropic scaffold whose geometry and stiffness are optimized to redistribute corneal deformation and reduce asymmetric optical aberrations. We develop a three-dimensional finite-element screening model with localized ectatic weakening, physiological intraocular pressure, and an intrastromal reinforcement domain. A representative design produced a modest but consistent reduction in pressure-induced coma, with a mesh-refined estimate of about 5%, while displacement and stress metrics were more numerically stable. The study is presented as a computational feasibility framework rather than a clinical validation. Its main contribution is to formulate intrastromal reinforcement as a free-form optical-biomechanical inverse-design problem. Patient-specific tomography, nonlinear anisotropic corneal mechanics, full optical modeling, and ex-vivo validation are identified as the next steps.
ER  -