Skip to content
DraconiticResearch
Search Sources API
203,234 studies31 sourcesUpdated 49 min ago
PreprintCC BY 4.0arXiv

Numerical Verification Limits of Asymmetric Intrastromal Hydrogel Reinforcement for Decentered Keratoconus

Abstract

Spatially tailored intrastromal hydrogel scaffolds have been proposed for decentered keratoconus, but their mechanical and optical benefits require stringent numerical validation. We reanalyze conforming two-material finite-element benchmarks and earlier optomechanical screening calculations, distinguishing solver verification from constitutive adequacy and treatment efficacy. In a curved corneal-patch benchmark with a fixed-volume rectangular inclusion, the apparent peak-displacement benefit of an offset over a centered inclusion changes from -5.66% to +1.73% across four tetrahedral meshes, while absolute displacements remain strongly mesh dependent. On the finest mesh, the quadratic term in the Green-Lagrange strain tensor contributes about 18% of the root-mean-square magnitude of the linearized strain; the underlying finite-element solutions themselves remain linear elastic. Earlier optical screening was sensitive to corneal orientation, mesh refinement and wavefront-reference conventions and is not retained as validated evidence. These observations do not establish superiority of asymmetric reinforcement. Instead, they motivate prespecified criteria for geometry-invariant finite-strain simulations, two-material interface verification, optical wavefront convergence, and independent experimental validation. No clinical recommendation is implied.

Related

  1. Inverse-Designed Anisotropic Intrastromal Corneal Exoskeletons for Keratoconus: A Three-Dimensional Computational Feasibility Study
    J. Sumaya-Martinez, Alan Altamirano
    arXivPreprintCC BY 4.0Full textBiological & medical physicsarXiv
  2. Executable verification through formalized expert reasoning in astronomical spectroscopy
    Haosong Wang, Ting Tan, Ji Yao +5
    HALPreprintLicence not statedGeneral astronomyApplied physics & instrumentationHAL
  3. Dynamic calibration method for the system constant of high-spectral-resolution lidar with airborne experimental verification
    Li Ping, Fanqian Meng, Juxin yang +3
    Optics ExpressPeer-reviewedLicence not statedOptics & photonicsCrossref
  4. Challenges in the verification of MOSAIX ASIC for ALICE ITS3
    Simone Scarfi, Matteo Lupi, Adithya Pulli
    arXivPreprintarXiv licenceFull textApplied physics & instrumentationHigh-energy & particle physicsarXiv
  5. Molecular-Dynamics Verification of Effective Gravity under Heat Conduction
    Satoshi Uruno, Naoko Nakagawa
    arXivPreprintarXiv licenceFull textStatistical & nonlinear physicsarXiv
BibTeX
@misc{sumayamartinez2026numerical,
  title = {{Numerical Verification Limits of Asymmetric Intrastromal Hydrogel Reinforcement for Decentered Keratoconus}},
  author = {Juan Sumaya-Martínez and Alan Altamirano-Torres},
  howpublished = {arXiv},
  year = {2026},
  month = nov,
  doi = {10.48550/arxiv.2611.01889},
  eprint = {2611.01889},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2611.01889},
  note = {CC BY 4.0},
}
RIS
TY  - UNPB
TI  - Numerical Verification Limits of Asymmetric Intrastromal Hydrogel Reinforcement for Decentered Keratoconus
AU  - Juan Sumaya-Martínez
AU  - Alan Altamirano-Torres
PY  - 2026
DA  - 2026/11/01
PB  - arXiv
DO  - 10.48550/arxiv.2611.01889
UR  - https://arxiv.org/abs/2611.01889
AB  - Spatially tailored intrastromal hydrogel scaffolds have been proposed for decentered keratoconus, but their mechanical and optical benefits require stringent numerical validation. We reanalyze conforming two-material finite-element benchmarks and earlier optomechanical screening calculations, distinguishing solver verification from constitutive adequacy and treatment efficacy. In a curved corneal-patch benchmark with a fixed-volume rectangular inclusion, the apparent peak-displacement benefit of an offset over a centered inclusion changes from -5.66% to +1.73% across four tetrahedral meshes, while absolute displacements remain strongly mesh dependent. On the finest mesh, the quadratic term in the Green-Lagrange strain tensor contributes about 18% of the root-mean-square magnitude of the linearized strain; the underlying finite-element solutions themselves remain linear elastic. Earlier optical screening was sensitive to corneal orientation, mesh refinement and wavefront-reference conventions and is not retained as validated evidence. These observations do not establish superiority of asymmetric reinforcement. Instead, they motivate prespecified criteria for geometry-invariant finite-strain simulations, two-material interface verification, optical wavefront convergence, and independent experimental validation. No clinical recommendation is implied.
ER  -