Neutrosophic reliability assessment of smart grid power generation system using universal generating function under Weibull distribution

  1. 1Department of Mathematics and Statistics, Manipal University Jaipur

Abstract

Reliability is essential for each complex system. The key objective of the present study is to use a neutrosophic framework to handle data uncertainty in reliability modeling of power generation systems in smart grids. Numerous traditional approaches are capable of characterizing epistemic uncertainty, yet each owns respective limitations. To overcome the limitation of classical model problem, a novel approach as neutrosophic set is introduced, utilizing single valued triangular neutrosophic number (SVTNN). Also, it is integrated with universal generating function(UGF) and Weibull distribution to capture uncertainty more efficiently in reliability modeling of power generation system. Power generation system is made up by eight components in which “fuel supply” unit is parallel to “renewable sources” unit and “power conditioning” unit is parallel to “energy storage” unit. System behaviour is observed by numerical results of reliability and mean time to failure in neutrosophic environments at various time instants under data uncertainty. The innovation of proposed work is combination of neutrosophic sets with U.G.F and weibull based reliability framework to handle uncertainty effectively by comparing with conventional fuzzy approaches. A comparative analysis which based on reduction study and reliability by triangular fuzzy number (TFN), is performed in this study. A sensitivity analysis is also performed. The comparative analysis as uncertainty b1111ands highlighted graphically. The conclusion of current study is neutrosophic reliability framework effectively capturing uncertainty, indeterminacy, and falsity as compared to traditional reliability framework or fuzzy based approaches in power generation system.

Related

  1. Occurrence, distribution and risk assessment of pharmaceuticals and personal care products in Djibouti aquifer
    Abdillahi Elmi Adaneh, Pascal Wong-Wah-Chung, Mohamed Osman Awaleh +4
    Environmental Science and Pollution ResearchPeer-reviewedLicence not statedFull text1 citedAnalytical chemistryEnvironmental science & pollutionHAL
  2. Spatial distribution and pollution assessment of potentially toxic elements in stream sediments of the Luis Moya region, Central Mexico: Evidence from mining-affected areas
    Heriberto Morales-deAvila, Mélida Gutiérrez, Julian Gonzalez-Trinidad +1
    Journal of Environmental Science, Health & SustainabilityPeer-reviewedCC BY-NC-NDFull textEnvironmental science & pollutionDOAJ
  3. Uncertainty-aware bilevel energy storage planning for active distribution networks: A fixed-topology DistFlow-based MISOCP framework with voltage-security assessment
    Zhenhua Miao, Ziyan Li, Yongjie Wang
    PLOS OnePeer-reviewedCC BY 4.0Full textGeology & geochemistryPhysiologyPLOS
  4. Biodiversity credits hold promise, yet credit-generating protocols require safeguards to realize potential
    Katherine Culbertson, Sarah Federman, Lucia Catherine Camp +1
    Environmental Research LettersPeer-reviewedCC BY 4.0Full textEnvironmental science & pollutionCrossref
  5. PrecipCorrDiff: A Deep Learning Framework for Generating 0.0625∘ High-Resolution IMD Gridded Precipitation Data
    Bipin Kumar, Rajib Chattopadhyay, Harsh P. Bachhav +7
    arXivPreprintarXiv licenceFull textAtmospheric science & meteorologyarXiv
BibTeX
@article{agarwal2026neutrosophic,
  title = {{Neutrosophic reliability assessment of smart grid power generation system using universal generating function under Weibull distribution}},
  author = {Riya Agarwal and Monika Saini and Ashish Kumar},
  journal = {Discover Sustainability},
  year = {2026},
  month = jul,
  doi = {10.1007/s43621-026-04057-0},
  url = {https://doi.org/10.1007/s43621-026-04057-0},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - Neutrosophic reliability assessment of smart grid power generation system using universal generating function under Weibull distribution
AU  - Riya Agarwal
AU  - Monika Saini
AU  - Ashish Kumar
PY  - 2026
DA  - 2026/07/01
JO  - Discover Sustainability
DO  - 10.1007/s43621-026-04057-0
UR  - https://doi.org/10.1007/s43621-026-04057-0
AB  - Reliability is essential for each complex system. The key objective of the present study is to use a neutrosophic framework to handle data uncertainty in reliability modeling of power generation systems in smart grids. Numerous traditional approaches are capable of characterizing epistemic uncertainty, yet each owns respective limitations. To overcome the limitation of classical model problem, a novel approach as neutrosophic set is introduced, utilizing single valued triangular neutrosophic number (SVTNN). Also, it is integrated with universal generating function(UGF) and Weibull distribution to capture uncertainty more efficiently in reliability modeling of power generation system. Power generation system is made up by eight components in which “fuel supply” unit is parallel to “renewable sources” unit and “power conditioning” unit is parallel to “energy storage” unit. System behaviour is observed by numerical results of reliability and mean time to failure in neutrosophic environments at various time instants under data uncertainty. The innovation of proposed work is combination of neutrosophic sets with U.G.F and weibull based reliability framework to handle uncertainty effectively by comparing with conventional fuzzy approaches. A comparative analysis which based on reduction study and reliability by triangular fuzzy number (TFN), is performed in this study. A sensitivity analysis is also performed. The comparative analysis as uncertainty b1111ands highlighted graphically. The conclusion of current study is neutrosophic reliability framework effectively capturing uncertainty, indeterminacy, and falsity as compared to traditional reliability framework or fuzzy based approaches in power generation system.
SN  - 2662-9984
ER  -