Skip to content
DraconiticResearch
Search Sources API
190,869 studies31 sourcesUpdated 31 min ago
Peer-reviewedCC BYJournal of Cardiovascular Magnetic Resonance

Simultaneous multi slice (SMS) balanced steady state free precession first-pass myocardial perfusion cardiovascular magnetic resonance with iterative reconstruction at 1.5 T

Abstract

BACKGROUND: Simultaneous-Multi-Slice (SMS) perfusion imaging has the potential to acquire multiple slices, increasing myocardial coverage without sacrificing in-plane spatial resolution. To maximise signal-to-noise ratio (SNR), SMS can be combined with a balanced steady state free precession (bSSFP) readout. Furthermore, application of gradient-controlled local Larmor adjustment (GC-LOLA) can ensure robustness against off-resonance artifacts and SNR loss can be mitigated by applying iterative reconstruction with spatial and temporal regularisation. The objective of this study was to compare cardiovascular magnetic resonance (CMR) myocardial perfusion imaging using SMS bSSFP imaging with GC-LOLA and iterative reconstruction to 3 slice bSSFP. METHODS: ) regularisation parameters. Qualitative ratings of overall image quality (0 = poor image quality, 1 = major artifact, 2 = minor artifact, 3 = excellent), perceived SNR (0 = poor SNR, 1 = major noise, 2 = minor noise, 3 = high SNR), frequency of sequence related artifacts and patient related artifacts were undertaken. Quantitative analysis of contrast ratio (CR) and percentage of dark rim artifact (DRA) was performed. RESULTS: 0.005) was identified as the optimal reconstruction with the highest overall image quality, least sequence related artifact and higher perceived SNR. SMS-iter 6 had superior overall image quality (2.50 ± 0.53 vs 1.50 ± 0.53, p = 0.005) and perceived SNR (2.25 ± 0.46 vs 0.75 ± 0.46, p = 0.010) compared to 3 slice bSSFP. There were no significant differences in sequence related artifact, CR (3.62 ± 0.39 vs 3.66 ± 0.65, p = 0.88) or percentage of DRA (5.25 ± 6.56 vs 4.25 ± 4.30, p = 0.64) with SMS-iter 6 compared to 3 slice bSSFP. CONCLUSIONS: SMS bSSFP with GC-LOLA and iterative reconstruction improved image quality compared to a 3 slice bSSFP with doubled spatial coverage and preserved in-plane spatial resolution. Future evaluation in patients with coronary artery disease is warranted.

Related

  1. Simultaneous multi-slice steady-state free precession myocardial perfusion with iterative reconstruction and integrated motion compensation
    Sarah Mcelroy, Karl Kunze, Muhummad Sohaib Nazir +8
    European Journal of RadiologyPeer-reviewedCC BYFull text7 citedSystems & synthetic biologyHAL
  2. Three-dimensional motion corrected free-breathing simultaneous multislice-balanced steady state free precession myocardium perfusion imaging
    Naledi Adam, Ronald Mooiweer, Andrew Tyler +10
    Journal of Cardiovascular Magnetic ResonancePeer-reviewedCC BYSystems & synthetic biologyHAL
  3. Quantitative Myocardial Perfusion With Simultaneous-Multislice Stress CMR for Detection of Significant Coronary Artery Disease
    Muhummad Sohaib Nazir, Xenios Milidonis, Sarah Mcelroy +13
    JACC: Cardiovascular ImagingPeer-reviewedLicence not statedFull text9 citedSystems & synthetic biologyHAL
  4. WITHDRAWN: Segmental Variability of Bolus-dispersion-induced Myocardial Blood Flow in Quantitative Myocardial Perfusion MRI: A CFD-based Analysis
    T. A. Jedamzik, J. Martens, M. Siebes +2
    bioRxivPreprintAll rights reservedFull textSystems & synthetic biologybioRxiv
  5. Atrial fibrillation is independently associated with impaired myocardial perfusion
    Niklas Vartiainen, Suvi Hartikainen, Antti-Pekka E. Rissanen +7
    PLOS OnePeer-reviewedCC BY 4.0Full textNeuroscienceCardiovascular medicinePLOSPMC
BibTeX
@article{nazir2026simultaneous,
  title = {{Simultaneous multi slice (SMS) balanced steady state free precession first-pass myocardial perfusion cardiovascular magnetic resonance with iterative reconstruction at 1.5 T}},
  author = {Muhummad Sohaib Nazir and Radhouene Neji and Peter Speier and Fiona Reid and Daniel Stäb and Michaela Schmidt and Christoph Forman and Reza Razavi and Sven Plein and Tevfik Ismail and Amedeo Chiribiri and Sébastien Roujol},
  journal = {Journal of Cardiovascular Magnetic Resonance},
  year = {2026},
  month = oct,
  doi = {10.1186/s12968-018-0502-7},
  url = {https://hal.science/hal-05796039v1},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - Simultaneous multi slice (SMS) balanced steady state free precession first-pass myocardial perfusion cardiovascular magnetic resonance with iterative reconstruction at 1.5 T
AU  - Muhummad Sohaib Nazir
AU  - Radhouene Neji
AU  - Peter Speier
AU  - Fiona Reid
AU  - Daniel Stäb
AU  - Michaela Schmidt
AU  - Christoph Forman
AU  - Reza Razavi
AU  - Sven Plein
AU  - Tevfik Ismail
AU  - Amedeo Chiribiri
AU  - Sébastien Roujol
PY  - 2026
DA  - 2026/10/12
JO  - Journal of Cardiovascular Magnetic Resonance
DO  - 10.1186/s12968-018-0502-7
UR  - https://hal.science/hal-05796039v1
AB  - BACKGROUND: Simultaneous-Multi-Slice (SMS) perfusion imaging has the potential to acquire multiple slices, increasing myocardial coverage without sacrificing in-plane spatial resolution. To maximise signal-to-noise ratio (SNR), SMS can be combined with a balanced steady state free precession (bSSFP) readout. Furthermore, application of gradient-controlled local Larmor adjustment (GC-LOLA) can ensure robustness against off-resonance artifacts and SNR loss can be mitigated by applying iterative reconstruction with spatial and temporal regularisation. The objective of this study was to compare cardiovascular magnetic resonance (CMR) myocardial perfusion imaging using SMS bSSFP imaging with GC-LOLA and iterative reconstruction to 3 slice bSSFP. METHODS: ) regularisation parameters. Qualitative ratings of overall image quality (0 = poor image quality, 1 = major artifact, 2 = minor artifact, 3 = excellent), perceived SNR (0 = poor SNR, 1 = major noise, 2 = minor noise, 3 = high SNR), frequency of sequence related artifacts and patient related artifacts were undertaken. Quantitative analysis of contrast ratio (CR) and percentage of dark rim artifact (DRA) was performed. RESULTS: 0.005) was identified as the optimal reconstruction with the highest overall image quality, least sequence related artifact and higher perceived SNR. SMS-iter 6 had superior overall image quality (2.50 ± 0.53 vs 1.50 ± 0.53, p = 0.005) and perceived SNR (2.25 ± 0.46 vs 0.75 ± 0.46, p = 0.010) compared to 3 slice bSSFP. There were no significant differences in sequence related artifact, CR (3.62 ± 0.39 vs 3.66 ± 0.65, p = 0.88) or percentage of DRA (5.25 ± 6.56 vs 4.25 ± 4.30, p = 0.64) with SMS-iter 6 compared to 3 slice bSSFP. CONCLUSIONS: SMS bSSFP with GC-LOLA and iterative reconstruction improved image quality compared to a 3 slice bSSFP with doubled spatial coverage and preserved in-plane spatial resolution. Future evaluation in patients with coronary artery disease is warranted.
SN  - 1097-6647
SN  - 1532-429X
ER  -