Intraoperative 180° rotation of a polyethylene liner during revision total hip arthroplasty for a Vancouver B2 periprosthetic femoral fracture: a case report

  1. 1Service de Chirurgie Orthopédique, Centre Chirurgical Émile Gallé, CHRU Nancy, Nancy, France
  2. 2Chirurgie orthopédique et traumatologique, Centre Chirurgical Emile Gallé CHRU de Nancy, Nancy, France

Abstract

Introduction and importance:: Revision total hip arthroplasty (RTHA) for periprosthetic femoral fractures in very elderly and frail patients is associated with substantial perioperative morbidity. When the acetabular component is well-fixed and correctly oriented, avoiding acetabular revision may reduce operative time, blood loss, and complication rates. We report an original intraoperative salvage technique consisting of a 180° rotation of a worn polyethylene (PE) liner.

Presentation of the case:: A 91-year-old woman sustained a Vancouver B2 periprosthetic femoral fracture around a loosened cemented stem. Preoperative imaging showed a well-fixed, correctly oriented cementless acetabular shell with marked asymmetric PE wear and periacetabular osteolysis, without loosening. During revision surgery, the femoral component was revised while the acetabular shell was retained. As no compatible replacement liner was available, the PE insert was removed, rotated by 180° to reposition the unworn sector into the weight-bearing posterosuperior zone, and re-impacted with an intact locking mechanism.

Clinical discussion:: In selected elderly and high-risk patients presenting with a stable metal-backed cup, a preserved locking mechanism, and asymmetric liner wear, isolated liner management may represent a reasonable alternative to full acetabular revision. Liner rotation allows the preservation of bone stock and the avoidance of the morbidity associated with acetabular extraction.

Conclusion:: Intraoperative 180° rotation of a PE liner may be considered an exceptional salvage option during RTHA for periprosthetic femoral fractures in carefully selected patients, when acetabular revision is deemed excessively risky.

Related

  1. Locking plate fixation with cerclage augmentation and bone grafting for Vancouver B2 periprosthetic femoral fractures around cementless stems: a surgical option in elderly high-risk patients unsuitable for revision arthroplasty (mid-term outcomes).
    Xingyu Shan, Zhimin Tian, Hongda Wang +7
    Frontiers in surgeryPeer-reviewedCC BYFull textSurgery & anaesthesiaEurope PMCPMC
  2. Culture-Specific Outcomes of Intra-Articular Antibiotic Infusion With Implant-Retaining Debridement for Periprosthetic Joint Infection After Unicompartmental Knee Arthroplasty
    Arthroplasty todayPeer-reviewedCC BY-NC-NDFull textSurgery & anaesthesiaEurope PMC
  3. From Measured Accuracy to Patient Outcome: Navigation in Total Hip Arthroplasty and Molecular Diagnosis of Periprosthetic Joint Infection: A Narrative Review
    Diagnostics (Basel, Switzerland)Peer-reviewedCC BYFull textGeneral medicineEurope PMC
  4. Extensor Mechanism Reconstruction Following Periprosthetic Joint Infection After Total Knee Arthroplasty: A Systematic Review
    Camilla Prosenz, Hisham Fansa, Hannah Engel +3
    CureusPeer-reviewedCC BYFull textGeneral medicineEurope PMC
  5. Implant sonication supporting the diagnosis of low-grade periprosthetic joint infection following reverse shoulder arthroplasty: a case report
    Gi-Won Seo, Kunil Seo, Yong-Beom Kim
    Frontiers in medicinePeer-reviewedCC BYFull textGeneral medicineEurope PMC
BibTeX
@article{barbaret2026intraoperative,
  title = {{Intraoperative 180° rotation of a polyethylene liner during revision total hip arthroplasty for a Vancouver B2 periprosthetic femoral fracture: a case report}},
  author = {Arthur Barbaret and Maxime Lefevre and Florian Collignon and Anne Lise Bernel and Joseph Jacquet and Olivier Roche},
  journal = {International Journal of Surgery Case Reports},
  year = {2026},
  month = sep,
  doi = {10.1097/rc9.0000000000001017},
  url = {https://doi.org/10.1097/rc9.0000000000001017},
  note = {CC BY-NC-ND 4.0},
}
RIS
TY  - JOUR
TI  - Intraoperative 180° rotation of a polyethylene liner during revision total hip arthroplasty for a Vancouver B2 periprosthetic femoral fracture: a case report
AU  - Arthur Barbaret
AU  - Maxime Lefevre
AU  - Florian Collignon
AU  - Anne Lise Bernel
AU  - Joseph Jacquet
AU  - Olivier Roche
PY  - 2026
DA  - 2026/09/29
JO  - International Journal of Surgery Case Reports
DO  - 10.1097/rc9.0000000000001017
UR  - https://doi.org/10.1097/rc9.0000000000001017
AB  - Introduction and importance:: Revision total hip arthroplasty (RTHA) for periprosthetic femoral fractures in very elderly and frail patients is associated with substantial perioperative morbidity. When the acetabular component is well-fixed and correctly oriented, avoiding acetabular revision may reduce operative time, blood loss, and complication rates. We report an original intraoperative salvage technique consisting of a 180° rotation of a worn polyethylene (PE) liner.  Presentation of the case:: A 91-year-old woman sustained a Vancouver B2 periprosthetic femoral fracture around a loosened cemented stem. Preoperative imaging showed a well-fixed, correctly oriented cementless acetabular shell with marked asymmetric PE wear and periacetabular osteolysis, without loosening. During revision surgery, the femoral component was revised while the acetabular shell was retained. As no compatible replacement liner was available, the PE insert was removed, rotated by 180° to reposition the unworn sector into the weight-bearing posterosuperior zone, and re-impacted with an intact locking mechanism.  Clinical discussion:: In selected elderly and high-risk patients presenting with a stable metal-backed cup, a preserved locking mechanism, and asymmetric liner wear, isolated liner management may represent a reasonable alternative to full acetabular revision. Liner rotation allows the preservation of bone stock and the avoidance of the morbidity associated with acetabular extraction.  Conclusion:: Intraoperative 180° rotation of a PE liner may be considered an exceptional salvage option during RTHA for periprosthetic femoral fractures in carefully selected patients, when acetabular revision is deemed excessively risky.