Skip to content
DraconiticResearch
Search Sources API
276,906 studies31 sourcesUpdated 26 min ago
Peer-reviewedCC BYFrontiers in surgery

Locking plate fixation with cerclage augmentation and bone grafting for Vancouver B2 periprosthetic femoral fractures around cementless stems: a surgical option in elderly high-risk patients unsuitable for revision arthroplasty (mid-term outcomes).

  1. 1The Joint Surgery Department of the 940th Hospital of the People's Liberation Army General Logistics Department, Lanzhou, Gansu, China.
  2. 2Gansu University of Chinese Medicine, Lanzhou, Gansu, China.

Abstract

Objective

To evaluate the mid-term clinical and radiographic outcomes of open reduction and internal fixation (ORIF) with a locking plate, cerclage wires, and bone grafting for Vancouver B2 periprosthetic femoral fractures (PFF) in elderly, high-risk patients who are unsuitable for revision arthroplasty after primary cementless total hip arthroplasty (THA).Methods

A retrospective analysis was conducted on 28 elderly patients with Vancouver B2 PFFs treated with locking plate fixation and cerclage wiring. Patient demographics, operative parameters (time, blood loss), and hospital stay were recorded. Fracture healing time, Harris Hip Score (HHS), and Visual Analog Scale (VAS) were evaluated preoperatively and at the final follow-up, with VAS also assessed postoperatively. Complications were documented.Results

The mean follow-up was 63.86 months (range, 24-120). During the follow-up period, three patients died due to advanced age, and two patients were lost to follow-up because of changes in contact information or failure to attend scheduled visits. Mean operative time was 176.32 ± 20.46 min, and mean blood loss was 358.93 ± 188.59 mL. All fractures united, with a mean healing time of 3.89 months. HHS improved significantly from 43.93 preoperatively to 90.32 at final follow-up (P < 0.001), and VAS decreased from 4.11 ± 1.03 to 0.43 ± 0.50 (P < 0.001). Postoperative DVT occurred in 7 patients (mean onset: 7.71 ± 1.11 days), including one case progressing to pulmonary embolism requiring an inferior vena cava filter; all were successfully managed with rivaroxaban. Prosthesis subsidence was observed in 5 patients, of whom 3 remained stable and were monitored, while 2 with delayed union underwent revision with distally fixed cementless stems. No other complications (infection, nonunion, implant failure, loosening, or osteolysis) were observed in the remaining patients. Kaplan-Meier analysis, with revision as the endpoint, estimated a 5-year survival rate of 92.3% (95% CI, 73.8%∼97.9%).Conclusion

For selected high-risk elderly patients with Vancouver B2 PFF who are unsuitable for revision arthroplasty, ORIF with locking plate, cerclage wires, and bone grafting appears to be a potentially viable treatment option. Its success depends on rigorous case selection and standardized perioperative management, and further long-term prospective studies are warranted to confirm its durability.

Related

  1. The Effect of Cementless Stem Design on Late Periprosthetic Fractures After Total Hip Arthroplasty. Does the Design of Cementless Stems Affects the Rate of Periprosthetic Femoral Fractures?
    Antonios A. Koutalos, MD, PhD, Vasileios Akrivos, MD, Nifon Gkekas, MD +1
    Arthroplasty TodayPeer-reviewedCC BY-NC-ND 4.0Full textSurgery & anaesthesiaDOAJPMC
  2. Intraoperative 180° rotation of a polyethylene liner during revision total hip arthroplasty for a Vancouver B2 periprosthetic femoral fracture: a case report
    Arthur Barbaret, Maxime Lefevre, Florian Collignon +3
    International Journal of Surgery Case ReportsPeer-reviewedCC BY-NC-ND 4.0Full textSurgery & anaesthesiaPMCEurope PMC
  3. Fracture Morphology and Extraction-Related Femoral Damages in Short Versus Standard Cementless Stems: Analyses of Vancouver B2 Fractures and Well-Fixed Nonfracture Revisions
    Dominic Simon, Gautier Beckers, Florian Pachmann +5
    Arthroplasty todayPeer-reviewedCC BYFull textSurgery & anaesthesiaEurope PMC
  4. Early Revision Rates and Clinical Outcomes of Two Cementless Cruciate-Retaining Total Knee Arthroplasty Designs at Two-Year Follow-Up: A Propensity Score-Adjusted Comparative Analysis
    Medicina (Kaunas, Lithuania)Peer-reviewedCC BYFull textGeneral medicineEurope PMC
  5. Twenty-Year Wear Progression and Long-Term Outcomes of Conventional Polyethylene Liners After Cementless Total Hip Arthroplasty
    Yasutaka Watanabe, Toru Moro, Hisatoshi Ishikura +3
    Arthroplasty todayPeer-reviewedCC BY-NC-NDFull textSurgery & anaesthesiaEurope PMC
BibTeX
@article{shan2026locking,
  title = {{Locking plate fixation with cerclage augmentation and bone grafting for Vancouver B2 periprosthetic femoral fractures around cementless stems: a surgical option in elderly high-risk patients unsuitable for revision arthroplasty (mid-term outcomes).}},
  author = {Xingyu Shan and Zhimin Tian and Hongda Wang and Huanxi Li and Jialong Lu and Zili Feng and Ruiling Xu and Yongjie Qiao and Shenghu Zhou and Haoqiang Zhang},
  journal = {Frontiers in surgery},
  year = {2026},
  month = nov,
  doi = {10.3389/fsurg.2026.1942011},
  url = {https://europepmc.org/article/MED/43054415},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - Locking plate fixation with cerclage augmentation and bone grafting for Vancouver B2 periprosthetic femoral fractures around cementless stems: a surgical option in elderly high-risk patients unsuitable for revision arthroplasty (mid-term outcomes).
AU  - Xingyu Shan
AU  - Zhimin Tian
AU  - Hongda Wang
AU  - Huanxi Li
AU  - Jialong Lu
AU  - Zili Feng
AU  - Ruiling Xu
AU  - Yongjie Qiao
AU  - Shenghu Zhou
AU  - Haoqiang Zhang
PY  - 2026
DA  - 2026/11/04
JO  - Frontiers in surgery
DO  - 10.3389/fsurg.2026.1942011
UR  - https://europepmc.org/article/MED/43054415
AB  - Objective  To evaluate the mid-term clinical and radiographic outcomes of open reduction and internal fixation (ORIF) with a locking plate, cerclage wires, and bone grafting for Vancouver B2 periprosthetic femoral fractures (PFF) in elderly, high-risk patients who are unsuitable for revision arthroplasty after primary cementless total hip arthroplasty (THA).Methods  A retrospective analysis was conducted on 28 elderly patients with Vancouver B2 PFFs treated with locking plate fixation and cerclage wiring. Patient demographics, operative parameters (time, blood loss), and hospital stay were recorded. Fracture healing time, Harris Hip Score (HHS), and Visual Analog Scale (VAS) were evaluated preoperatively and at the final follow-up, with VAS also assessed postoperatively. Complications were documented.Results  The mean follow-up was 63.86 months (range, 24-120). During the follow-up period, three patients died due to advanced age, and two patients were lost to follow-up because of changes in contact information or failure to attend scheduled visits. Mean operative time was 176.32 ± 20.46 min, and mean blood loss was 358.93 ± 188.59 mL. All fractures united, with a mean healing time of 3.89 months. HHS improved significantly from 43.93 preoperatively to 90.32 at final follow-up (P < 0.001), and VAS decreased from 4.11 ± 1.03 to 0.43 ± 0.50 (P < 0.001). Postoperative DVT occurred in 7 patients (mean onset: 7.71 ± 1.11 days), including one case progressing to pulmonary embolism requiring an inferior vena cava filter; all were successfully managed with rivaroxaban. Prosthesis subsidence was observed in 5 patients, of whom 3 remained stable and were monitored, while 2 with delayed union underwent revision with distally fixed cementless stems. No other complications (infection, nonunion, implant failure, loosening, or osteolysis) were observed in the remaining patients. Kaplan-Meier analysis, with revision as the endpoint, estimated a 5-year survival rate of 92.3% (95% CI, 73.8%∼97.9%).Conclusion  For selected high-risk elderly patients with Vancouver B2 PFF who are unsuitable for revision arthroplasty, ORIF with locking plate, cerclage wires, and bone grafting appears to be a potentially viable treatment option. Its success depends on rigorous case selection and standardized perioperative management, and further long-term prospective studies are warranted to confirm its durability.
SN  - 2296-875X
ER  -