Abstract

Inlet design assumes that supply air from side-wall inlets mixes with house air over several metres, but whether this holds in a densely caged multi-tier house, where cages and birds obstruct the jet, is untested. The bird-zone environment of a commercial stacked-cage house was measured with 24 in-cage sensors at three distances and two tiers over ten winter days. Three of four groups showed no resolvable cooling gradient at 1.5 m; only one north-side group cooled with distance, strengthening with ventilation (0.30 K per percent, R² = 0.39), while another showed the opposite sign. Every fitted decay coefficient (αdh=0 to 0.004) lay below the free-jet design range (0.01-0.03), by five or more times over the window. Vertical stratification of 0.78 K dominated (side × tier p<0.001): the upper tier was up to 2.4 K warmer on the north side, while the south-side tiers differed by under 0.5 K. Shading nets lowered north-side inlet temperature by 0.80 K but warmed the south side. The practical consequence is that the thermal environment is organised by tier and side rather than by near-inlet distance, so monitoring, control and welfare-oriented assessment should target tiers and sides.

Related

  1. Effects of Cyclic High Ambient Temperature on Tricarboxylic Acid Cycle Intermediates and Orotate Levels in the Liver and Breast Muscle of Broiler Chickens
    Ayumi Katafuchi, Saki Shimamoto, Shozo Tomonaga +4
    The Journal of Poultry SciencePeer-reviewedCC BY-NC-SA 4.0Full textZoology & animal behaviourPMC
  2. First survey on the occurrence, subtype distribution and circulation of the enteric protozoan Blastocystis sp. in French broiler chicken farms
    Constance Denoyelle, Laetitia Bonifait, Nausicaa Gantois +14
    Poultry SciencePeer-reviewedCC BY 4.0Full text1 citedGeneral biologyEnvironmental science & pollutionHALHAL
  3. The Ecological Price of Segregation: Socioeconomic Stratification Structures Urban Bird and Vegetation Distribution
    Rodrigo Mutis, Sara Gabriela Acosta-Morales
    EcoEvoRxivPreprintCC BY 4.0Full textEcologyEcoEvoRxiv
  4. A general-purpose multi-path stacked coupling for stochastic reaction networks
    David F. Anderson, Jingyi Ma
  5. Preliminary association between infectious bronchitis virus viral load and the tracheal microbiome of broiler chickens
    Mohammad Bani-Amer, Seif Hundam, Mustafa Ababneh +4
    VirusDiseasePeer-reviewedLicence not statedFull text1 citedZoology & animal behaviourPMC
BibTeX
@article{wei2026temperature,
  title = {{Temperature Distribution and Vertical Stratification near Side-Wall Inlets of Stacked Cage Broiler Houses in Winter.}},
  author = {Yongxiang Wei and Wenjia Li and Quanyou Sun and Shaoyu Li and Bin Xu},
  journal = {Veterinary sciences},
  year = {2026},
  month = oct,
  doi = {10.3390/vetsci13101103},
  url = {https://europepmc.org/article/MED/42944197},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - Temperature Distribution and Vertical Stratification near Side-Wall Inlets of Stacked Cage Broiler Houses in Winter.
AU  - Yongxiang Wei
AU  - Wenjia Li
AU  - Quanyou Sun
AU  - Shaoyu Li
AU  - Bin Xu
PY  - 2026
DA  - 2026/10/16
JO  - Veterinary sciences
DO  - 10.3390/vetsci13101103
UR  - https://europepmc.org/article/MED/42944197
AB  - Inlet design assumes that supply air from side-wall inlets mixes with house air over several metres, but whether this holds in a densely caged multi-tier house, where cages and birds obstruct the jet, is untested. The bird-zone environment of a commercial stacked-cage house was measured with 24 in-cage sensors at three distances and two tiers over ten winter days. Three of four groups showed no resolvable cooling gradient at 1.5 m; only one north-side group cooled with distance, strengthening with ventilation (0.30 K per percent, R² = 0.39), while another showed the opposite sign. Every fitted decay coefficient (αdh=0 to 0.004) lay below the free-jet design range (0.01-0.03), by five or more times over the window. Vertical stratification of 0.78 K dominated (side × tier p<0.001): the upper tier was up to 2.4 K warmer on the north side, while the south-side tiers differed by under 0.5 K. Shading nets lowered north-side inlet temperature by 0.80 K but warmed the south side. The practical consequence is that the thermal environment is organised by tier and side rather than by near-inlet distance, so monitoring, control and welfare-oriented assessment should target tiers and sides.
SN  - 2306-7381
ER  -