Mo-Decorated Cu₂O Nanozyme with Enhanced Peroxidase-like Activity for Colorimetric Detection of H₂O₂ and Glucose.

  1. 1College of Animal Science and Technology, Sichuan Agricultural University, Chengdu 611130, China.
  2. 2College of Science, Sichuan Agricultural University, Chengdu 611130, China.

Abstract

A molybdenum-decorated cuprous oxide (Cu₂O@Mo) nanozyme with markedly enhanced peroxidase-mimetic activity was rationally constructed for the colorimetric quantification of H₂O₂ and glucose in human serum. Mo decoration is proposed to modulate the electronic structure of Cu₂O and provide coordinatively unsaturated sites, which are considered to substantially elevate the peroxidase-like performance. Under optimized conditions (pH 6.0, 40 °C), the Cu₂O@Mo-TMB colorimetric system affords a linear response to H₂O₂ over 10-90 μM with a limit of detection (LOD) of 1.24 μM, and to glucose over 0.02-0.25 mM with an LOD of 3.5 μM when integrated with a glucose oxidase (GOx)-mediated cascade reaction. The sensor also exhibits high selectivity toward both analytes in the presence of common serum interferents, including metal ions, anions, and amino acids. When applied to human serum samples, the serum glucose measurements were in agreement with the hospital hexokinase reference method, whereas the H₂O₂ performance in the processed serum matrix was assessed by spike-recovery, as the endogenous level is below the LOD. This simple, low-cost, and sensitive colorimetric platform shows promise for glucose determination in biological samples.

Related

  1. The Au–CeO2 Nanozyme with Enhanced Peroxidase-like Activity for Highly Sensitive Ratiometric Colorimetric Detection of Nitrite
    Luyu Chen, Wenting Lu, Chunyan Sun +6
    FoodsPeer-reviewedCC BY 4.0Full textMaterials & polymersPMC
  2. Peroxidase-like activity of a POSS-based Cu(I) coordination polymer for colorimetric uric acid detection
    Arosmit Mohanty, Anrudh Mishra, Lydie Viau +2
    Microchemical JournalPeer-reviewedCC BY-NC 4.0Full textMaterials & polymersHAL
  3. Nanozyme-Based Colorimetric Sensing of Hexavalent Chromium with Advances in Material Design and Practical Detection
    Zhen Chen, Tingyuan Zheng, Ruiqi Ma +3
    MoleculesPeer-reviewedCC BY 4.0General chemistryCrossref
  4. Peroxidase-mimetic, electrochemically active, Co3O4-decorated pectic acid-based polyacrylate derivatives for rapid and sensitive hydrogen peroxide detection in apple juice samples
    M. S. Hashem, Hend S. Magar
    RSC AdvancesPeer-reviewedCC BY-NC 3.0Full textGeneral chemistryPMC
  5. Evaluation of a Peroxidase-Mimetic Berberine-Hemin Nanozyme for Effective Antibacterial Treatment of Periodontal Diseases
    Shiqiang Zhao, Mengwen Wang, Xiangzhi Cui +4
    International Journal of NanomedicinePeer-reviewedCC BY-NC 4.0Full textMaterials & polymersPMC
BibTeX
@article{lei2026modecorated,
  title = {{Mo-Decorated Cu₂O Nanozyme with Enhanced Peroxidase-like Activity for Colorimetric Detection of H₂O₂ and Glucose.}},
  author = {Mijia Lei and Dongxu Cheng and Xianxiang Wang},
  journal = {Biosensors},
  year = {2026},
  month = nov,
  doi = {10.3390/bios16110670},
  url = {https://europepmc.org/article/MED/43082565},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - Mo-Decorated Cu₂O Nanozyme with Enhanced Peroxidase-like Activity for Colorimetric Detection of H₂O₂ and Glucose.
AU  - Mijia Lei
AU  - Dongxu Cheng
AU  - Xianxiang Wang
PY  - 2026
DA  - 2026/11/19
JO  - Biosensors
DO  - 10.3390/bios16110670
UR  - https://europepmc.org/article/MED/43082565
AB  - A molybdenum-decorated cuprous oxide (Cu₂O@Mo) nanozyme with markedly enhanced peroxidase-mimetic activity was rationally constructed for the colorimetric quantification of H₂O₂ and glucose in human serum. Mo decoration is proposed to modulate the electronic structure of Cu₂O and provide coordinatively unsaturated sites, which are considered to substantially elevate the peroxidase-like performance. Under optimized conditions (pH 6.0, 40 °C), the Cu₂O@Mo-TMB colorimetric system affords a linear response to H₂O₂ over 10-90 μM with a limit of detection (LOD) of 1.24 μM, and to glucose over 0.02-0.25 mM with an LOD of 3.5 μM when integrated with a glucose oxidase (GOx)-mediated cascade reaction. The sensor also exhibits high selectivity toward both analytes in the presence of common serum interferents, including metal ions, anions, and amino acids. When applied to human serum samples, the serum glucose measurements were in agreement with the hospital hexokinase reference method, whereas the H₂O₂ performance in the processed serum matrix was assessed by spike-recovery, as the endogenous level is below the LOD. This simple, low-cost, and sensitive colorimetric platform shows promise for glucose determination in biological samples.
SN  - 2079-6374
ER  -