Skip to content
DraconiticResearch
Search Sources API
203,234 studies31 sourcesUpdated 32 min ago
Peer-reviewedCC BY-NCEuropean heart journal. Digital health

AI-enabled OPM-magnetocardiography for pre-angiography infarct-related artery probability estimation in NSTEMI: a two-campus prospective cohort study

7 affiliations
  1. 1Department of Cardiology, Beijing Anzhen Hospital, Capital Medical University, No. 2 Anzhen Road, Chaoyang District, Beijing 100029, China.
  2. 2Arrhythmia Center, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100037, China.
  3. 3Department of Cardiovascular Surgery, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100037, China.
  4. 4Department of Cardiac Surgery, Beijing Anzhen Hospital, Capital Medical University, Beijing 100029, China.
  5. 5Beijing X-MAGTECH Technology Co., Ltd, Beijing 100096, China.
  6. 6School of Instrumentation Science and Opto-electronics Engineering, Beihang University, Beijing 100191, China.
  7. 7Department of Cardiology, Beijing Friendship Hospital, Capital Medical University, No. 95 Yong'an Road, Xicheng District, Beijing 100050, China.

Abstract

Aims

Identifying the infarct-related artery (IRA) before coronary angiography in non-ST-segment elevation myocardial infarction (NSTEMI) is difficult because current approaches have limited sensitivity. We evaluated whether a non-invasive 90-s optically pumped magnetometer magnetocardiography (OPM-MCG) recording can estimate pre-angiography IRA probabilities in these patients and provide information beyond standard-care variables.Methods and results

This prospective two-campus study within one hospital system included a Campus 1 development cohort (n = 493) and a geographically separate Campus 2 test cohort (n = 118). All patients underwent OPM-MCG before angiography. An XGBoost model using 65 prespecified OPM-MCG features was developed with nested cross-validation, locked, and evaluated once in Campus 2. IRA adjudication followed a core-laboratory hierarchy. Discrimination, calibration, and clinical utility were compared with ECG and TTE. Among 611 patients, 43% had LAD, 23% LCx, and 34% RCA IRA. In Campus 2, overall accuracy was 63.6%, macro-F1 was 60.0%; LAD/LCx/RCA vessel-specific areas under the receiver operating characteristic curve were 0.87/0.79/0.79 and top-1 sensitivity was 76.6%/34.5%/69.0%. Accuracy was 51.7% for matched ECG-only XGBoost and 55.9% for integrated standard care. In an exploratory stacked analysis, adding locked OPM-MCG probabilities to standard care increased accuracy to 67.8% (paired difference 11.9%, 95% CI 4.2-19.5; P = 0.008).Conclusion

In haemodynamically stable patients with NSTEMI already selected for invasive management, a locked OPM-MCG model provided informative vessel-level probabilities in Campus 2 and complementary signal with standard care. Performance was strongest for LAD and RCA. Prospective multicentre, cross-platform testing is needed before clinical use.Trial registration number

ChiCTR2300070211.

Related

  1. Global trends and knowledge structure of cardiovascular magnetocardiography research: a bibliometric analysis
    Yaxing He, Xu Zhang, Xiaole Han +4
    Frontiers in medicinePeer-reviewedCC BYFull textGeneral medicineEurope PMC
  2. HSPiP, computational, and thermodynamic models-based solubility validation of tofacitinib in PEG400 – water system, shelf-life estimation, and GastroPlus-enabled predictive in vivo performance
    Afzal Hussain, Zahid Rafiq, Iman Ehsan +2
    DARU Journal of Pharmaceutical SciencesPeer-reviewedLicence not statedFull textPharmacology & toxicologyPMC
  3. Imaging Correlation of Color Doppler Ultrasound, CT Angiography, and MR Angiography Findings in Extracranial Carotid and Vertebral Artery Disease Among Ischemic Stroke Patients: A Prospective Observational Study.
    Rashmi Singh, Mansi Patel, Kiran Katara +3
    CureusPeer-reviewedCC BYFull textGeneral medicineEurope PMC
  4. Diagnostic Accuracy and Feasibility of Quantitative Flow Ratio at Low Frame Rate Angiography: The Prospective Multicentre Australian AVALON Study
    Joseph M. O'Brien, Michael Zhang, Thomas J. Ford +11
    Catheterization and Cardiovascular InterventionsPeer-reviewedCC BY-NC 4.0Full textSurgery & anaesthesiaPMC
  5. Clinical Usefulness of Artificial Intelligence-Enabled Electrocardiography for Pulmonary Hypertension Detection: A Meta-analysis Based on Pre- and Post-Test Probability
    J. A. C. EDJIMBI, A. E. Kesaf, A. Gajjar +2
    medRxivPreprintCC BYFull textCardiovascular medicinemedRxiv
BibTeX
@article{liu2026aienabled,
  title = {{AI-enabled OPM-magnetocardiography for pre-angiography infarct-related artery probability estimation in NSTEMI: a two-campus prospective cohort study}},
  author = {Linqi Liu and Yilin Pan and Jie Ji and Hai Gao and Yanlong Ren and Min Zhang and Mingduo Zhang and Ming Ding and Chenchen Tu and Xiantao Song},
  journal = {European heart journal. Digital health},
  year = {2026},
  month = oct,
  doi = {10.1093/ehjdh/ztag161},
  url = {https://europepmc.org/article/PMC/PMC13718593},
  note = {CC BY-NC},
}
RIS
TY  - JOUR
TI  - AI-enabled OPM-magnetocardiography for pre-angiography infarct-related artery probability estimation in NSTEMI: a two-campus prospective cohort study
AU  - Linqi Liu
AU  - Yilin Pan
AU  - Jie Ji
AU  - Hai Gao
AU  - Yanlong Ren
AU  - Min Zhang
AU  - Mingduo Zhang
AU  - Ming Ding
AU  - Chenchen Tu
AU  - Xiantao Song
PY  - 2026
DA  - 2026/10/10
JO  - European heart journal. Digital health
DO  - 10.1093/ehjdh/ztag161
UR  - https://europepmc.org/article/PMC/PMC13718593
AB  - Aims  Identifying the infarct-related artery (IRA) before coronary angiography in non-ST-segment elevation myocardial infarction (NSTEMI) is difficult because current approaches have limited sensitivity. We evaluated whether a non-invasive 90-s optically pumped magnetometer magnetocardiography (OPM-MCG) recording can estimate pre-angiography IRA probabilities in these patients and provide information beyond standard-care variables.Methods and results  This prospective two-campus study within one hospital system included a Campus 1 development cohort (n = 493) and a geographically separate Campus 2 test cohort (n = 118). All patients underwent OPM-MCG before angiography. An XGBoost model using 65 prespecified OPM-MCG features was developed with nested cross-validation, locked, and evaluated once in Campus 2. IRA adjudication followed a core-laboratory hierarchy. Discrimination, calibration, and clinical utility were compared with ECG and TTE. Among 611 patients, 43% had LAD, 23% LCx, and 34% RCA IRA. In Campus 2, overall accuracy was 63.6%, macro-F1 was 60.0%; LAD/LCx/RCA vessel-specific areas under the receiver operating characteristic curve were 0.87/0.79/0.79 and top-1 sensitivity was 76.6%/34.5%/69.0%. Accuracy was 51.7% for matched ECG-only XGBoost and 55.9% for integrated standard care. In an exploratory stacked analysis, adding locked OPM-MCG probabilities to standard care increased accuracy to 67.8% (paired difference 11.9%, 95% CI 4.2-19.5; P = 0.008).Conclusion  In haemodynamically stable patients with NSTEMI already selected for invasive management, a locked OPM-MCG model provided informative vessel-level probabilities in Campus 2 and complementary signal with standard care. Performance was strongest for LAD and RCA. Prospective multicentre, cross-platform testing is needed before clinical use.Trial registration number  ChiCTR2300070211.
SN  - 2634-3916
ER  -