Bioequivalence study of two formulations of a sitagliptin/metformin hydrochloride extended-release tablet in healthy Chinese subjects under fasting and fed conditions: a randomized, open-label, single-dose, crossover trial
- 1Phase I Clinical Research Center, The Affiliated Hospital of Qingdao University
- 2Clinical Research Department, Qilu Pharmaceutical (Hainan) Co., Ltd.
Abstract
Introduction: This study aimed to evaluate the bioequivalence and safety of a newly developed generic sitagliptin/metformin hydrochloride extended‐release (XR) tablet (50 mg/500 mg) compared with the reference formulation, Janumet XR, in healthy Chinese subjects under fasting and fed conditions.
Methods: This randomized, open‐label, single‐dose, two‐period, two‐sequence crossover study included 40 subjects in the fasting cohort and 36 subjects in the fed cohort. Subjects received a single dose of the test or reference formulation in each period, separated by a 5‐day washout period. Plasma concentrations of sitagliptin and metformin were determined using a validated liquid chromatography‐tandem mass spectrometry method. Bioequivalence was assessed using the 90% confidence intervals (CIs) for the geometric mean ratios (GMRs; test/reference) of maximum plasma concentration (C max ), area under the plasma concentration‐time curve from time zero to the last quantifiable concentration (AUC 0‐t ), and area under the plasma concentration‐time curve from time zero to infinity (AUC 0‐infinity ).
Results: Under fasting conditions, the 90% CIs for the GMRs of sitagliptin for C max , AUC 0‐t , and AUC 0‐infinity were 88.24%–101.46%, 98.24%–103.15%, and 98.41%–103.33%, respectively. The corresponding values for metformin were 93.23%–103.26%, 93.00%–106.20%, and 92.89%–105.74%. Bioequivalence was also established under fed conditions for sitagliptin (C max : 88.29%–99.06%; AUC 0‐t : 96.19%–101.02%; AUC 0‐infinity : 96.07%–101.04%) and metformin (C max : 92.06% –99.39%; AUC 0‐t : 91.31%–100.06%; AUC 0‐infinity : 91.00%–99.30%). Analysis of variance showed a significant period effect for metformin AUC 0‐t and AUC 0‐infinity under fasting conditions (P < 0.05), whereas no significant formulation effect was observed (P > 0.05). Both formulations were well tolerated. Only Grade 1 or Grade 2 adverse events were reported, and no serious adverse events occurred
Discussion: The generic sitagliptin/metformin hydrochloride XR tablet was bioequivalent to the reference product under both fasting and fed conditions in healthy Chinese subjects. The generic formulation was well tolerated and may provide a safe and effective alternative for the treatment of type 2 diabetes mellitus.
Related
- Bioequivalence of tegomil fumarate gastro-resistant capsules versus dimethyl fumarate gastro-resistant capsules under different fed conditions: two randomized, crossover, phase I studies
- Development of an In Vitro Permeation Test Framework For Naloxone Hydrochloride Intranasal Spray: Establishing IVIVR for Bioequivalence Assessment
- Comparative evaluation of the antipyretic and analgesic efficacy and safety of a fast-release paracetamol 650 mg formulation vs. conventional paracetamol formulations in adults with acute febrile or febrile-pain conditions: a multicenter randomized controlled trial
- A Bioequivalence Study of Two Formulations of Enzalutamide Soft Capsules in Healthy Chinese Male Subjects.
- The role of sitagliptin in modifying metabolic, hormonal and clinical parameters in polycystic ovarian syndrome patients: a randomized controlled trial
BibTeX
@article{fang2026bioequivalence,
title = {{Bioequivalence study of two formulations of a sitagliptin/metformin hydrochloride extended-release tablet in healthy Chinese subjects under fasting and fed conditions: a randomized, open-label, single-dose, crossover trial}},
author = {Lin Fang and Xin Li and Rongxin Ban and Chenjing Wang and Yi Xu and Lipeng Xue and Ping Shi and Feifei Sun and Yu Cao},
journal = {Frontiers in Pharmacology},
year = {2026},
month = oct,
doi = {10.3389/fphar.2026.1927547},
url = {https://www.frontiersin.org/articles/10.3389/fphar.2026.1927547/full},
note = {CC BY 4.0},
}
RIS
TY - JOUR
TI - Bioequivalence study of two formulations of a sitagliptin/metformin hydrochloride extended-release tablet in healthy Chinese subjects under fasting and fed conditions: a randomized, open-label, single-dose, crossover trial
AU - Lin Fang
AU - Xin Li
AU - Rongxin Ban
AU - Chenjing Wang
AU - Yi Xu
AU - Lipeng Xue
AU - Ping Shi
AU - Feifei Sun
AU - Yu Cao
PY - 2026
DA - 2026/10/14
JO - Frontiers in Pharmacology
DO - 10.3389/fphar.2026.1927547
UR - https://www.frontiersin.org/articles/10.3389/fphar.2026.1927547/full
AB - Introduction: This study aimed to evaluate the bioequivalence and safety of a newly developed generic sitagliptin/metformin hydrochloride extended‐release (XR) tablet (50 mg/500 mg) compared with the reference formulation, Janumet XR, in healthy Chinese subjects under fasting and fed conditions. Methods: This randomized, open‐label, single‐dose, two‐period, two‐sequence crossover study included 40 subjects in the fasting cohort and 36 subjects in the fed cohort. Subjects received a single dose of the test or reference formulation in each period, separated by a 5‐day washout period. Plasma concentrations of sitagliptin and metformin were determined using a validated liquid chromatography‐tandem mass spectrometry method. Bioequivalence was assessed using the 90% confidence intervals (CIs) for the geometric mean ratios (GMRs; test/reference) of maximum plasma concentration (C max ), area under the plasma concentration‐time curve from time zero to the last quantifiable concentration (AUC 0‐t ), and area under the plasma concentration‐time curve from time zero to infinity (AUC 0‐infinity ). Results: Under fasting conditions, the 90% CIs for the GMRs of sitagliptin for C max , AUC 0‐t , and AUC 0‐infinity were 88.24%–101.46%, 98.24%–103.15%, and 98.41%–103.33%, respectively. The corresponding values for metformin were 93.23%–103.26%, 93.00%–106.20%, and 92.89%–105.74%. Bioequivalence was also established under fed conditions for sitagliptin (C max : 88.29%–99.06%; AUC 0‐t : 96.19%–101.02%; AUC 0‐infinity : 96.07%–101.04%) and metformin (C max : 92.06% –99.39%; AUC 0‐t : 91.31%–100.06%; AUC 0‐infinity : 91.00%–99.30%). Analysis of variance showed a significant period effect for metformin AUC 0‐t and AUC 0‐infinity under fasting conditions (P < 0.05), whereas no significant formulation effect was observed (P > 0.05). Both formulations were well tolerated. Only Grade 1 or Grade 2 adverse events were reported, and no serious adverse events occurred Discussion: The generic sitagliptin/metformin hydrochloride XR tablet was bioequivalent to the reference product under both fasting and fed conditions in healthy Chinese subjects. The generic formulation was well tolerated and may provide a safe and effective alternative for the treatment of type 2 diabetes mellitus.
SN - 1663-9812