Reliability-Aware Clinical Relation Learning for Uncertainty-Robust Multi-Label Chest X-ray Classification
- 1Sun Yat-sen University
Abstract
Background: Automated multi-label classification of chest radiographs is complicated by overlapping imaging findings, noisy report-derived labels, and changes in disease co-occurrence across clinical settings. Existing clinical-hierarchy methods can encode label relationships, but a rigid hierarchy may conflate categorical membership with empirical association and propagate annotation errors. Methods: We investigated Reliability-Aware Clinical Relation Learning (ReCaRL), a graph-assisted framework for multi-label chest radiograph classification. An image encoder produces initial finding scores, while a graph constructed from training-label associations provides reliability-weighted, confidence-gated updates. Uncertain annotations are handled with observation masks. The evaluation compares flat, weighted, graph-based, and hierarchy-penalty baselines, with internal and external discrimination and calibration assessments. Results: In the internal evaluation, ReCaRL achieved macro AUROC 0.821 and macro AUPRC 0.437, compared with 0.812 and 0.423 for the masked/weighted baseline. Mean AUROC across five common findings was 0.865 versus 0.858. External testing yielded AUROC 0.799 and AUPRC 0.409. Post-hoc calibration reduced the internal Brier score from 0.113 to 0.102 and the external expected calibration error from 0.082 to 0.061, without changing AUROC or AUPRC. Conclusions: Reliability-aware graph propagation and confidence gating were associated with modest improvements in multi-label chest radiograph classification relative to the matched masked/weighted baseline. Post-hoc calibration improved probability reliability in the reported evaluations. The findings do not establish a benefit in prospective clinical decision-making.
Related
- An uncertainty-aware multimodal deep learning framework for Alzheimer’s disease classification using MRI and electronic health records
- Interrater Reliability of Clinical Resting-State fMRI Network Classification: Comparison of Human Raters and an AI Algorithm
- Prospective validation of an uncertainty-aware machine learning model for secondary progressive multiple sclerosis classification
- High performance white blood cell classification using ensemble CNNs with Monte Carlo dropout and conformal prediction for clinical uncertainty quantification
- FedPCOS-XAI: a reliability-audited federated learning framework for polycystic ovary syndrome classification from ultrasound imaging
BibTeX
@misc{jin2026reliabilityaware,
title = {{Reliability-Aware Clinical Relation Learning for Uncertainty-Robust Multi-Label Chest X-ray Classification}},
author = {Y. Jin and T. Liu and m. stephen},
howpublished = {medRxiv},
year = {2026},
month = nov,
doi = {10.64898/2026.11.11.26367867},
url = {https://www.medrxiv.org/content/10.64898/2026.11.11.26367867v1},
note = {CC BY-NC},
}
RIS
TY - UNPB
TI - Reliability-Aware Clinical Relation Learning for Uncertainty-Robust Multi-Label Chest X-ray Classification
AU - Y. Jin
AU - T. Liu
AU - m. stephen
PY - 2026
DA - 2026/11/11
PB - medRxiv
DO - 10.64898/2026.11.11.26367867
UR - https://www.medrxiv.org/content/10.64898/2026.11.11.26367867v1
AB - Background: Automated multi-label classification of chest radiographs is complicated by overlapping imaging findings, noisy report-derived labels, and changes in disease co-occurrence across clinical settings. Existing clinical-hierarchy methods can encode label relationships, but a rigid hierarchy may conflate categorical membership with empirical association and propagate annotation errors. Methods: We investigated Reliability-Aware Clinical Relation Learning (ReCaRL), a graph-assisted framework for multi-label chest radiograph classification. An image encoder produces initial finding scores, while a graph constructed from training-label associations provides reliability-weighted, confidence-gated updates. Uncertain annotations are handled with observation masks. The evaluation compares flat, weighted, graph-based, and hierarchy-penalty baselines, with internal and external discrimination and calibration assessments. Results: In the internal evaluation, ReCaRL achieved macro AUROC 0.821 and macro AUPRC 0.437, compared with 0.812 and 0.423 for the masked/weighted baseline. Mean AUROC across five common findings was 0.865 versus 0.858. External testing yielded AUROC 0.799 and AUPRC 0.409. Post-hoc calibration reduced the internal Brier score from 0.113 to 0.102 and the external expected calibration error from 0.082 to 0.061, without changing AUROC or AUPRC. Conclusions: Reliability-aware graph propagation and confidence gating were associated with modest improvements in multi-label chest radiograph classification relative to the matched masked/weighted baseline. Post-hoc calibration improved probability reliability in the reported evaluations. The findings do not establish a benefit in prospective clinical decision-making.
ER -