Skip to content
DraconiticResearch
Search Sources API
276,906 studies31 sourcesUpdated 24 min ago
Peer-reviewedCC BYJournal of experimental orthopaedics

Can frontier vision‐language models support first‐pass orthopaedic landmark annotation? A zero‐shot technical feasibility study of 553 lateral knee radiographs

  1. 1Division of Orthopedic Surgery, Department of Surgery McMaster University Hamilton Ontario Canada.

Abstract

Purpose

Automated measurement of sagittal-plane knee parameters such as posterior tibial slope (PTS) and patellar height requires accurate anatomical landmark localization. Frontier vision-language models (VLMs) offer the potential to localize anatomical landmarks directly from textual definitions without task-specific training. This study evaluated the ability of GPT-5.5 to perform zero-shot landmark localization on lateral knee radiographs.Methods

A total of 553 lateral knee radiographs were manually annotated to create a human reference containing four anatomical structures: patella, tibial plateau, tibial shaft and tibial tubercle. GPT-5.5 was prompted using the OpenAI Application Programming Interface to generate annotations directly in YOLOv8 pose format. Model outputs underwent schema adherence validation prior to comparison with human annotations. Localization performance was quantified using Euclidean distance in both normalized coordinate space and pixel space. Computational performance metrics included token usage, runtime and cost.Results

GPT-5.5 successfully generated valid annotations for 552 of 553 radiographs, corresponding to schema validation success of 99.8%. Across 4416 landmark predictions, the mean (standard deviation [SD]) pixel localization error was 62.9 (69.3) pixels with a median (interquartile range) of 41.2 (23.1-77.3) pixels. Mean (SD) normalized localization error was 0.0376 (0.0325). The most accurately localized landmarks were the superior patellar pole (mean normalized error = 0.0240), inferior articular surface (0.0254) and inferior patellar pole (0.0259). Greater errors were observed for the distal tibial shaft (0.0561) and tibial tubercle (0.0515). Processing of all images cost $64.64 and required 11.9 h runtime.Conclusions

GPT-5.5 demonstrated the ability to localize anatomical landmarks on lateral knee radiographs using a zero-shot, definition-only prompting strategy with modest localization error. Although performance is insufficient for full independent deployment, VLMs show promise as first-pass annotation tools that may reduce the manual labelling burden associated with orthopaedic pose-estimation data sets.Level of evidence

Level IV.

Related

  1. AI-Based Automated Segmentation of the Mandibular Cortex and Mental Foramen for Radiomorphometric Measurement on Panoramic Radiographs: A Feasibility Study
    Sinem Atay Görür, Merve Önder, Özer Çelik +4
    Diagnostics (Basel, Switzerland)Peer-reviewedCC BYFull textGeneral medicineEurope PMC
  2. Videoautopsy—A Minimally Invasive Autopsy Method Using Endoscopic Techniques in Forensic Medicine: Technical Feasibility Study
    Diagnostics (Basel, Switzerland)Peer-reviewedCC BYFull textGeneral medicineEurope PMC
  3. Technical feasibility of synchronized multispectral dual-site optical sensing during vascular occlusion in an acute porcine flap model
    Devang Vyas, Jonathan Bova, Michel Saint-Cyr +2
    Scientific ReportsPeer-reviewedCC BY-NC-ND 4.0Full textMedical imaging & radiologyCrossref
  4. Technical validation and feasibility of video particle tracking for low-volume measurement of biliary micro-viscosity after liver transplantation
    Ludwig Lenz, Philip Friedrich, Peggy Stock +9
    Scientific ReportsPeer-reviewedCC BY 4.0Full textSurgery & anaesthesiaCrossref
  5. Transcatheter Valve-in-Band Implantation in a Swine Model of Failed Mitral Repair: A Technical Note and Proof of Feasibility
    Julia E. Katter, Jonathan Martinez Rivera, Meghan A. Matlack +4
    Journal of clinical medicinePeer-reviewedCC BYFull textCardiovascular medicineEurope PMCCrossref
BibTeX
@article{vivekanantha2026frontier,
  title = {{Can frontier vision‐language models support first‐pass orthopaedic landmark annotation? A zero‐shot technical feasibility study of 553 lateral knee radiographs}},
  author = {Prushoth Vivekanantha and Satyavenkata Kotipalli and Marc Daniel Bouchard and Ashraf Hantouly and Jeffrey Kay and Darren de Sa and Olufemi R Ayeni},
  journal = {Journal of experimental orthopaedics},
  year = {2026},
  month = oct,
  doi = {10.1002/jeo2.71007},
  url = {https://europepmc.org/article/PMC/PMC13794301},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - Can frontier vision‐language models support first‐pass orthopaedic landmark annotation? A zero‐shot technical feasibility study of 553 lateral knee radiographs
AU  - Prushoth Vivekanantha
AU  - Satyavenkata Kotipalli
AU  - Marc Daniel Bouchard
AU  - Ashraf Hantouly
AU  - Jeffrey Kay
AU  - Darren de Sa
AU  - Olufemi R Ayeni
PY  - 2026
DA  - 2026/10/01
JO  - Journal of experimental orthopaedics
DO  - 10.1002/jeo2.71007
UR  - https://europepmc.org/article/PMC/PMC13794301
AB  - Purpose  Automated measurement of sagittal-plane knee parameters such as posterior tibial slope (PTS) and patellar height requires accurate anatomical landmark localization. Frontier vision-language models (VLMs) offer the potential to localize anatomical landmarks directly from textual definitions without task-specific training. This study evaluated the ability of GPT-5.5 to perform zero-shot landmark localization on lateral knee radiographs.Methods  A total of 553 lateral knee radiographs were manually annotated to create a human reference containing four anatomical structures: patella, tibial plateau, tibial shaft and tibial tubercle. GPT-5.5 was prompted using the OpenAI Application Programming Interface to generate annotations directly in YOLOv8 pose format. Model outputs underwent schema adherence validation prior to comparison with human annotations. Localization performance was quantified using Euclidean distance in both normalized coordinate space and pixel space. Computational performance metrics included token usage, runtime and cost.Results  GPT-5.5 successfully generated valid annotations for 552 of 553 radiographs, corresponding to schema validation success of 99.8%. Across 4416 landmark predictions, the mean (standard deviation [SD]) pixel localization error was 62.9 (69.3) pixels with a median (interquartile range) of 41.2 (23.1-77.3) pixels. Mean (SD) normalized localization error was 0.0376 (0.0325). The most accurately localized landmarks were the superior patellar pole (mean normalized error = 0.0240), inferior articular surface (0.0254) and inferior patellar pole (0.0259). Greater errors were observed for the distal tibial shaft (0.0561) and tibial tubercle (0.0515). Processing of all images cost $64.64 and required 11.9 h runtime.Conclusions  GPT-5.5 demonstrated the ability to localize anatomical landmarks on lateral knee radiographs using a zero-shot, definition-only prompting strategy with modest localization error. Although performance is insufficient for full independent deployment, VLMs show promise as first-pass annotation tools that may reduce the manual labelling burden associated with orthopaedic pose-estimation data sets.Level of evidence  Level IV.
SN  - 2197-1153
ER  -