Maximizing the fidelity of a photovoltaic subretinal prosthesis for human patients
- 1Stanford University
- 2EPFL
Abstract
Objective. PRIMA subretinal implants provide prosthetic vision to patients blinded by age-related macular degeneration, with acuity closely matching the sampling limit of the pixel pitch: a single 100 μ m pixel per line of a letter corresponds to 20/420 acuity. Decreasing the pixel size in the same flat geometry is difficult due to the constrained electric field, especially considering a 40 μ m thick debris layer separating the implant from the target neurons. Here we optimize the electrode design to help overcome such limitations. Approach. An end-to-end modeling pipeline combines the retinal photovoltaic implant simulator based on the Xyce circuit simulator with an interface to COMSOL Multiphysics for electric field modelling. It was used to generate and characterize implants in an open-loop sampling-based optimization. Implant performance was evaluated with respect to voltage drop across bipolar cells (BC) (representing the stimulation strength), pattern contrast, and neural selectivity. Main results. The highest selectivity in stimulation of BCs was achieved with arrays having active electrodes on pillars and return electrodes connected in a mesh surrounding the photovoltaic pixels in the array. Such a design, even with pixels down to 20 μ m, provides stimulation strength exceeding, and contrast similar to that of flat 100 μ m PRIMA pixels. Significance. Using a novel 3D electrode design, the pitch of the photovoltaic array can be decreased to 20 μ m, while providing performance that exceeds the flat 100 μ m PRIMA pixels. In humans, 20 μ m resolution on the retina corresponds to a visual acuity of 20/80 – a five times improvement compared to the current clinical device.
Related
- Spatiotemporal multiplexing on subretinal prosthesis increases selectivity of the network-mediated stimulation
- Optimization of DsCPV-1 Infection Timing in Manduca sexta for Maximizing Viral Productivity in Mass Production
- Biomimetic scaffolds mimic human subretinal debris for preclinical testing of prosthetic vision
- Multimodal imaging reveals surface degradation of voice prosthesis implants resulting from colonisation by polymicrobial biofilms
- Limb-specific mediolateral ground reaction force impulses during cross-slope walking in unilateral lower-limb prosthesis users
BibTeX
@article{jensen2026maximizing,
title = {{Maximizing the fidelity of a photovoltaic subretinal prosthesis for human patients}},
author = {Nathan Jensen and Keith Ly and Anna Kochnev Goldstein and Quentin Devaud and Daniel Palanker},
journal = {Journal of Neural Engineering},
year = {2026},
month = jun,
doi = {10.1088/1741-2552/ae6d77},
url = {https://doi.org/10.1088/1741-2552/ae6d77},
note = {CC BY},
}
RIS
TY - JOUR
TI - Maximizing the fidelity of a photovoltaic subretinal prosthesis for human patients
AU - Nathan Jensen
AU - Keith Ly
AU - Anna Kochnev Goldstein
AU - Quentin Devaud
AU - Daniel Palanker
PY - 2026
DA - 2026/06/01
JO - Journal of Neural Engineering
DO - 10.1088/1741-2552/ae6d77
UR - https://doi.org/10.1088/1741-2552/ae6d77
AB - Objective. PRIMA subretinal implants provide prosthetic vision to patients blinded by age-related macular degeneration, with acuity closely matching the sampling limit of the pixel pitch: a single 100 μ m pixel per line of a letter corresponds to 20/420 acuity. Decreasing the pixel size in the same flat geometry is difficult due to the constrained electric field, especially considering a 40 μ m thick debris layer separating the implant from the target neurons. Here we optimize the electrode design to help overcome such limitations. Approach. An end-to-end modeling pipeline combines the retinal photovoltaic implant simulator based on the Xyce circuit simulator with an interface to COMSOL Multiphysics for electric field modelling. It was used to generate and characterize implants in an open-loop sampling-based optimization. Implant performance was evaluated with respect to voltage drop across bipolar cells (BC) (representing the stimulation strength), pattern contrast, and neural selectivity. Main results. The highest selectivity in stimulation of BCs was achieved with arrays having active electrodes on pillars and return electrodes connected in a mesh surrounding the photovoltaic pixels in the array. Such a design, even with pixels down to 20 μ m, provides stimulation strength exceeding, and contrast similar to that of flat 100 μ m PRIMA pixels. Significance. Using a novel 3D electrode design, the pitch of the photovoltaic array can be decreased to 20 μ m, while providing performance that exceeds the flat 100 μ m PRIMA pixels. In humans, 20 μ m resolution on the retina corresponds to a visual acuity of 20/80 – a five times improvement compared to the current clinical device.
SN - 1741-2552
SN - 1741-2560
ER -