Skip to content
DraconiticResearch
Search Sources API
197,768 studies31 sourcesUpdated 49 min ago
PreprintCC BYbioRxiv

Biomimetic scaffolds mimic human subretinal debris for preclinical testing of prosthetic vision

  1. 1Stanford University

Abstract

Photovoltaic subretinal prostheses replace the lost photoreceptors in patients blinded by atrophic age-related macular degeneration (AMD) and provide central vision by electrically stimulating the inner retinal neurons. Subretinal debris in geographic atrophy separate the inner nuclear layer from the implant by tens of micrometers, increasing the stimulation threshold and reducing the pattern contrast. Absence of this separating layer in animal models diminishes the accuracy of preclinical testing of the next-generation implants, especially with smaller pixels. We developed three-dimensional biomimetic scaffolds nanoprinted onto photovoltaic arrays to provide a precisely controlled separation between the implants and target neurons in animal models of retinal degeneration. Gap sizes of the scaffolds were adjusted to meet the following requirements: they should allow light penetration to the implant, provide unobstructed flow of electric current, but preclude migration of cells into their 3-D structure. Gaps of 3 m were found to be optimal as they restricted cellular migration and maintained the inner nuclear layer above both planar and pillar electrode arrays. Scaffolds did not measurably alter the photovoltaic response and accurately reproduced the distance dependence of stimulation threshold. Following implantation, the initially fluid-filled intra-scaffold space was progressively filled by cellular matter matching the density of the subretinal debris. This transition is expected to increase resistivity of the scaffold to that of tissue, which was evidenced by concurrently improved grating acuity. These results establish a model of the controlled separation between the implant and the target neurons reproducing the features of subretinal debris in geographic atrophy of human patients, thereby providing a platform for accurate preclinical evaluation of the subretinal implants.

Related

  1. Multichannel, biomimetic scaffolds improve functional connectivity following traumatic long-gap peripheral nerve injury.
    Jacob Koffler, Eleni Sinopoulou, Isac Lazarovits +6
    Nature communicationsPeer-reviewedCC BYFull textNeuroscienceEurope PMC
  2. Matrix Vesicle Nanostructures Guide Spatially Organized Bone-Like Mineralization in Biomimetic Collagen Scaffolds
    Lucas Fabricio Bahia Nogueira, Yuri Ferreira Da Silva, Maryanne Trafani de Melo +8
    ACS Biomaterials Science and EngineeringPeer-reviewedCC BY 4.0Full textSystems & synthetic biologyHAL
  3. Multi-Lab Testing of Early Preclinical Discoveries Identifies Promising Treatments
    P. Pellegrini, S. C. Rotter, M. Arroyo-Araujo +36
    bioRxivPreprintCC BYFull textGeneral biologybioRxiv
  4. Stimulation-stability and preclinical bench testing of a new auditory nerve interface.
    Taylor Stump, Stefan Strahl, Joseph Crew +9
    Bioelectronic medicinePeer-reviewedCC BY-NC-NDFull textNeuroscienceEurope PMC
  5. Collagen-producing eye cell atlas reveals distinct fibroblast fates in early injury vs. fibrotic subretinal disease
    Ema Ozaki, Said Aktas, Kelly Mulfaul +13
    Proceedings of the National Academy of Sciences of the United States of AmericaPeer-reviewedCC BY 4.0Full text2 citedSystems & synthetic biologyMedical imaging & radiologyHAL
BibTeX
@misc{bhuckory2026biomimetic,
  title = {{Biomimetic scaffolds mimic human subretinal debris for preclinical testing of prosthetic vision}},
  author = {M. B. Bhuckory and V. Mamchik and K. Ly and N. Jensen and V. Shautsova and Q. Devaud and A. J. W. Shin and D. Pham-Howard and R. Dalal and L. Galambos and T. Kamins and D. Palanker},
  howpublished = {bioRxiv},
  year = {2026},
  month = oct,
  doi = {10.64898/2026.10.06.756601},
  url = {https://www.biorxiv.org/content/10.64898/2026.10.06.756601v1},
  note = {CC BY},
}
RIS
TY  - UNPB
TI  - Biomimetic scaffolds mimic human subretinal debris for preclinical testing of prosthetic vision
AU  - M. B. Bhuckory
AU  - V. Mamchik
AU  - K. Ly
AU  - N. Jensen
AU  - V. Shautsova
AU  - Q. Devaud
AU  - A. J. W. Shin
AU  - D. Pham-Howard
AU  - R. Dalal
AU  - L. Galambos
AU  - T. Kamins
AU  - D. Palanker
PY  - 2026
DA  - 2026/10/06
PB  - bioRxiv
DO  - 10.64898/2026.10.06.756601
UR  - https://www.biorxiv.org/content/10.64898/2026.10.06.756601v1
AB  - Photovoltaic subretinal prostheses replace the lost photoreceptors in patients blinded by atrophic age-related macular degeneration (AMD) and provide central vision by electrically stimulating the inner retinal neurons. Subretinal debris in geographic atrophy separate the inner nuclear layer from the implant by tens of micrometers, increasing the stimulation threshold and reducing the pattern contrast. Absence of this separating layer in animal models diminishes the accuracy of preclinical testing of the next-generation implants, especially with smaller pixels. We developed three-dimensional biomimetic scaffolds nanoprinted onto photovoltaic arrays to provide a precisely controlled separation between the implants and target neurons in animal models of retinal degeneration. Gap sizes of the scaffolds were adjusted to meet the following requirements: they should allow light penetration to the implant, provide unobstructed flow of electric current, but preclude migration of cells into their 3-D structure. Gaps of 3 m were found to be optimal as they restricted cellular migration and maintained the inner nuclear layer above both planar and pillar electrode arrays. Scaffolds did not measurably alter the photovoltaic response and accurately reproduced the distance dependence of stimulation threshold. Following implantation, the initially fluid-filled intra-scaffold space was progressively filled by cellular matter matching the density of the subretinal debris. This transition is expected to increase resistivity of the scaffold to that of tissue, which was evidenced by concurrently improved grating acuity. These results establish a model of the controlled separation between the implant and the target neurons reproducing the features of subretinal debris in geographic atrophy of human patients, thereby providing a platform for accurate preclinical evaluation of the subretinal implants.
ER  -