Alternating-Luminophore Electrochemiluminescence Microscopy Reveals Developmental Stages of Brine Shrimp.
- 1Department of Chemistry, Purdue University, West Lafayette, Indiana 47907, United States.
Abstract
Brine shrimp (Artemia sp.) are model organisms used in ecotoxicity studies and other important biological testing. These mesoscale (l × w × h = 100s - 1000s μm) organisms mature rapidly and are ideal candidates for whole-organism imaging due to their ease of culture, definable anatomy, and well-documented development. We employ electrochemiluminescence (ECL) microscopy to examine both the chemical environment and morphology of these developing lower-level crustaceans on an electrified interface. We survey the tris-(2,2'-bipyridyl)-ruthenium-(II) ([Ru-(bpy)3]2+) and luminol luminophores, highlighting important trade-offs across developmental stages. In the luminol system, positive ECL emission occurs from the cyst (egg) despite no addition of coreactant, thus pointing toward the potential location of reactive oxygen species in the local chemical environment near the cyst. We find that the kinetic regime (lower potentials) of the [Ru-(bpy)3]2+ to be confined to the electrode surface and the Artemia. In contrast, in the mass-transfer-limited regime (higher potentials), shadow ECL dominates as Artemia acts as a blocking entity. Furthermore, we sum ECL micrographs and analyze the resulting composite images to evaluate trade-offs between temporal resolution and ECL intensity. Overall, this work establishes a foundation for mesoscale imaging of multicellular organisms and highlights the challenges and opportunities associated with ECL microscopy and luminophore choice.
Related
- Imaging the reactivity of carbon nitride nanosheets by photoinduced cathodic electrochemiluminescence microscopy
- Correlative super-resolution microscopy reveals preferential localization of quantum color center formation on carbon nanotubes
- Correlative Potential and Impedance Microscopy Reveals Particle-Level Degradation and Transport Heterogeneity in Solid-State Composite Cathodes
- Electrochemiluminescence Sensor for Uric Acid Detection Using Natural Enzyme‐Confined Nanozyme Cascade
- Temporally decoupled electrochemiluminescence breaks the sensitivity–portability tradeoff in water toxicity sensing
BibTeX
@article{layman2026alternatingluminophore,
title = {{Alternating-Luminophore Electrochemiluminescence Microscopy Reveals Developmental Stages of Brine Shrimp.}},
author = {Brady R Layman and Jeffrey E Dick},
journal = {Chemical \& biomedical imaging},
year = {2026},
month = jun,
doi = {10.1021/cbmi.6c00087},
url = {https://europepmc.org/article/MED/42953700},
note = {CC BY-NC-ND},
}
RIS
TY - JOUR
TI - Alternating-Luminophore Electrochemiluminescence Microscopy Reveals Developmental Stages of Brine Shrimp.
AU - Brady R Layman
AU - Jeffrey E Dick
PY - 2026
DA - 2026/06/30
JO - Chemical & biomedical imaging
DO - 10.1021/cbmi.6c00087
UR - https://europepmc.org/article/MED/42953700
AB - Brine shrimp (Artemia sp.) are model organisms used in ecotoxicity studies and other important biological testing. These mesoscale (l × w × h = 100s - 1000s μm) organisms mature rapidly and are ideal candidates for whole-organism imaging due to their ease of culture, definable anatomy, and well-documented development. We employ electrochemiluminescence (ECL) microscopy to examine both the chemical environment and morphology of these developing lower-level crustaceans on an electrified interface. We survey the tris-(2,2'-bipyridyl)-ruthenium-(II) ([Ru-(bpy)3]2+) and luminol luminophores, highlighting important trade-offs across developmental stages. In the luminol system, positive ECL emission occurs from the cyst (egg) despite no addition of coreactant, thus pointing toward the potential location of reactive oxygen species in the local chemical environment near the cyst. We find that the kinetic regime (lower potentials) of the [Ru-(bpy)3]2+ to be confined to the electrode surface and the Artemia. In contrast, in the mass-transfer-limited regime (higher potentials), shadow ECL dominates as Artemia acts as a blocking entity. Furthermore, we sum ECL micrographs and analyze the resulting composite images to evaluate trade-offs between temporal resolution and ECL intensity. Overall, this work establishes a foundation for mesoscale imaging of multicellular organisms and highlights the challenges and opportunities associated with ECL microscopy and luminophore choice.
SN - 2832-3637
ER -