Skip to content
DraconiticResearch
Search Sources API
276,906 studies31 sourcesUpdated 46 min ago
Peer-reviewedCC BY-NC-NDBMC anesthesiology

Modified nasopharyngeal airway device facilitates nasal fiberoptic intubation for trainee anesthesiologists: a randomized clinical study.

  1. 1Department of Anesthesiology, Faculty of Medicine Ramathibodi Hospital, Mahidol University, Bangkok, 10400, Thailand.
  2. 2Department of Anesthesiology, Faculty of Medicine Ramathibodi Hospital, Mahidol University, Bangkok, 10400, Thailand. [email protected].

Abstract

Background

Fiberoptic nasotracheal intubation is an essential skill for anesthesiologists. Trainee anesthesiologists often face challenges due to the complex anatomy of the nasopharynx and the risk of upper airway collapse after anesthesia administration, which can lead to confusion and difficulty in identifying the glottic opening. This study evaluated whether a modified nasopharyngeal airway (mNPA) device can assist less experienced operators in performing nasal fiberoptic intubation on anesthetized patients with non-difficult airway.Methods

This randomized controlled trial analyzed 54 patients undergoing elective surgery with nasal intubation. The patients were then assigned to either the mNPA group (n = 28) or the conventional nasal fiberoptic intubation (cNFI) group (n = 26). In the mNPA group, a modified airway guided the flexible fiberoptic bronchoscope to the glottis, and the device was subsequently removed to facilitate intubation. Trainee anesthesiologists performed all intubations. The primary outcome was intubation time. The secondary outcomes included first-attempt success rate and bleeding complications.Results

The mNPA group had a significantly faster vocal cord visualization time (11.49 vs. 47.56 s, P < 0.001) and a shorter intubation time (56.25 vs. 107.02 s, P < 0.001) than the cNFI group. The mNPA group had a significantly higher first-attempt success rate (96.43% vs. 73.08%, P value = 0.038) and a significantly lower incidence of blood staining in the periglottic area (3.57% vs. 26.92%, P value = 0.022) than the cNFI group.Conclusion

The mNPA significantly improved nasotracheal intubation time and success rates and reduced the number of attempts and bleeding complication rates for operators with limited experience in performing nasal fiberoptic intubation in non-difficult airway patients.Trial registration

Thai Clinical Trials Registry TCTR20230809006. Registered 9 August 2023.

Related

  1. One-lung Ventilation for Neonatal Pneumonectomy in a Hydropic Premature Infant: Fiberoptic-guided Left Mainstem Intubation
    Zeliha Bozkurt, Büşra G. Erol, Nezir Yılmaz
    Turkish Journal of Anaesthesiology and ReanimationPeer-reviewedCC BY 4.0Full textSurgery & anaesthesiaPMC
  2. airQ intubating laryngeal airway: An alternative to intubating laryngeal mask airway for fiberoptic guided intubation in neutral head position
    Aastha Gupta, Neerja Banerjee, Archana Khokar +3
    Journal of Dr. NTR University of Health SciencesPeer-reviewedCC BY-NC-SAFull textSurgery & anaesthesiaDOAJ
  3. Compound chamomile and lidocaine hydrochloride gel for postoperative sore throat after nasotracheal intubation: a randomized controlled trial
    Wei Luo, Linlin Jiang, Dan Zhang +5
    Scientific ReportsPeer-reviewedCC BY-NC-ND 4.0Full textSurgery & anaesthesiaCrossref
  4. Cervical spine motion during tracheal intubation with videolaryngoscopy versus Macintosh laryngoscopy in adults undergoing cervical spine surgery: a randomized controlled trial
    Hieu Trung Doan, Thang Toan Nguyen, Anh Thi Hong Nguyen +1
    Brazilian Journal of AnesthesiologyPeer-reviewedCC BY 4.0Full textSurgery & anaesthesiaPMC
  5. Comparison of Classic Laryngeal Mask Airway and Endotracheal Intubation for Airway Management During Short Urologic Procedures in the Prone Position: A Randomized Controlled Trial.
    Naeimeh Naeimi Bafghi, Maryam Shamsoddini Motlagh, Neda Naeimi Bafghi +1
    Anesthesiology research and practicePeer-reviewedCC BYFull textSurgery & anaesthesiaEurope PMC
BibTeX
@article{vijitpavan2026modified,
  title = {{Modified nasopharyngeal airway device facilitates nasal fiberoptic intubation for trainee anesthesiologists: a randomized clinical study.}},
  author = {Amorn Vijitpavan and Poonyanuch Charoenkoop and Waralak Raksong and Rachapha Kitphasert},
  journal = {BMC anesthesiology},
  year = {2026},
  month = aug,
  doi = {10.1186/s12871-026-04154-7},
  url = {https://europepmc.org/article/MED/43052804},
  note = {CC BY-NC-ND},
}
RIS
TY  - JOUR
TI  - Modified nasopharyngeal airway device facilitates nasal fiberoptic intubation for trainee anesthesiologists: a randomized clinical study.
AU  - Amorn Vijitpavan
AU  - Poonyanuch Charoenkoop
AU  - Waralak Raksong
AU  - Rachapha Kitphasert
PY  - 2026
DA  - 2026/08/08
JO  - BMC anesthesiology
DO  - 10.1186/s12871-026-04154-7
UR  - https://europepmc.org/article/MED/43052804
AB  - Background  Fiberoptic nasotracheal intubation is an essential skill for anesthesiologists. Trainee anesthesiologists often face challenges due to the complex anatomy of the nasopharynx and the risk of upper airway collapse after anesthesia administration, which can lead to confusion and difficulty in identifying the glottic opening. This study evaluated whether a modified nasopharyngeal airway (mNPA) device can assist less experienced operators in performing nasal fiberoptic intubation on anesthetized patients with non-difficult airway.Methods  This randomized controlled trial analyzed 54 patients undergoing elective surgery with nasal intubation. The patients were then assigned to either the mNPA group (n = 28) or the conventional nasal fiberoptic intubation (cNFI) group (n = 26). In the mNPA group, a modified airway guided the flexible fiberoptic bronchoscope to the glottis, and the device was subsequently removed to facilitate intubation. Trainee anesthesiologists performed all intubations. The primary outcome was intubation time. The secondary outcomes included first-attempt success rate and bleeding complications.Results  The mNPA group had a significantly faster vocal cord visualization time (11.49 vs. 47.56 s, P < 0.001) and a shorter intubation time (56.25 vs. 107.02 s, P < 0.001) than the cNFI group. The mNPA group had a significantly higher first-attempt success rate (96.43% vs. 73.08%, P value = 0.038) and a significantly lower incidence of blood staining in the periglottic area (3.57% vs. 26.92%, P value = 0.022) than the cNFI group.Conclusion  The mNPA significantly improved nasotracheal intubation time and success rates and reduced the number of attempts and bleeding complication rates for operators with limited experience in performing nasal fiberoptic intubation in non-difficult airway patients.Trial registration  Thai Clinical Trials Registry TCTR20230809006. Registered 9 August 2023.
SN  - 1471-2253
ER  -