Transradial Versus Transfemoral Access for Percutaneous Coronary Intervention: Procedural Efficiency, Radiation Exposure and In-Hospital Outcomes in a Real-World Single-Center Cohort
- 1Department of Cardiology, Faculty of Medicine, Kütahya Health Sciences University, Evliya Çelebi Campus, Tavşanlı Yolu 10. km, Kütahya 43100, Türkiye
Abstract
Background/Objectives: Transradial access (TRA) is the guideline-recommended default for coronary procedures, yet transfemoral access (TFA) remains common, and concerns persist that TRA prolongs procedures and increases radiation exposure. We compared procedural efficiency, radiation exposure and in-hospital outcomes between TRA and TFA in percutaneous coronary intervention (PCI). Methods: This single-center retrospective cohort study included consecutive patients who underwent PCI by five radial-experienced operators through a single access route. Procedure time and contrast volume (primary outcomes), and dose–area product (DAP) and air kerma (secondary outcomes) were compared using log-linear regression adjusted for pre-procedural covariates and by inverse probability of treatment weighting (IPTW). In-hospital major adverse cardiac and cerebrovascular events (MACCE) and major bleeding were exploratory outcomes. Results: Of 202 patients (mean age 61.9 ± 12.3 years; 24.3% women), 88 (43.6%) underwent TRA and 114 (56.4%) TFA; TFA was used in 71.3% of patients with ST-segment elevation myocardial infarction (STEMI). After adjustment, TRA was associated with 18% shorter procedure time (ratio of geometric means 0.82; 95% CI 0.71–0.95) and 16% less contrast (0.84; 0.73–0.95); IPTW and sensitivity analyses were directionally consistent. Air kerma (0.80; 0.64–1.01) and DAP (0.83; 0.67–1.03) were not significantly lower. In-hospital MACCE (5.7% vs. 6.1%; p = 0.891) and major bleeding (1.1% vs. 0.9%; p = 1.000) were infrequent. Conclusions: In this observational PCI cohort treated by radial-experienced operators, TRA was associated with shorter procedures and less contrast use than TFA. These associations, possibly reflecting access-site selection, do not establish causality; clinical events were too few to assess safety.
Related
- Procedural efficiency, diagnostic yield, and safety of a novel positioning grid combined with a non-coplanar puncture-angle guide for CT-guided percutaneous transthoracic lung biopsy: a retrospective contemporaneous-control study
- A novel distal radial artery compression device versus elastic bandage compression after coronary angiography or percutaneous coronary intervention via distal transradial access: a prospective randomized controlled trial
- Prognostic value of chronic total occlusion complexity scoring systems beyond procedural planning: a comparative analysis of five contemporary scores in patients undergoing chronic total occlusion percutaneous coronary intervention
- Epicardial Versus Septal Collateral Channels in Retrograde Chronic Total Occlusion Percutaneous Coronary Intervention: Procedural Safety and Long-Term Outcomes.
- Delayed Hemodynamic Collapse From Subclavian Artery Perforation Following Transradial Coronary Intervention, Requiring Rescue Endovascular Stenting
BibTeX
@article{kaya2026transradial,
title = {{Transradial Versus Transfemoral Access for Percutaneous Coronary Intervention: Procedural Efficiency, Radiation Exposure and In-Hospital Outcomes in a Real-World Single-Center Cohort}},
author = {Emrah Kaya and Fatih Kahraman and Gökhan Sönmez and Barış Küçük and Ömer Furtuna},
journal = {Journal of Clinical Medicine},
year = {2026},
month = nov,
doi = {10.3390/jcm15228799},
url = {https://www.mdpi.com/2077-0383/15/22/8799},
note = {CC BY 4.0},
}
RIS
TY - JOUR
TI - Transradial Versus Transfemoral Access for Percutaneous Coronary Intervention: Procedural Efficiency, Radiation Exposure and In-Hospital Outcomes in a Real-World Single-Center Cohort
AU - Emrah Kaya
AU - Fatih Kahraman
AU - Gökhan Sönmez
AU - Barış Küçük
AU - Ömer Furtuna
PY - 2026
DA - 2026/11/01
JO - Journal of Clinical Medicine
DO - 10.3390/jcm15228799
UR - https://www.mdpi.com/2077-0383/15/22/8799
AB - Background/Objectives: Transradial access (TRA) is the guideline-recommended default for coronary procedures, yet transfemoral access (TFA) remains common, and concerns persist that TRA prolongs procedures and increases radiation exposure. We compared procedural efficiency, radiation exposure and in-hospital outcomes between TRA and TFA in percutaneous coronary intervention (PCI). Methods: This single-center retrospective cohort study included consecutive patients who underwent PCI by five radial-experienced operators through a single access route. Procedure time and contrast volume (primary outcomes), and dose–area product (DAP) and air kerma (secondary outcomes) were compared using log-linear regression adjusted for pre-procedural covariates and by inverse probability of treatment weighting (IPTW). In-hospital major adverse cardiac and cerebrovascular events (MACCE) and major bleeding were exploratory outcomes. Results: Of 202 patients (mean age 61.9 ± 12.3 years; 24.3% women), 88 (43.6%) underwent TRA and 114 (56.4%) TFA; TFA was used in 71.3% of patients with ST-segment elevation myocardial infarction (STEMI). After adjustment, TRA was associated with 18% shorter procedure time (ratio of geometric means 0.82; 95% CI 0.71–0.95) and 16% less contrast (0.84; 0.73–0.95); IPTW and sensitivity analyses were directionally consistent. Air kerma (0.80; 0.64–1.01) and DAP (0.83; 0.67–1.03) were not significantly lower. In-hospital MACCE (5.7% vs. 6.1%; p = 0.891) and major bleeding (1.1% vs. 0.9%; p = 1.000) were infrequent. Conclusions: In this observational PCI cohort treated by radial-experienced operators, TRA was associated with shorter procedures and less contrast use than TFA. These associations, possibly reflecting access-site selection, do not establish causality; clinical events were too few to assess safety.
SN - 2077-0383
ER -