Whole-repetition quadriceps sEMG during flywheel squat and leg press: a randomized crossover study
4 affiliations
- 1Department of Physical Education and Sports Teaching, Faculty of Sport Sciences, Bursa Uludağ University, Bursa, Türkiye
- 2Department of Common Courses, Rectorate, Bursa Technical University, Bursa, Türkiye
- 3Institute of Human Movement Science, Sport and Health, Graz University, Graz, Austria
- 4School of Human Kinetics and Recreation, Memorial University of Newfoundland, St. John’s, NL, Canada
Abstract
Purpose: Flywheel squat and leg press differ simultaneously in resistance characteristics, body support, posture, movement-control demands, and loading strategy. This study compared the whole-repetition surface electromyographic (sEMG) amplitudes of the rectus femoris (RF), vastus lateralis (VL), and vastus medialis (VM) between the two exercise configurations.
Methods: Following two familiarization sessions, 18 resistance-trained men (age: 22.4 ± 3.6 years; body mass: 77.7 ± 11.2 kg; height: 181.1 ± 6.2 cm) completed both exercises in a randomized, counterbalanced crossover design, with 7 days between sessions. Each condition comprised three sets of six analyzed repetitions with 2-min recovery. Flywheel sets included two preparatory repetitions and were performed with individualized inertia and maximal concentric intent; leg press used participant-specific 6RM-based loading and a cadence prescribed from familiarization. Root mean square sEMG was normalized to maximum voluntary contraction and calculated across each complete repetition, combining concentric and eccentric phases. The primary outcome was the mean across 18 repetitions per condition. Muscle-specific linear mixed-effects models adjusted for sequence and period, with Benjamini–Hochberg correction across muscles.
Results: No significant between-exercise differences were detected after multiplicity adjustment. Flywheel-minus-leg-press differences were −9.90 percentage points for RF (95% CI [−20.81, 1.01], adjusted p = .192), 2.58 for VL (95% CI [−7.33, 12.49], adjusted p = .588), and 8.57 for VM (95% CI [−2.76, 19.89], adjusted p = .192). Point estimates favored the leg press for RF and the flywheel squat for VM, but all confidence intervals included zero. Set effects were detected for RF and VL, but absolute changes were approximately 0.5 percentage points, with no Exercise × Set interaction. The VM: VL ratio was inconclusive (ratio of ratios = 1.07, 95% CI [0.89, 1.29], p = .451).
Conclusion: The data did not establish a clear difference between flywheel squat and leg press in mean whole-repetition RF, VL, or VM sEMG amplitude. The confidence intervals, particularly for RF and VM, remained compatible with both no difference and potentially meaningful muscle-specific effects; equivalence was not tested.
Related
- Feasibility of Laryngeal Mask Airway insertion during continuous chest compressions in neonatal resuscitation: a randomized crossover simulation study
- Manual ventilation with and without a flow limiting device during induction of general anesthesia: a randomized crossover trial
- Hematological and biochemical responses to three doses of caffeine during the CrossFit® workout: a randomized, double-blind, crossover trial.
- Mechanical ventilation vs bag-valve ventilation during cardiopulmonary resuscitation: a randomized crossover noninferiority trial
- Effects of a High-Airflow Fan-Attached Garment on Thermoregulatory and Physiological Responses During Physical Activity in Hot Environments: A Randomized Crossover Trial
BibTeX
@article{topcu2026wholerepetition,
title = {{Whole-repetition quadriceps sEMG during flywheel squat and leg press: a randomized crossover study}},
author = {Hüseyin Topçu and Mert Arabacı and Coşkun Rodoplu and Josef Fischer and Duane C. Button and Andreas Konrad},
journal = {Frontiers in Physiology},
year = {2026},
month = nov,
doi = {10.3389/fphys.2026.1982568},
url = {https://doi.org/10.3389/fphys.2026.1982568},
note = {CC BY 4.0},
}
RIS
TY - JOUR
TI - Whole-repetition quadriceps sEMG during flywheel squat and leg press: a randomized crossover study
AU - Hüseyin Topçu
AU - Mert Arabacı
AU - Coşkun Rodoplu
AU - Josef Fischer
AU - Duane C. Button
AU - Andreas Konrad
PY - 2026
DA - 2026/11/03
JO - Frontiers in Physiology
DO - 10.3389/fphys.2026.1982568
UR - https://doi.org/10.3389/fphys.2026.1982568
AB - Purpose: Flywheel squat and leg press differ simultaneously in resistance characteristics, body support, posture, movement-control demands, and loading strategy. This study compared the whole-repetition surface electromyographic (sEMG) amplitudes of the rectus femoris (RF), vastus lateralis (VL), and vastus medialis (VM) between the two exercise configurations. Methods: Following two familiarization sessions, 18 resistance-trained men (age: 22.4 ± 3.6 years; body mass: 77.7 ± 11.2 kg; height: 181.1 ± 6.2 cm) completed both exercises in a randomized, counterbalanced crossover design, with 7 days between sessions. Each condition comprised three sets of six analyzed repetitions with 2-min recovery. Flywheel sets included two preparatory repetitions and were performed with individualized inertia and maximal concentric intent; leg press used participant-specific 6RM-based loading and a cadence prescribed from familiarization. Root mean square sEMG was normalized to maximum voluntary contraction and calculated across each complete repetition, combining concentric and eccentric phases. The primary outcome was the mean across 18 repetitions per condition. Muscle-specific linear mixed-effects models adjusted for sequence and period, with Benjamini–Hochberg correction across muscles. Results: No significant between-exercise differences were detected after multiplicity adjustment. Flywheel-minus-leg-press differences were −9.90 percentage points for RF (95% CI [−20.81, 1.01], adjusted p = .192), 2.58 for VL (95% CI [−7.33, 12.49], adjusted p = .588), and 8.57 for VM (95% CI [−2.76, 19.89], adjusted p = .192). Point estimates favored the leg press for RF and the flywheel squat for VM, but all confidence intervals included zero. Set effects were detected for RF and VL, but absolute changes were approximately 0.5 percentage points, with no Exercise × Set interaction. The VM: VL ratio was inconclusive (ratio of ratios = 1.07, 95% CI [0.89, 1.29], p = .451). Conclusion: The data did not establish a clear difference between flywheel squat and leg press in mean whole-repetition RF, VL, or VM sEMG amplitude. The confidence intervals, particularly for RF and VM, remained compatible with both no difference and potentially meaningful muscle-specific effects; equivalence was not tested.
SN - 1664-042X
ER -