Distinguishing evidence of absence from absence of evidence in claims of safety: A methodological study with application to diagnostic hysteroscopy in endometrial cancer
- 1Universidad del Desarrollo Facultad de Medicina
Abstract
Background: Claims that an intervention is safe often rest on a nonsignificant difference, confusing absence of evidence with evidence of absence; an integrated, reproducible procedure for auditing them is lacking. We developed and evaluated one, applying it to diagnostic hysteroscopy in endometrial cancer, which published syntheses describe as oncologically safe. Methods and findings: The framework's eight steps verify each number, test the direction of confounding, require time-to-event analysis, bound detectability and apply one information-adjusted boundary to claims of harm and of safety (verdicts: harm established, safety established, inconclusive). The rule was fixed before a retrospective test on minimally invasive radical hysterectomy for cervical cancer, later assessed in a randomized trial, and evaluated analytically and by simulation. We audited 18 comparative studies of hysteroscopy, 12 with peritoneal cytology (4,078 patients) and 5 with time-to-event recurrence estimates. With a true hazard ratio (HR) of 1.25 and the information available for hysteroscopy, inferring safety from nonsignificance gave false reassurance in 34% of analyses and the rule in 1%; with adequate information and no harm, the rule established safety in 80%. Pre-trial evidence on minimally invasive radical hysterectomy proved inconclusive, not safe. For hysteroscopy, controlling for disease extent revealed an association with positive cytology (odds ratio 2.86, 95% confidence interval [CI] 1.24-6.62) absent from crude comparisons; recurrence data (HR 1.17, Hartung-Knapp 95% CI 0.90-1.52) held 71% of the required information and were inconclusive at margins from 1.10 to 1.40; and harm through cytology would be undetectable in low-risk disease. Limitations include development on the case to which it is applied, a retrospective test of author-selected evidence, and reliance on published observational data. Conclusions: The framework distinguishes evidence of absence from absence of evidence in claims of safety and can be applied with a published confidence interval in minutes. It provides a reproducible, low-barrier procedure for clinicians, reviewers and guideline panels to audit such claims and apply proportionate precaution.
Related
- A Multi-Task ResNet-50 Framework for Simultaneous Classification and Triage of Endometrial Lesions Based on Hysteroscopy Images
- Chronic Retained Products of Conception Masked by Müllerian Duct Anomaly: The Diagnostic Value of Hysteroscopy
- Structured reporting of diagnostic hysteroscopy findings in women with reproductive disorders: an ESGE–ESHRE–IFFS international consensus†ǂ
- Electrophysiology in Distinguishing Functional Tremor from Organic Tremor: A Systematic Review and Meta‐Analysis of Diagnostic Accuracy
- Diagnostic value of targeted next-generation sequencing for distinguishing Aspergillus infection from colonization in non-neutropenic patients
BibTeX
@misc{alliendeferrada2026distinguishing,
title = {{Distinguishing evidence of absence from absence of evidence in claims of safety: A methodological study with application to diagnostic hysteroscopy in endometrial cancer}},
author = {R. Alliende-Ferrada and B. Mena and A. Ruz and R. Benavides and E. Larrain and I. Inostroza and P. Torres-Chomon},
howpublished = {medRxiv},
year = {2026},
month = nov,
doi = {10.64898/2026.11.20.26368573},
url = {https://www.medrxiv.org/content/10.64898/2026.11.20.26368573v1},
note = {CC BY},
}
RIS
TY - UNPB
TI - Distinguishing evidence of absence from absence of evidence in claims of safety: A methodological study with application to diagnostic hysteroscopy in endometrial cancer
AU - R. Alliende-Ferrada
AU - B. Mena
AU - A. Ruz
AU - R. Benavides
AU - E. Larrain
AU - I. Inostroza
AU - P. Torres-Chomon
PY - 2026
DA - 2026/11/20
PB - medRxiv
DO - 10.64898/2026.11.20.26368573
UR - https://www.medrxiv.org/content/10.64898/2026.11.20.26368573v1
AB - Background: Claims that an intervention is safe often rest on a nonsignificant difference, confusing absence of evidence with evidence of absence; an integrated, reproducible procedure for auditing them is lacking. We developed and evaluated one, applying it to diagnostic hysteroscopy in endometrial cancer, which published syntheses describe as oncologically safe. Methods and findings: The framework's eight steps verify each number, test the direction of confounding, require time-to-event analysis, bound detectability and apply one information-adjusted boundary to claims of harm and of safety (verdicts: harm established, safety established, inconclusive). The rule was fixed before a retrospective test on minimally invasive radical hysterectomy for cervical cancer, later assessed in a randomized trial, and evaluated analytically and by simulation. We audited 18 comparative studies of hysteroscopy, 12 with peritoneal cytology (4,078 patients) and 5 with time-to-event recurrence estimates. With a true hazard ratio (HR) of 1.25 and the information available for hysteroscopy, inferring safety from nonsignificance gave false reassurance in 34% of analyses and the rule in 1%; with adequate information and no harm, the rule established safety in 80%. Pre-trial evidence on minimally invasive radical hysterectomy proved inconclusive, not safe. For hysteroscopy, controlling for disease extent revealed an association with positive cytology (odds ratio 2.86, 95% confidence interval [CI] 1.24-6.62) absent from crude comparisons; recurrence data (HR 1.17, Hartung-Knapp 95% CI 0.90-1.52) held 71% of the required information and were inconclusive at margins from 1.10 to 1.40; and harm through cytology would be undetectable in low-risk disease. Limitations include development on the case to which it is applied, a retrospective test of author-selected evidence, and reliance on published observational data. Conclusions: The framework distinguishes evidence of absence from absence of evidence in claims of safety and can be applied with a published confidence interval in minutes. It provides a reproducible, low-barrier procedure for clinicians, reviewers and guideline panels to audit such claims and apply proportionate precaution.
ER -