Diagnostic accuracy of surgeon-performed point-of-care ultrasonography using Tokyo guidelines criteria for acute cholecystitis: a prospective diagnostic accuracy study.
5 affiliations
- 1Department of General Surgery, Hospital General Regional Vicente Guerrero, Instituto Mexicano del Seguro Social (IMSS), Avenida Adolfo Ruiz Cortines s/n Acapulco De Juárez, Col. Alta Progreso, Acapulco De Juárez, 39610, Guerrero, Mexico. [email protected].
- 2Faculty of Medicine, Benemérita Universidad Autónoma de Puebla, Puebla, Puebla, Mexico. [email protected].
- 3Department of General Surgery, Hospital General Regional Vicente Guerrero, Instituto Mexicano del Seguro Social (IMSS), Avenida Adolfo Ruiz Cortines s/n Acapulco De Juárez, Col. Alta Progreso, Acapulco De Juárez, 39610, Guerrero, Mexico.
- 4Hospital Privado Magallanes, Acapulco, Guerrero, Mexico.
- 5Faculty of Medicine, Benemérita Universidad Autónoma de Puebla, Puebla, Puebla, Mexico.
Abstract
Background
Acute calculous cholecystitis is a common surgical emergency. In health systems with delayed or limited access to radiology-performed ultrasonography, diagnostic delays may increase complications, length of stay, and resource utilization. Surgeon-performed point-of-care ultrasonography may expedite evaluation; however, its diagnostic accuracy when incorporated into structured diagnostic frameworks such as the Tokyo criteria remains uncertain.Methods
We conducted a prospective observational diagnostic accuracy study in the emergency department of a second-level referral hospital. Adult patients with clinical suspicion of acute cholecystitis were enrolled during recruitment shifts. All participants underwent standardized clinical evaluation, surgeon-performed point-of-care ultrasonography using a handheld device, and radiology-performed ultrasonography. The reference standard was pragmatic: histopathology for operated patients and structured clinical follow-up for up to 2 months for nonoperated patients. Diagnostic performance (sensitivity, specificity, likelihood ratios, predictive values, and post-test probability) was calculated for surgeon-performed ultrasonography alone, radiology-performed ultrasonography, and the Tokyo criteria using either imaging modality.Results
A total of 170 patients were included (mean age 42.8 years; 78.8% women). Surgeon-performed point-of-care ultrasonography considered positive with at least 1 sonographic finding demonstrated a sensitivity of 96.4% and specificity of 55.6%, with strong rule-out capability (negative likelihood ratio 0.06; negative post-test probability approximately 1%). Radiology-performed ultrasonography showed a sensitivity of 82.1% and specificity of 64.1%. When integrated into the Tokyo criteria, surgeon-performed ultrasonography yielded a sensitivity of 78.6% and specificity of 80.3%, comparable to Tokyo criteria using radiology-performed ultrasonography, with no statistically significant difference in paired classification.Conclusions
Surgeon-performed point-of-care ultrasonography demonstrated excellent sensitivity and rule-out performance. When incorporated into the Tokyo diagnostic criteria, its diagnostic performance was comparable to radiology-performed ultrasonography, supporting its use as a practical diagnostic alternative in emergency surgical settings with limited access to radiology services.
Related
- Comparison of lung ultrasonography and chest radiography in detecting neonatal respiratory distress as a composite clinical condition: a prospective cross-sectional diagnostic accuracy study at Muhimbili National Hospital
- Xanthogranulomatous Cholecystitis Presenting as Chronic Calculous Cholecystitis: A Diagnostic Challenge
- Current Role of Endoscopic Ultrasonography in the Early Detection of Pancreatic Cancer: Recognition of Indirect Imaging Findings and Diagnostic Strategy
- Diagnostic Performance of Ultrasonography and Mammography in Detecting Local Recurrence after Breast-conserving Surgery: A Systematic Review and Exploratory Diagnostic Meta-analysis
- Development and internal validation of an objective diagnostic model based on gastric filling ultrasonography for gastric stump carcinoma: a TRIPOD-compliant retrospective study.
BibTeX
@article{servin2026diagnostic,
title = {{Diagnostic accuracy of surgeon-performed point-of-care ultrasonography using Tokyo guidelines criteria for acute cholecystitis: a prospective diagnostic accuracy study.}},
author = {Francisco Xavier González Servín and Luis Rodrigo Barrera Guerra and Ethel Jenny García Cruz and Luis Manuel Uribe Galán and Alberto García Rodríguez and Gerardo Alvarado Romero and Edgar Balbuena Herrera},
journal = {Langenbeck's archives of surgery},
year = {2026},
month = sep,
doi = {10.1007/s00423-026-04154-8},
url = {https://europepmc.org/article/MED/43077161},
note = {CC BY-NC-ND},
}
RIS
TY - JOUR
TI - Diagnostic accuracy of surgeon-performed point-of-care ultrasonography using Tokyo guidelines criteria for acute cholecystitis: a prospective diagnostic accuracy study.
AU - Francisco Xavier González Servín
AU - Luis Rodrigo Barrera Guerra
AU - Ethel Jenny García Cruz
AU - Luis Manuel Uribe Galán
AU - Alberto García Rodríguez
AU - Gerardo Alvarado Romero
AU - Edgar Balbuena Herrera
PY - 2026
DA - 2026/09/01
JO - Langenbeck's archives of surgery
DO - 10.1007/s00423-026-04154-8
UR - https://europepmc.org/article/MED/43077161
AB - Background Acute calculous cholecystitis is a common surgical emergency. In health systems with delayed or limited access to radiology-performed ultrasonography, diagnostic delays may increase complications, length of stay, and resource utilization. Surgeon-performed point-of-care ultrasonography may expedite evaluation; however, its diagnostic accuracy when incorporated into structured diagnostic frameworks such as the Tokyo criteria remains uncertain.Methods We conducted a prospective observational diagnostic accuracy study in the emergency department of a second-level referral hospital. Adult patients with clinical suspicion of acute cholecystitis were enrolled during recruitment shifts. All participants underwent standardized clinical evaluation, surgeon-performed point-of-care ultrasonography using a handheld device, and radiology-performed ultrasonography. The reference standard was pragmatic: histopathology for operated patients and structured clinical follow-up for up to 2 months for nonoperated patients. Diagnostic performance (sensitivity, specificity, likelihood ratios, predictive values, and post-test probability) was calculated for surgeon-performed ultrasonography alone, radiology-performed ultrasonography, and the Tokyo criteria using either imaging modality.Results A total of 170 patients were included (mean age 42.8 years; 78.8% women). Surgeon-performed point-of-care ultrasonography considered positive with at least 1 sonographic finding demonstrated a sensitivity of 96.4% and specificity of 55.6%, with strong rule-out capability (negative likelihood ratio 0.06; negative post-test probability approximately 1%). Radiology-performed ultrasonography showed a sensitivity of 82.1% and specificity of 64.1%. When integrated into the Tokyo criteria, surgeon-performed ultrasonography yielded a sensitivity of 78.6% and specificity of 80.3%, comparable to Tokyo criteria using radiology-performed ultrasonography, with no statistically significant difference in paired classification.Conclusions Surgeon-performed point-of-care ultrasonography demonstrated excellent sensitivity and rule-out performance. When incorporated into the Tokyo diagnostic criteria, its diagnostic performance was comparable to radiology-performed ultrasonography, supporting its use as a practical diagnostic alternative in emergency surgical settings with limited access to radiology services.
SN - 1435-2443
SN - 1435-2451
ER -