Skip to content
DraconiticResearch
Search Sources API
203,203 studies31 sourcesUpdated 8 min ago
PreprintCC BY 4.0arXiv

Effective Sub-Quantum Readout for Non-Monochromatic Axion Signals in High-Q Haloscopes

Abstract

The search for wave-like dark matter using microwave cavity haloscopes is constrained by the Standard Quantum Limit, which dictates that phase-preserving linear amplification results in a minimum of one quantum of total system noise for a narrow-band signal. We demonstrate that this limit is effectively halved for a non-monochromatic axion signal coupled to a high-Q cavity. By operating a Josephson Parametric Amplifier such that the cavity resonance is centered exactly at the half-pump frequency, the axion signal symmetrically populates both the signal and idler bands. Through quadrature analysis of the homodyne readout, we show that the incoherent sum of these mirrored spectral components doubles the measured signal power while the vacuum noise remains constant. This operation yields an effective noise limit of 0.5 quanta per frequency bin, translating to an overall effective limit of 1/√2 quanta after optimal matched filtering.

Related

  1. Photon-Counting Readout via Electro-Optic Microwave-to-Optical Transduction for Axion Haloscopes
    Jing Wu, Raphael Cervantes, Doga Murat Kurkcuoglu +2
    arXivPreprintCC BY 4.0Full textHigh-energy & particle physicsQuantum physics & quantum informationarXiv
  2. Realization of a Primary Irradiance Scale for Solar irradiance Measurements based on a Predictable Quantum Efficient Detector and a Quasi-Monochromatic Portable Tunable Source.
    Geiland Porrovecchio, Julian Gröbner, Marek Smid
    Optics ExpressPeer-reviewedLicence not statedOptics & photonicsCrossref
  3. Design and Modeling of the Charge Readout of a SiMOS Quantum Dot with a Single Electron Transistor and CryoCMOS
    Adam Quinn, Troy England, Andrew Li +1
    arXivPreprintCC BY 4.0Full textApplied physics & instrumentationCondensed matterarXiv
  4. Near-Quantum-Limited Readout for the Princeton Axion Search using a sub-GHz Kinetic Inductance Traveling Wave Parametric Amplifier
    Joe Wiedemann, Roman Kolevatov, Jianyang Fu +7
    arXivPreprintarXiv licenceFull textInstrumentation & methodsHigh-energy & particle physicsarXiv
  5. Near-exact Upper Confidence Limits for Axion Haloscopes
    Andrea Gallo Rosso, Jan Conrad
    arXivPreprintCC BY 4.0Full textInstrumentation & methodsComputational physicsarXiv
BibTeX
@misc{jeong2026effective,
  title = {{Effective Sub-Quantum Readout for Non-Monochromatic Axion Signals in High-$Q$ Haloscopes}},
  author = {Junu Jeong and Max Silva-Feaver},
  howpublished = {arXiv},
  year = {2026},
  month = sep,
  doi = {10.48550/arxiv.2609.02828},
  eprint = {2609.02828},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2609.02828},
  note = {CC BY 4.0},
}
RIS
TY  - UNPB
TI  - Effective Sub-Quantum Readout for Non-Monochromatic Axion Signals in High-Q Haloscopes
AU  - Junu Jeong
AU  - Max Silva-Feaver
PY  - 2026
DA  - 2026/09/02
PB  - arXiv
DO  - 10.48550/arxiv.2609.02828
UR  - https://arxiv.org/abs/2609.02828
AB  - The search for wave-like dark matter using microwave cavity haloscopes is constrained by the Standard Quantum Limit, which dictates that phase-preserving linear amplification results in a minimum of one quantum of total system noise for a narrow-band signal. We demonstrate that this limit is effectively halved for a non-monochromatic axion signal coupled to a high-Q cavity. By operating a Josephson Parametric Amplifier such that the cavity resonance is centered exactly at the half-pump frequency, the axion signal symmetrically populates both the signal and idler bands. Through quadrature analysis of the homodyne readout, we show that the incoherent sum of these mirrored spectral components doubles the measured signal power while the vacuum noise remains constant. This operation yields an effective noise limit of 0.5 quanta per frequency bin, translating to an overall effective limit of 1/√2 quanta after optimal matched filtering.
ER  -