Modulation of [99mTc]Tc-iPSMA preparation conditions reduces radiochemical species heterogeneity and supports a single-vial cold-kit formulation
Abstract
Introduction: Technetium-99m labeling of hydrazinonicotinamide (HYNIC)-conjugated vectors requires transfer ligands and co-ligands that may generate multiple radiochemical species with slightly different physicochemical and biological properties. This study aimed to optimize the radiolabeling of the HYNIC-conjugated prostate-specific membrane antigen ligand iPSMA to reduce chromatographic heterogeneity while maintaining high radiochemical purity (RCP), and to translate the selected conditions into a single-vial cold-kit formulation. Methods: Twenty radiolabeling conditions were evaluated through 3 replicates each by independently varying the co-ligand, transfer ligand, buffer, reducing agent, antioxidant, reaction time, and reaction temperature. Products were characterized by radio-HPLC and radio-TLC. The optimized conditions were subsequently applied to freeze-dried single-vial formulations containing one of five bulking agents. The effects of bulking-agent content, technetium-99 m activity, heating time, and pertechnetate eluate age were also investigated. Results: The reference protocol yielded an RCP of 90.31 ± 0.83%, with the predominant radiolabeled species accounting for 76.97 ± 2.53% of the radiocomplexes. Among the investigated parameters, reaction-medium composition, particularly the buffer used, had the greatest influence on the chromatographic distribution of radiolabeled species. Using sodium acetate 0.2 M at pH 7 with EDDA and tricine increased RCP to 95.15 ± 0.29% and the proportion of the predominant radiolabeled species to 96.21 ± 0.23%. Reduced/hydrolyzed technetium remained below the radio-TLC detection limit. Mannitol provided the best cold-kit performance and was selected at 40 mg per vial. Under the present formulation conditions, satisfactory kit performance was obtained with ≤1.5 GBq of freshly eluted pertechnetate (<30 min), with 0.92 ± 0.11% residual pertechnetate, 91.47 ± 2.66% major radiolabeled species, and a RCP of 95.69 ± 1.28%. Conclusion: Radio-HPLC-guided optimization markedly reduced radiochemical heterogeneity of [99mTc]Tc-iPSMA while maintaining high RCP. The selected conditions could be translated into an all-in-one single-vial proof-of-concept formulation, although further analytical, pharmaceutical and biological development is required before clinical implementation.
Related
- An LFP-based characterization of population-level heterogeneity during motor preparation & execution
- Silicon-mediated modulation of physiological performance, nutrient status and yield formation in winter wheat under field conditions
- From CAF heterogeneity to immune modulation and therapeutic targeting: a subtype-based framework
- Effects of a multistrain probiotic formulation on immune response and microbiome modulation following influenza vaccination in adults: a randomised, triple-blind, placebo-controlled trial
- Heterogeneity of Brain Dynamics in Genetic and Psychiatric Conditions
BibTeX
@article{chillard2026modulation,
title = {{Modulation of [99mTc]Tc-iPSMA preparation conditions reduces radiochemical species heterogeneity and supports a single-vial cold-kit formulation}},
author = {Jeanne Chillard and Lina Stamboul and Jade Torchio and Léa Rubira and Cyril Fersing},
journal = {Frontiers in Nuclear Medicine},
year = {2026},
month = nov,
doi = {10.3389/fnume.2026.1980206},
url = {https://hal.science/hal-05874060v1},
note = {CC BY 4.0},
}
RIS
TY - JOUR
TI - Modulation of [99mTc]Tc-iPSMA preparation conditions reduces radiochemical species heterogeneity and supports a single-vial cold-kit formulation
AU - Jeanne Chillard
AU - Lina Stamboul
AU - Jade Torchio
AU - Léa Rubira
AU - Cyril Fersing
PY - 2026
DA - 2026/11/20
JO - Frontiers in Nuclear Medicine
DO - 10.3389/fnume.2026.1980206
UR - https://hal.science/hal-05874060v1
AB - Introduction: Technetium-99m labeling of hydrazinonicotinamide (HYNIC)-conjugated vectors requires transfer ligands and co-ligands that may generate multiple radiochemical species with slightly different physicochemical and biological properties. This study aimed to optimize the radiolabeling of the HYNIC-conjugated prostate-specific membrane antigen ligand iPSMA to reduce chromatographic heterogeneity while maintaining high radiochemical purity (RCP), and to translate the selected conditions into a single-vial cold-kit formulation. Methods: Twenty radiolabeling conditions were evaluated through 3 replicates each by independently varying the co-ligand, transfer ligand, buffer, reducing agent, antioxidant, reaction time, and reaction temperature. Products were characterized by radio-HPLC and radio-TLC. The optimized conditions were subsequently applied to freeze-dried single-vial formulations containing one of five bulking agents. The effects of bulking-agent content, technetium-99 m activity, heating time, and pertechnetate eluate age were also investigated. Results: The reference protocol yielded an RCP of 90.31 ± 0.83%, with the predominant radiolabeled species accounting for 76.97 ± 2.53% of the radiocomplexes. Among the investigated parameters, reaction-medium composition, particularly the buffer used, had the greatest influence on the chromatographic distribution of radiolabeled species. Using sodium acetate 0.2 M at pH 7 with EDDA and tricine increased RCP to 95.15 ± 0.29% and the proportion of the predominant radiolabeled species to 96.21 ± 0.23%. Reduced/hydrolyzed technetium remained below the radio-TLC detection limit. Mannitol provided the best cold-kit performance and was selected at 40 mg per vial. Under the present formulation conditions, satisfactory kit performance was obtained with ≤1.5 GBq of freshly eluted pertechnetate (<30 min), with 0.92 ± 0.11% residual pertechnetate, 91.47 ± 2.66% major radiolabeled species, and a RCP of 95.69 ± 1.28%. Conclusion: Radio-HPLC-guided optimization markedly reduced radiochemical heterogeneity of [99mTc]Tc-iPSMA while maintaining high RCP. The selected conditions could be translated into an all-in-one single-vial proof-of-concept formulation, although further analytical, pharmaceutical and biological development is required before clinical implementation.
SN - 2673-8880
ER -