A Highly Tunable (Ti,Zr)Nx-Based MIM Plasmonic Sensor for Multidomain Biological, Chemical, and Physical Sensing
Abstract
Metal-Insulator-Metal (MIM) plasmonic refractive index (RI) sensors have attracted considerable attention for label-free, real-time analyte detection; however, their reliance on noble metals such as gold and silver imposes fundamental constraints on tunability, thermal stability, and CMOS process compatibility. In this work, we propose a novel MIM plasmonic RI sensor based on a square ring resonator with embedded circular nanorods, employing the ternary nitride (Ti,Zr)Nx as the plasmonic material, marking its first application in a MIM sensing platform. Compared to binary nitrides and other alternative plasmonic materials reported in the literature, (Ti,Zr)Nx offers broader compositional tunability and greater flexibility in tailoring the optical response while remaining fully CMOS-compatible. The sensor is validated across a comprehensive range of biosensing and physicochemical analyte scenarios, including glucose monitoring for diabetes assessment, hemoglobin-based anemia classification across four severity levels, simultaneous discrimination of five major blood constituents, and cancer cell identification across six tissue types. For physical and chemical sensing, the structure achieves an air pressure sensitivity of 6.158 nm/MPa with negligible thermal cross-sensitivity, and a CO2 detection sensitivity of 330.12 pm/ppm via polyhexamethylene biguanide (PHMB) functionalization, which is the highest reported among comparable structures in the literature. The proposed sensor achieves a maximum RI sensitivity of 2146.496 nm/RIU with a detection limit of 4.669 × 10−7 RIU, outperforming previously reported CMOS-compatible plasmonic RI sensors.
Related
- Dual physical origins of polarization-independent scattering in plasmonic nanoparticle dimers
- From Chemical Complexity to Tunable Magnetic Ordering in Highly Disordered High-Entropy Spinel Oxides
- Toward Nanoscale Chemical Clarity: THz-Pulsed Atom Probe Tomography for Hydrated Biological Materials
- UV Fluorescence Sensing of Medical-Chemical-and- Biological Analytes by an AlGaN/Si-on-Sapphire Optoelectronic Chip
- An Exploration of Physical and Chemical Representation in Coarse-Grained, Machine-Learned Protein Models
BibTeX
@misc{kabir2026highly,
title = {{A Highly Tunable (Ti,Zr)N$_x$-Based MIM Plasmonic Sensor for Multidomain Biological, Chemical, and Physical Sensing}},
author = {Mohammad Abrar Kabir and Aosaf Jarif Siddiquee and Abdullah Taharat and A. K. M. Rakib and Rakibul Hasan Sagor},
howpublished = {arXiv},
year = {2026},
month = nov,
doi = {10.48550/arxiv.2611.30614},
eprint = {2611.30614},
archivePrefix = {arXiv},
url = {https://arxiv.org/abs/2611.30614},
}
RIS
TY - UNPB
TI - A Highly Tunable (Ti,Zr)N_x-Based MIM Plasmonic Sensor for Multidomain Biological, Chemical, and Physical Sensing
AU - Mohammad Abrar Kabir
AU - Aosaf Jarif Siddiquee
AU - Abdullah Taharat
AU - A. K. M. Rakib
AU - Rakibul Hasan Sagor
PY - 2026
DA - 2026/11/23
PB - arXiv
DO - 10.48550/arxiv.2611.30614
UR - https://arxiv.org/abs/2611.30614
AB - Metal-Insulator-Metal (MIM) plasmonic refractive index (RI) sensors have attracted considerable attention for label-free, real-time analyte detection; however, their reliance on noble metals such as gold and silver imposes fundamental constraints on tunability, thermal stability, and CMOS process compatibility. In this work, we propose a novel MIM plasmonic RI sensor based on a square ring resonator with embedded circular nanorods, employing the ternary nitride (Ti,Zr)N_x as the plasmonic material, marking its first application in a MIM sensing platform. Compared to binary nitrides and other alternative plasmonic materials reported in the literature, (Ti,Zr)N_x offers broader compositional tunability and greater flexibility in tailoring the optical response while remaining fully CMOS-compatible. The sensor is validated across a comprehensive range of biosensing and physicochemical analyte scenarios, including glucose monitoring for diabetes assessment, hemoglobin-based anemia classification across four severity levels, simultaneous discrimination of five major blood constituents, and cancer cell identification across six tissue types. For physical and chemical sensing, the structure achieves an air pressure sensitivity of 6.158 nm/MPa with negligible thermal cross-sensitivity, and a CO_2 detection sensitivity of 330.12 pm/ppm via polyhexamethylene biguanide (PHMB) functionalization, which is the highest reported among comparable structures in the literature. The proposed sensor achieves a maximum RI sensitivity of 2146.496 nm/RIU with a detection limit of 4.669 × 10^−7 RIU, outperforming previously reported CMOS-compatible plasmonic RI sensors.
ER -