Skip to content
DraconiticResearch
Search Sources API
189,280 studies31 sourcesUpdated 41 min ago
Peer-reviewedCC BY 4.0Journal of visualized experiments : JoVE

Patient-Specific Electric Field Simulation in Spinal Metastasis Electrochemotherapy

Abstract

Electrochemotherapy (ECT) combines the administration of cytotoxic agents with high-voltage electric pulses that transiently permeabilize tumor cell membranes and enhance intracellular drug uptake. This minimally invasive, nonthermal technique is particularly suitable for tumors located near critical structures, where surgery, radiotherapy, or percutaneous thermal ablation may be limited. In the spine, ECT can provide pain relief, neural decompression, and local tumor control while preserving neural structures. However, its implementation remains challenging due to complex vertebral anatomy, limited understanding of electric field distribution, the absence of dedicated planning tools, and the risk of neural injury. This protocol describes a reproducible workflow for patient-specific electric field simulation in spinal ECT. Multimodal imaging combining CT and MRI enables reconstruction of tumoral, vertebral, neural, and soft-tissue anatomy using semi-automatic and manual segmentations performed within the open-source 3D Slicer platform. Tissue conductivities are assigned according to the IT’IS database, and linear finite-element simulations (constant conductivity) are performed with AI4DEEP, a dedicated 3D Slicer module, to compute 3D electric field maps across multiple isodose thresholds. Follow-up contrast-enhanced MRI is used for validation through Dice similarity coefficients comparing simulated isoelectric field volumes with post-ECT necrotic tumoral areas. Qualitative comparison of simulated electric field maps, follow-up MRI, and clinical outcomes was performed by expert interventional radiologists to evaluate the ability of the software to predict undertreated and overtreated regions. Nine ECT procedures were processed to assess the workflow. The highest concordance between simulated electric field and post-ECT necrosis was observed in the 160–200 V/cm range in this specific clinical and numerical setting. The workflow also identified regions of insufficient or excessive treatment, consistent with clinical and imaging follow-up. The described workflow lays the groundwork for reproducible ECT planning, supporting optimized electrode placement and parameter adjustment to improve safety and efficacy in complex spinal ECT procedures.

Related

  1. A Differentiable, GPU-Accelerated Finite-Element Formulation in JAX for Large-Deformation Shells with Contact: Application to Patient-Specific Aortic Valve Simulation
    Mohsen Nakhaei, Alison M. Pouch, Matthew A. Jolley +1
    arXivPreprintCC BY 4.0Full textBioinformatics & computational biologyComputational physicsarXiv
  2. A scalable Zebrafish Platform for genetic validation and functional discovery of stage-specific breast cancer metastasis regulators
    Federica Ruscitto, Chiara Priami, Niccolò Roda +9
    Communications BiologyPeer-reviewedCC BY-NC-ND 4.0Full textCell biologyCrossref
  3. Advancing Electrochemotherapy in Melanoma and Non-Melanoma Skin Cancer: From Clinical Practice to Emerging Frontiers.
    Ramona Marrapodi, Arianna Presaghi, Emilia Migliano +1
    International journal of molecular sciencesPeer-reviewedCC BYFull textSystems & synthetic biologyEurope PMC
  4. A Physics-Informed Neural Network Surrogate for Patient-Specific Hepatic Arterial Hemodynamics in Yttrium-90 Radioembolization: Network Architecture, Boundary-Condition Enforcement, and Data Efficiency
    E. Taatizadeh, N. K. Panneer Selvam, E. Roncali
    bioRxivPreprintAll rights reservedFull textSystems & synthetic biologybioRxiv
  5. Human knee osteoarthritis patient-specific cartilage-on-a-chip model captures donor differences to stressors and treatments
    L. Banh, K. Perera, B. R. Lobo +9
    bioRxivPreprintAll rights reservedFull textSystems & synthetic biologybioRxiv
BibTeX
@article{beunon2026patientspecific,
  title = {{Patient-Specific Electric Field Simulation in Spinal Metastasis Electrochemotherapy}},
  author = {Paul Beunon and Baptiste Bonnet and Lambros Tselikas and Paul Janvier and Genti Xhepa and Olivier Sutter and Baudouin Denis de Senneville and Luc Lafitte and Olivier Seror and Lluis Mir and Frederic Deschamps and Clair Poignard},
  journal = {Journal of visualized experiments : JoVE},
  year = {2026},
  month = jul,
  doi = {10.3791/71239},
  url = {https://hal.science/hal-05805860v1},
  note = {CC BY 4.0},
}
RIS
TY  - JOUR
TI  - Patient-Specific Electric Field Simulation in Spinal Metastasis Electrochemotherapy
AU  - Paul Beunon
AU  - Baptiste Bonnet
AU  - Lambros Tselikas
AU  - Paul Janvier
AU  - Genti Xhepa
AU  - Olivier Sutter
AU  - Baudouin Denis de Senneville
AU  - Luc Lafitte
AU  - Olivier Seror
AU  - Lluis Mir
AU  - Frederic Deschamps
AU  - Clair Poignard
PY  - 2026
DA  - 2026/07/31
JO  - Journal of visualized experiments : JoVE
DO  - 10.3791/71239
UR  - https://hal.science/hal-05805860v1
AB  - Electrochemotherapy (ECT) combines the administration of cytotoxic agents with high-voltage electric pulses that transiently permeabilize tumor cell membranes and enhance intracellular drug uptake. This minimally invasive, nonthermal technique is particularly suitable for tumors located near critical structures, where surgery, radiotherapy, or percutaneous thermal ablation may be limited. In the spine, ECT can provide pain relief, neural decompression, and local tumor control while preserving neural structures. However, its implementation remains challenging due to complex vertebral anatomy, limited understanding of electric field distribution, the absence of dedicated planning tools, and the risk of neural injury. This protocol describes a reproducible workflow for patient-specific electric field simulation in spinal ECT. Multimodal imaging combining CT and MRI enables reconstruction of tumoral, vertebral, neural, and soft-tissue anatomy using semi-automatic and manual segmentations performed within the open-source 3D Slicer platform. Tissue conductivities are assigned according to the IT’IS database, and linear finite-element simulations (constant conductivity) are performed with AI4DEEP, a dedicated 3D Slicer module, to compute 3D electric field maps across multiple isodose thresholds. Follow-up contrast-enhanced MRI is used for validation through Dice similarity coefficients comparing simulated isoelectric field volumes with post-ECT necrotic tumoral areas. Qualitative comparison of simulated electric field maps, follow-up MRI, and clinical outcomes was performed by expert interventional radiologists to evaluate the ability of the software to predict undertreated and overtreated regions. Nine ECT procedures were processed to assess the workflow. The highest concordance between simulated electric field and post-ECT necrosis was observed in the 160–200 V/cm range in this specific clinical and numerical setting. The workflow also identified regions of insufficient or excessive treatment, consistent with clinical and imaging follow-up. The described workflow lays the groundwork for reproducible ECT planning, supporting optimized electrode placement and parameter adjustment to improve safety and efficacy in complex spinal ECT procedures.
SN  - 1940-087X
SN  - 1940-087X
ER  -