Comparison of 2D and 3D fast non-local means in pediatric abdominal low-dose computed tomographic image

  1. 1Department of Health Science, General Graduate School of Gachon University
  2. 2Department of Biomedical Engineering, Eulji University
  3. 3Department of Radiological Science, Gachon University

Abstract

Fast non-local means (FNLM) is a post-processing technique that suppresses noise while preserving edges. FNLM can be implemented in two-dimensional (2D) and three-dimensional (3D) forms, yet the effect of smoothing factor selection on performance in pediatric low-dose computed tomography (CT) remains unclear. This study applied 2D and 3D FNLM to 30 pediatric abdominal CT cases with simulated low-dose noise using smoothing factors from 0.001 to 0.060. Image quality was evaluated using the coefficient of variation (COV), peak signal-to-noise ratio (PSNR), and structural similarity index measure (SSIM). In both algorithms, COV decreased markedly as the smoothing factor increased, particularly from 0.001 to 0.016, whereas PSNR and SSIM showed relatively limited variation. SSIM reached the maximum value at 0.016, followed by a gradual decrease. Linear mixed-effects models demonstrated significant effects of the smoothing factor on all metrics. Wilcoxon signed-rank test indicated significantly lower COV and higher SSIM with 3D FNLM while PSNR showed no significant difference. 3D FNLM provided significant improvements in noise uniformity and structural preservation with modest effects. In contrast, 2D FNLM remains a practical option when computational efficiency takes priority. Overall, a smoothing factor around 0.016 offers a favorable balance between noise reduction and structural fidelity.

Related

  1. Comparative Analysis of Bilateral-Based Noise Reduction Algorithms in Low-Dose Pediatric Computed Tomographic Images.
    Minji Park, Hajin Kim, Sang Woong Park +2
    Diagnostics (Basel, Switzerland)Peer-reviewedCC BYFull textGeneral medicineEurope PMC
  2. Computed Tomographic Features Associated with Pulmonary Melioidosis versus Pulmonary Tuberculosis in Diabetic Patients: A Retrospective Comparative Cohort Study.
    Nitin Gupta, Chiranjay Mukhopadhyay, Tirlangi Praveen Kumar +7
    The American journal of tropical medicine and hygienePeer-reviewedCC BYFull textEpidemiology & public healthEurope PMC
  3. Multimodal Postmortem Investigation of Fatal Thoracic Metallic Projectile Trauma in a Jindo Dog: Radiographic, Computed Tomographic, Necropsy, and Histopathological Findings.
    Ah-Young Kim, Jongho Kim, Hansung Joo +3
    Animals : an open access journal from MDPIPeer-reviewedCC BYFull textMedical imaging & radiologyEurope PMC
  4. Automated Calculation of the Pediatric Emergency Care Applied Research Network (PECARN) Intra-Abdominal Injury Rule from Unstructured Emergency Department Notes Using a Large Language Model
    Leisha Devisetti, Belinda Chen, Newton Addo +5
    Journal of the American College of Emergency Physicians openPeer-reviewedCC BY-NC-NDFull textGeneral medicineEurope PMC
  5. Assessment of predictive efficacy for prognosis of pediatric severe Mycoplasma pneumoniae pneumonia: a comprehensive study based on high-resolution computed tomography imaging and platelet parameters
    Xiaoli Zhang, Wenzhuo Liu, Xiaohua Song +4
    Translational pediatricsPeer-reviewedCC BY-NC-NDFull textGeneral medicineEurope PMC
BibTeX
@article{park2026comparison,
  title = {{Comparison of 2D and 3D fast non-local means in pediatric abdominal low-dose computed tomographic image}},
  author = {Minji Park and Hajin Kim and Hyun-Woo Jeong and Youngjin Lee},
  journal = {Scientific Reports},
  year = {2026},
  month = jul,
  doi = {10.1038/s41598-026-62872-x},
  url = {https://doi.org/10.1038/s41598-026-62872-x},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - Comparison of 2D and 3D fast non-local means in pediatric abdominal low-dose computed tomographic image
AU  - Minji Park
AU  - Hajin Kim
AU  - Hyun-Woo Jeong
AU  - Youngjin Lee
PY  - 2026
DA  - 2026/07/01
JO  - Scientific Reports
DO  - 10.1038/s41598-026-62872-x
UR  - https://doi.org/10.1038/s41598-026-62872-x
AB  - Fast non-local means (FNLM) is a post-processing technique that suppresses noise while preserving edges. FNLM can be implemented in two-dimensional (2D) and three-dimensional (3D) forms, yet the effect of smoothing factor selection on performance in pediatric low-dose computed tomography (CT) remains unclear. This study applied 2D and 3D FNLM to 30 pediatric abdominal CT cases with simulated low-dose noise using smoothing factors from 0.001 to 0.060. Image quality was evaluated using the coefficient of variation (COV), peak signal-to-noise ratio (PSNR), and structural similarity index measure (SSIM). In both algorithms, COV decreased markedly as the smoothing factor increased, particularly from 0.001 to 0.016, whereas PSNR and SSIM showed relatively limited variation. SSIM reached the maximum value at 0.016, followed by a gradual decrease. Linear mixed-effects models demonstrated significant effects of the smoothing factor on all metrics. Wilcoxon signed-rank test indicated significantly lower COV and higher SSIM with 3D FNLM while PSNR showed no significant difference. 3D FNLM provided significant improvements in noise uniformity and structural preservation with modest effects. In contrast, 2D FNLM remains a practical option when computational efficiency takes priority. Overall, a smoothing factor around 0.016 offers a favorable balance between noise reduction and structural fidelity.
SN  - 2045-2322
ER  -