Skip to content
DraconiticResearch
Search Sources API
186,625 studies31 sourcesUpdated 48 min ago
Peer-reviewedCC BYScientific Reports

Gradient chamber for measuring the exhalation rate of radon and thoron from surfaces

  1. 1Faculty of Physics, Sofia University “St. Kliment Ohridski”

Abstract

A novel instrument (gradient chamber) and method for measuring the exhalation rates of radon (²²²Rn) and thoron (²²⁰Rn) from surfaces (e.g., soil, rocks, building materials) have been developed and tested. Determining radon and thoron exhalation rates is essential both for protecting human health from radon/thoron exposure and for providing valuable data relevant to climate change research. The chamber is cylindrical with open bases: the upper base is covered with a porous material that blocks atmospheric turbulence while remaining permeable to radon and thoron, and the lower base is placed in direct contact with the test surface. Within the chamber, radon and thoron activity concentrations form a diffusion profile, measured by detectors for alpha particles, installed at different heights inside the chamber walls. Each detector comprises a Kodak Pathe LR-115/II alpha track detector covered by activated carbon fabric (ACC-5092-10), which efficiently adsorbs radon and thoron. The detectors are compact (≈ 1 cm) and locally sensitive, enabling high-resolution profiling of radon and thoron distributions. Exhalation rates are determined from the diffusion gradient using Fick’s law. Results from theoretical modeling and pilot field experiments confirm the high sensitivity of this method, sufficient to quantify even low environmental radon exhalation rates from the earth’s surface.

Related

  1. Pacemaker Dependency in Patients Undergoing Implantation of Dual-chamber Devices After Alcohol Septum Ablation: A Retrospective Analysis
    Sophia Schulze Lammers, Dennis Lawin, Annika Hoyer +2
    CJC openPeer-reviewedCC BYFull textCardiovascular medicineEurope PMC
  2. Single-chamber retrievable leadless pacemaker in adult congenital heart disease: A single-center experience
    Giovanni Domenico Ciriello, Diego Colonna, Anna Correra +3
    Heart rhythm O2Peer-reviewedCC BY-NC-NDFull textCardiovascular medicineEurope PMC
  3. Automatic transesophageal echocardiographic evaluation of patients with mitral valve prolapse: comparison with patients without structural cardiac chamber remodeling (an exploratory study)
    Marcelo Luiz Campos Vieira, Ana C. T. Rodrigues, Edgar Daminello +17
    Journal of thoracic diseasePeer-reviewedCC BY-NC-NDFull textGeneral medicineEurope PMC
  4. Pulmonary Hypertension Increases Left Ventricular Chamber Stiffness Through Ventricular Interdependence and Is Attenuated by Pulmonary-Targeted SERCA2a Gene Therapy
    Jernie Rideb, Olympia Bikou, Kenji Watanabe +4
    American journal of physiology. Heart and circulatory physiologyPeer-reviewedCC BYFull textCardiovascular medicinePMC
  5. Heart failure and atrial fibrillation prediction from non-gated chest CT scans using AI-based cardiac chamber volumetry: an AI-CVD study within the multi-ethnic study of atherosclerosis (MESA)
    Seyed Reza Mirjalili, Kyle Atlas, Anthony P. Reeves +29
    American journal of preventive cardiologyPeer-reviewedCC BY-NC-NDFull textGeneral medicineEurope PMC
BibTeX
@article{pressyanov2026gradient,
  title = {{Gradient chamber for measuring the exhalation rate of radon and thoron from surfaces}},
  author = {Dobromir S. Pressyanov},
  journal = {Scientific Reports},
  year = {2026},
  month = jun,
  doi = {10.1038/s41598-026-55953-4},
  url = {https://doi.org/10.1038/s41598-026-55953-4},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - Gradient chamber for measuring the exhalation rate of radon and thoron from surfaces
AU  - Dobromir S. Pressyanov
PY  - 2026
DA  - 2026/06/01
JO  - Scientific Reports
DO  - 10.1038/s41598-026-55953-4
UR  - https://doi.org/10.1038/s41598-026-55953-4
AB  - A novel instrument (gradient chamber) and method for measuring the exhalation rates of radon (²²²Rn) and thoron (²²⁰Rn) from surfaces (e.g., soil, rocks, building materials) have been developed and tested. Determining radon and thoron exhalation rates is essential both for protecting human health from radon/thoron exposure and for providing valuable data relevant to climate change research. The chamber is cylindrical with open bases: the upper base is covered with a porous material that blocks atmospheric turbulence while remaining permeable to radon and thoron, and the lower base is placed in direct contact with the test surface. Within the chamber, radon and thoron activity concentrations form a diffusion profile, measured by detectors for alpha particles, installed at different heights inside the chamber walls. Each detector comprises a Kodak Pathe LR-115/II alpha track detector covered by activated carbon fabric (ACC-5092-10), which efficiently adsorbs radon and thoron. The detectors are compact (≈ 1 cm) and locally sensitive, enabling high-resolution profiling of radon and thoron distributions. Exhalation rates are determined from the diffusion gradient using Fick’s law. Results from theoretical modeling and pilot field experiments confirm the high sensitivity of this method, sufficient to quantify even low environmental radon exhalation rates from the earth’s surface.
SN  - 2045-2322
ER  -