Reverse Transcription Loop-Mediated Isothermal Amplification Combined with Lateral Flow Assay (RT-LAMP-LFA) for Rapid Detection of the 2026 Bundibugyo Virus (BDBV) Outbreak Strain
- 1Nagasaki Daigaku
Abstract
Making accurate diagnosis is a critical first step in patient management and control for emerging and re-emerging disease outbreaks. Bundibugyo virus (BDBV) is a filovirus that causes Ebola disease, and the 2026 outbreak highlights the need for rapid diagnostic approaches that can be deployed in settings with limited laboratory infrastructure. Here, we developed a reverse transcription loop-mediated isothermal amplification-lateral flow assay (RT-LAMP-LFA) for rapid detection of the 2026 BDBV outbreak strain. LAMP primers were designed based on the genome sequence of the 2026 outbreak strain, and the conservation of the primer binding sites among all available 2026 outbreak genomes was confirmed in silico. LAMP primers were evaluated for analytical specificity and sensitivity using in vitro-transcribed RNA (ivtRNA) from BDBV and other filoviruses, as well as RNA derived from arboviruses and mammalian cells. Amplification products were detected using a Chromatography-Printed Array Strip (C-PAS) lateral flow platform. The newly designed primers specifically detected the presence of BDBV RNA without nonspecific amplification of the other viral or cellular RNA samples tested. Consistent amplification was observed down to 103 copies per reaction. In addition, BDBV viral RNA was successfully amplified, and the amplification products were detected using C-PAS, with the total workflow being completed within 25 min. These findings demonstrate the analytical specificity and sensitivity of the developed RT-LAMP-LFA assay and its compatibility with rapid visual lateral flow detection, supporting its potential application as a point-of-care approach for BDBV detection.
Related
- Development of Loop-Mediated Isothermal Amplification Assays for Rapid and Sensitive Detection of Three Viruses Infecting Areca catechu L.
- Diagnostic utility of colourimetric readout loop-mediated isothermal amplification assay for rapid detection of Babesia gibsoni at the clinical point-of-care (POC)
- Genome-Informed Loop-Mediated Isothermal Amplification (LAMP) Assays for Detection and Differentiation of Ralstonia pseudosolanacearum Phylotypes I and III
- Development of loop-mediated isothermal amplification (LAMP) combined with a lateral flow dipstick DNA biosensor for detection of α thalassemia 1 [Southeast Asia (SEA), --SEA deletion]
- Novel Target for Pathogenic Leptospira Detection via Colorimetric Loop-Mediated Isothermal Amplification (LAMP): Development, Validation, and Comparative Analysis.
BibTeX
@misc{sato2026reverse,
title = {{Reverse Transcription Loop-Mediated Isothermal Amplification Combined with Lateral Flow Assay (RT-LAMP-LFA) for Rapid Detection of the 2026 Bundibugyo Virus (BDBV) Outbreak Strain}},
author = {L. S. Sato and M. Ihara and A. Hidano and Y. Takamatsu},
howpublished = {bioRxiv},
year = {2026},
month = nov,
doi = {10.64898/2026.11.09.765523},
url = {https://www.biorxiv.org/content/10.64898/2026.11.09.765523v1},
note = {CC BY},
}
RIS
TY - UNPB
TI - Reverse Transcription Loop-Mediated Isothermal Amplification Combined with Lateral Flow Assay (RT-LAMP-LFA) for Rapid Detection of the 2026 Bundibugyo Virus (BDBV) Outbreak Strain
AU - L. S. Sato
AU - M. Ihara
AU - A. Hidano
AU - Y. Takamatsu
PY - 2026
DA - 2026/11/09
PB - bioRxiv
DO - 10.64898/2026.11.09.765523
UR - https://www.biorxiv.org/content/10.64898/2026.11.09.765523v1
AB - Making accurate diagnosis is a critical first step in patient management and control for emerging and re-emerging disease outbreaks. Bundibugyo virus (BDBV) is a filovirus that causes Ebola disease, and the 2026 outbreak highlights the need for rapid diagnostic approaches that can be deployed in settings with limited laboratory infrastructure. Here, we developed a reverse transcription loop-mediated isothermal amplification-lateral flow assay (RT-LAMP-LFA) for rapid detection of the 2026 BDBV outbreak strain. LAMP primers were designed based on the genome sequence of the 2026 outbreak strain, and the conservation of the primer binding sites among all available 2026 outbreak genomes was confirmed in silico. LAMP primers were evaluated for analytical specificity and sensitivity using in vitro-transcribed RNA (ivtRNA) from BDBV and other filoviruses, as well as RNA derived from arboviruses and mammalian cells. Amplification products were detected using a Chromatography-Printed Array Strip (C-PAS) lateral flow platform. The newly designed primers specifically detected the presence of BDBV RNA without nonspecific amplification of the other viral or cellular RNA samples tested. Consistent amplification was observed down to 103 copies per reaction. In addition, BDBV viral RNA was successfully amplified, and the amplification products were detected using C-PAS, with the total workflow being completed within 25 min. These findings demonstrate the analytical specificity and sensitivity of the developed RT-LAMP-LFA assay and its compatibility with rapid visual lateral flow detection, supporting its potential application as a point-of-care approach for BDBV detection.
ER -