Efficacy and Safety of a Single Session of Micro‐Focused Ultrasound for Mid‐To‐Lower Facial Rejuvenation: A Retrospective Multimodal Assessment Study Using Clinical Evaluation, High‐Frequency Ultrasound, and VISIA Skin Analysis
- 1Department of Dermatology and Venereology People's Hospital of Xinjiang Uygur Autonomous Region; Xinjiang Clinical Research Center for Dermatologic Diseases; Xinjiang Key Laboratory of Dermatology Research Urumqi China
Abstract
Background: Micro‐Focused Ultrasound (MFU) is widely used for noninvasive facial rejuvenation. However, its effects on the middle and lower face have not been fully evaluated using multimodal assessment methods.
Aims: This study aimed to evaluate the efficacy and safety of a single MFU treatment for tightening and lifting of the middle and lower face by combining clinical evaluation with imaging‐based assessments.
Methods: Thirty female patients who underwent a single MFU treatment session were retrospectively included. Treatment was performed using both linear transducers (M3.0/M4.5) and large focal‐zone transducers (D3.0/D4.5). Clinical outcomes were evaluated using the Global Aesthetic Improvement Scale (GAIS), Facial Relaxation Scale (FRS), and Wrinkle Severity Rating Scale (WSRS) at baseline and at 1 and 3 months after treatment. Dermal thickness and echogenicity were assessed using high‐frequency ultrasound, and skin parameters were analyzed with the VISIA system. Pain scores and adverse events were also recorded.
Results: GAIS and FRS scores improved significantly at both follow‐up visits compared with baseline (p < 0.001). Nasolabial fold severity was significantly reduced at 1 month (p < 0.0167), with no further significant change observed at 3 months. High‐frequency ultrasound showed significant increases in dermal thickness and echogenicity after treatment (p < 0.001). VISIA analysis demonstrated significant improvements in wrinkles, texture, pores, and brown spots (p < 0.0167), whereas spots, redness, and UV pigmentation showed no significant changes. Pain was mild in 70% of patients. All adverse events were mild and transient.
Conclusions: A single MFU treatment can improve mid‐to‐lower facial laxity and overall facial appearance. Given the study limitations, this conclusion should be considered preliminary and exploratory in nature.
Related
- Longitudinal Multimodal Imaging Assessment of Tissue Changes Following Poly-L-Lactic Acid Treatment for Midfacial Rejuvenation: An Exploratory Pilot Study.
- AI-Assisted Sequential Graf Assessment of Infant Hip Ultrasound: A Retrospective Single-Centre Evaluation in a Referral Cohort.
- Microfocused ultrasound for facial and neck rejuvenation : A pilot prospective observational study on efficacy and safety in patients with skin laxity
- Evaluation and performance of the β-hCG discriminatory zone and targeted ultrasound findings for early pregnancy diagnosis in a high-risk population: a retrospective cohort study at a US safety-net hospital.
- Development of a nomogram for preoperative prediction of malignant risk in thyroid follicular tumors based on multimodal ultrasound and clinical features: A retrospective observational study
BibTeX
@article{qu2026efficacy,
title = {{Efficacy and Safety of a Single Session of Micro‐Focused Ultrasound for Mid‐To‐Lower Facial Rejuvenation: A Retrospective Multimodal Assessment Study Using Clinical Evaluation, High‐Frequency Ultrasound, and VISIA Skin Analysis}},
author = {Yuanyuan Qu and Fang Xiang and Jiawen Ma and Halina Hairola and Yuan Ding and Xiaojing Kang},
journal = {Journal of Cosmetic Dermatology},
year = {2026},
month = nov,
doi = {10.1111/jocd.71262},
url = {https://doi.org/10.1111/jocd.71262},
note = {CC BY 4.0},
}
RIS
TY - JOUR
TI - Efficacy and Safety of a Single Session of Micro‐Focused Ultrasound for Mid‐To‐Lower Facial Rejuvenation: A Retrospective Multimodal Assessment Study Using Clinical Evaluation, High‐Frequency Ultrasound, and VISIA Skin Analysis
AU - Yuanyuan Qu
AU - Fang Xiang
AU - Jiawen Ma
AU - Halina Hairola
AU - Yuan Ding
AU - Xiaojing Kang
PY - 2026
DA - 2026/11/13
JO - Journal of Cosmetic Dermatology
DO - 10.1111/jocd.71262
UR - https://doi.org/10.1111/jocd.71262
AB - Background: Micro‐Focused Ultrasound (MFU) is widely used for noninvasive facial rejuvenation. However, its effects on the middle and lower face have not been fully evaluated using multimodal assessment methods. Aims: This study aimed to evaluate the efficacy and safety of a single MFU treatment for tightening and lifting of the middle and lower face by combining clinical evaluation with imaging‐based assessments. Methods: Thirty female patients who underwent a single MFU treatment session were retrospectively included. Treatment was performed using both linear transducers (M3.0/M4.5) and large focal‐zone transducers (D3.0/D4.5). Clinical outcomes were evaluated using the Global Aesthetic Improvement Scale (GAIS), Facial Relaxation Scale (FRS), and Wrinkle Severity Rating Scale (WSRS) at baseline and at 1 and 3 months after treatment. Dermal thickness and echogenicity were assessed using high‐frequency ultrasound, and skin parameters were analyzed with the VISIA system. Pain scores and adverse events were also recorded. Results: GAIS and FRS scores improved significantly at both follow‐up visits compared with baseline (p < 0.001). Nasolabial fold severity was significantly reduced at 1 month (p < 0.0167), with no further significant change observed at 3 months. High‐frequency ultrasound showed significant increases in dermal thickness and echogenicity after treatment (p < 0.001). VISIA analysis demonstrated significant improvements in wrinkles, texture, pores, and brown spots (p < 0.0167), whereas spots, redness, and UV pigmentation showed no significant changes. Pain was mild in 70% of patients. All adverse events were mild and transient. Conclusions: A single MFU treatment can improve mid‐to‐lower facial laxity and overall facial appearance. Given the study limitations, this conclusion should be considered preliminary and exploratory in nature.