Skip to content
DraconiticResearch
Search Sources API
189,273 studies31 sourcesUpdated 59 min ago
PreprintarXiv licencearXiv

Through-thickness coupling of diffusion and viscoelastic relaxation in the transient bending of bilayer microcantilevers

Abstract

Static-mode microcantilever sensors detect chemical analytes through the bending of a bilayer beam whose polymer coating swells upon absorption. The transient bending is usually modeled as if the coating absorbed analyte uniformly, which is adequate for thin coatings but breaks down as the coating thickens and a moving diffusion front couples to depth-dependent viscoelastic relaxation. We resolve this coupling with a purpose-built finite-element solver requiring only one linear solve per time step, and show that the through-thickness structure controls the transient response in ways uniform-uptake models cannot capture. Verified against a published analytical solution, the solver reproduces the full transition from a pronounced curvature overshoot (up to nearly twice the steady-state value) when diffusion is fast relative to relaxation to a monotonic rise when it is slow. In the intermediate-thickness regime the analytical solution cannot reach, the thickness maximizing the steady-state signal and the thickness preserving the transient overshoot are governed by different physics, one geometric and one dynamic, so one coating cannot be optimized for both. The overshoot further survives realistic surface mass-transfer resistance, justifying the idealized surface boundary condition used throughout.

Related

  1. Geometry-Controlled Relaxation Spectra in Viscoelastic Fluids
    Niloyendu Roy, Rupayan Saha, Debankur Das +2
    arXivPreprintarXiv licenceFull textCondensed matterarXiv
  2. Diffusion stabilises time-periodic solutions in conservation laws coupled to a relaxation oscillator
    Julien Barre, Nils Berglund, Hiroshi Horii
    HALPreprintCC BY 4.0Full textAnalysis & PDEsDynamical systemsHALarXiv
  3. Non-steady diffusion and adsorption of organic micropollutants in ion-exchange membranes: effect of the membrane thickness
    Malgorzata Roman, Pawel Roman, Rhea Verbeke +9
    iSciencePeer-reviewedCC BY-NC-NDFull text17 citedCondensed matterHAL
  4. Universal link between structural relaxation and self-diffusion in simple supercooled liquids
    Mingyu Zhu, Xinyu Chang, Licun Fu +2
    arXivPreprintCC BY-NC-ND 4.0Full textCondensed matterarXiv
  5. Scaling law for the diffusion coefficient in vibration-driven crater relaxation
    Hayato Narita, Hiroaki Katsuragi
    arXivPreprintarXiv licenceFull textPlanetary science & exoplanetsCondensed matterarXiv
BibTeX
@misc{zhou2026throughthickness,
  title = {{Through-thickness coupling of diffusion and viscoelastic relaxation in the transient bending of bilayer microcantilevers}},
  author = {YingCheng Zhou and Kosuke Minami and Genki Yoshikawa},
  howpublished = {arXiv},
  year = {2026},
  month = sep,
  doi = {10.48550/arxiv.2609.09760},
  eprint = {2609.09760},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2609.09760},
}
RIS
TY  - UNPB
TI  - Through-thickness coupling of diffusion and viscoelastic relaxation in the transient bending of bilayer microcantilevers
AU  - YingCheng Zhou
AU  - Kosuke Minami
AU  - Genki Yoshikawa
PY  - 2026
DA  - 2026/09/09
PB  - arXiv
DO  - 10.48550/arxiv.2609.09760
UR  - https://arxiv.org/abs/2609.09760
AB  - Static-mode microcantilever sensors detect chemical analytes through the bending of a bilayer beam whose polymer coating swells upon absorption. The transient bending is usually modeled as if the coating absorbed analyte uniformly, which is adequate for thin coatings but breaks down as the coating thickens and a moving diffusion front couples to depth-dependent viscoelastic relaxation. We resolve this coupling with a purpose-built finite-element solver requiring only one linear solve per time step, and show that the through-thickness structure controls the transient response in ways uniform-uptake models cannot capture. Verified against a published analytical solution, the solver reproduces the full transition from a pronounced curvature overshoot (up to nearly twice the steady-state value) when diffusion is fast relative to relaxation to a monotonic rise when it is slow. In the intermediate-thickness regime the analytical solution cannot reach, the thickness maximizing the steady-state signal and the thickness preserving the transient overshoot are governed by different physics, one geometric and one dynamic, so one coating cannot be optimized for both. The overshoot further survives realistic surface mass-transfer resistance, justifying the idealized surface boundary condition used throughout.
ER  -