Preliminary Dose Constraints for Testing Intensity Modulated Proton Therapy in Anal Cancer Trials.

  1. 1Tata Memorial Centre, HBNI University, Mumbai, India.
  2. 2Advanced Centre for Treatment, Research and Education in Cancer, Tata Memorial Centre, HBNI University Mumbai, Mumbai, India.

Abstract

The target volume for radiotherapy of anal cancer is complex, with the added challenge of it being surrounded by several critical organs at risk (OARs). In this study, we review the dosimetric advantage that can be achieved with intensity modulated proton therapy (IMPT) over intensity modulated radiotherapy (IMRT) and derive the dose constraints for OARs. Ten consecutive patients of anal cancer treated using rotational IMRT (Rapid Arc; Varian Medical Systems, Palo Alto, USA) in 2023 were reviewed. The contours of the target volumes and OARs (bowel, bladder, marrow, bilateral femoral heads, and external genitalia) were reviewed on Eclipse (v16.1) treatment planning system for adherence to contouring guidelines. The clinical plans were re-evaluated for OAR doses and target volume coverage.The scans with structure sets were exported to RayStation treatment planning system (v12A) for intensity modulated proton therapy (IMPT) planning. The dose for IMPT planning was prescribed to the CTV with 5 mm robustness, keeping dose prescription similar to the clinical IMRT plan (45-50 Gy to pelvis and 55-60 Gy simultaneous boost to any gross disease and gross nodes). The 4 beam class solution was identified as best for IMPT planning. The IMPT plan objective was set 10% to 20% below the lower threshold of RTOG 05-29 and UK guidelines, followed by principles of ALARA for OARs without compromising target coverage. The dose-volume parameters, conformity index (CI) and homogeneity index (HI) were compared for IMRT versus IMPT using student's t-test. Target volume coverage was well achieved with both IMRT and IMPT. However, V100% of GTVp and GTVn and V95%, V98%, V99%, V100% of CTVPelvis and CTVTumourBoost were significantly better with IMPT. HI and CI of target volumes were also significantly improved with IMPT. There was a significant decrease in volume of OARs receiving doses <40 Gy. Volumes receiving higher doses (40-50 Gy) were very small and not significantly affected with use of IMPT. IMPT offers improved target coverage with reduction in low-intermediate dose spill to OARs. Based on these results, dose constraints for IMPT planning have been generated for future clinical trial validation.

Related

  1. Impact of anatomical changes on simulated proton arc therapy and intensity‐modulated proton therapy for lung cancer
    Wenguang Chen, Feng Yang, Fanrui Zeng +8
    Journal of Applied Clinical Medical PhysicsPeer-reviewedCC BY 4.0Full textApplied physics & instrumentationPMC
  2. In Silico Dosimetric Comparison of Intensity-Modulated Photon Versus Proton Therapy for Pelvic and Para-Aortic Nodal Recurrence of Prostate Cancer Following Prior Irradiation
    James A. Knight, Hao Chen, Anh Tran +9
    CancersPeer-reviewedCC BY 4.0Applied physics & instrumentationCrossref
  3. Nonlinear pluggable optics: Digital signal processing-free Intensity Modulated Direct Detection links using analog photonic Next Generation Reservoir Computing
    Nicholas Cox, Joseph Murray, Ross Schermer +6
    Optics ExpressPeer-reviewedLicence not statedOptics & photonicsCrossref
  4. Operando Charge Carrier Dynamics by Intensity-Modulated Photoluminescence: From Perovskite Thin Films to Solar Cells
    Constantin Bach, Dong Won Kim, Yitian Du +2
    arXivPreprintCC BY 4.0Full textApplied physics & instrumentationCondensed matterarXiv
  5. Dosimetric Comparison of Intensity-Modulated Radiotherapy and Four-Field Three-Dimensional Conformal Radiotherapy in the Management of Prostate Cancer: A Retrospective Dual-Centre Analysis
    Alaa AbdAllah, wafaa mohamed, Amani Saber +1
    Minia Journal of Medical ResearchPeer-reviewedCC BYFull textApplied physics & instrumentationDOAJ
BibTeX
@article{krishnatry2026preliminary,
  title = {{Preliminary Dose Constraints for Testing Intensity Modulated Proton Therapy in Anal Cancer Trials.}},
  author = {Rahul Krishnatry and Aditi Jain and Rohidas Punde and Shakthivel Mani and Shivakumar Gudi and Reena Engineer},
  journal = {International journal of particle therapy},
  year = {2026},
  month = oct,
  doi = {10.1016/j.ijpt.2026.101971},
  url = {https://europepmc.org/article/MED/42997743},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - Preliminary Dose Constraints for Testing Intensity Modulated Proton Therapy in Anal Cancer Trials.
AU  - Rahul Krishnatry
AU  - Aditi Jain
AU  - Rohidas Punde
AU  - Shakthivel Mani
AU  - Shivakumar Gudi
AU  - Reena Engineer
PY  - 2026
DA  - 2026/10/18
JO  - International journal of particle therapy
DO  - 10.1016/j.ijpt.2026.101971
UR  - https://europepmc.org/article/MED/42997743
AB  - The target volume for radiotherapy of anal cancer is complex, with the added challenge of it being surrounded by several critical organs at risk (OARs). In this study, we review the dosimetric advantage that can be achieved with intensity modulated proton therapy (IMPT) over intensity modulated radiotherapy (IMRT) and derive the dose constraints for OARs. Ten consecutive patients of anal cancer treated using rotational IMRT (Rapid Arc; Varian Medical Systems, Palo Alto, USA) in 2023 were reviewed. The contours of the target volumes and OARs (bowel, bladder, marrow, bilateral femoral heads, and external genitalia) were reviewed on Eclipse (v16.1) treatment planning system for adherence to contouring guidelines. The clinical plans were re-evaluated for OAR doses and target volume coverage.The scans with structure sets were exported to RayStation treatment planning system (v12A) for intensity modulated proton therapy (IMPT) planning. The dose for IMPT planning was prescribed to the CTV with 5 mm robustness, keeping dose prescription similar to the clinical IMRT plan (45-50 Gy to pelvis and 55-60 Gy simultaneous boost to any gross disease and gross nodes). The 4 beam class solution was identified as best for IMPT planning. The IMPT plan objective was set 10% to 20% below the lower threshold of RTOG 05-29 and UK guidelines, followed by principles of ALARA for OARs without compromising target coverage. The dose-volume parameters, conformity index (CI) and homogeneity index (HI) were compared for IMRT versus IMPT using student's t-test. Target volume coverage was well achieved with both IMRT and IMPT. However, V100% of GTVp and GTVn and V95%, V98%, V99%, V100% of CTVPelvis and CTVTumourBoost were significantly better with IMPT. HI and CI of target volumes were also significantly improved with IMPT. There was a significant decrease in volume of OARs receiving doses <40 Gy. Volumes receiving higher doses (40-50 Gy) were very small and not significantly affected with use of IMPT. IMPT offers improved target coverage with reduction in low-intermediate dose spill to OARs. Based on these results, dose constraints for IMPT planning have been generated for future clinical trial validation.
SN  - 2331-5180
ER  -