Improving Accuracy and Evaluating the Generalizability of Medical Image Classification Using Pseudo-Invisible-Light Images Generated from RGB Images.
- 1Graduate School of Bionics, Computer and Media Science, Tokyo University of Technology, 1404-1 Katakuramachi, Hachioji, Tokyo 192-0982, Japan.
- 2School of Computer Science, Tokyo University of Technology, 1404-1 Katakuramachi, Hachioji, Tokyo 192-0982, Japan.
Abstract
We extend our previous study on extended 5-channel images, which add two pseudo-invisible-light channels, estimated by spectral reconstruction (MST++) and polynomial extrapolation, to the RGB channels. We first ask whether the accuracy gain reflects prior knowledge contributed by the externally trained spectral-reconstruction model or effects that any 5-channel input derived from RGB would produce. For skin cancer classification with a CNN trained from scratch, the proposed input is compared with grayscale-based extensions, duplicated RGB channels, learned pointwise transforms of RGB, and learned projections of the reconstructed spectrum. Duplicating RGB channels alone raised accuracy from 86.49% to 88.27%; learned transforms of RGB did not significantly exceed this level, whereas the proposed input (89.94%) exceeded both; learned projections of the reconstructed spectrum did not differ significantly from it. We then re-evaluate the method on diabetic retinopathy, gastrointestinal, and glaucoma classification with ImageNet-pretrained ResNet50, with wavelengths selected on validation data. The proposed input exceeded RGB by 1.5-2.1 percentage points in all three tasks, as did most wavelength combinations, but these gains were not significant and not distinguishable from the RGB-duplication control; an effect specific to the proposed input remains unestablished there. Computational cost is also reported.
Related
- Evaluating the Efficacy of Comprehensive Nursing Care in Improving the Well-Being of Patients With Colon Cancer Who Developed Postoperative Sleep Disorders
- Results from a Phase II Single Arm Trial Evaluating the Safety and Efficacy of Anhydrous Enol-Oxaloacetate on Improving Cognitive Complaints in Breast Cancer Survivors
- Evaluating the reliability, quality, and readability of AI-generated patient education on hallux valgus: a comparative study of large language models
- Protocol: WorkoutCPP - a pilot series of N-of-1 trials evaluating RL-generated adaptive exercise recommendations for pelvic pain management
- Distribution and Clinical Utility of the Kidney Disease Improving Global Outcomes Chronic Kidney Disease Risk Classification in Patients Undergoing Atrial Fibrillation Ablation
BibTeX
@article{fuse2026improving,
title = {{Improving Accuracy and Evaluating the Generalizability of Medical Image Classification Using Pseudo-Invisible-Light Images Generated from RGB Images.}},
author = {Ryota Fuse and Terumasa Aoki and Ryohei Sasaki},
journal = {Journal of imaging},
year = {2026},
month = nov,
doi = {10.3390/jimaging12110556},
url = {https://europepmc.org/article/MED/43082946},
note = {CC BY},
}
RIS
TY - JOUR
TI - Improving Accuracy and Evaluating the Generalizability of Medical Image Classification Using Pseudo-Invisible-Light Images Generated from RGB Images.
AU - Ryota Fuse
AU - Terumasa Aoki
AU - Ryohei Sasaki
PY - 2026
DA - 2026/11/06
JO - Journal of imaging
DO - 10.3390/jimaging12110556
UR - https://europepmc.org/article/MED/43082946
AB - We extend our previous study on extended 5-channel images, which add two pseudo-invisible-light channels, estimated by spectral reconstruction (MST++) and polynomial extrapolation, to the RGB channels. We first ask whether the accuracy gain reflects prior knowledge contributed by the externally trained spectral-reconstruction model or effects that any 5-channel input derived from RGB would produce. For skin cancer classification with a CNN trained from scratch, the proposed input is compared with grayscale-based extensions, duplicated RGB channels, learned pointwise transforms of RGB, and learned projections of the reconstructed spectrum. Duplicating RGB channels alone raised accuracy from 86.49% to 88.27%; learned transforms of RGB did not significantly exceed this level, whereas the proposed input (89.94%) exceeded both; learned projections of the reconstructed spectrum did not differ significantly from it. We then re-evaluate the method on diabetic retinopathy, gastrointestinal, and glaucoma classification with ImageNet-pretrained ResNet50, with wavelengths selected on validation data. The proposed input exceeded RGB by 1.5-2.1 percentage points in all three tasks, as did most wavelength combinations, but these gains were not significant and not distinguishable from the RGB-duplication control; an effect specific to the proposed input remains unestablished there. Computational cost is also reported.
SN - 2313-433X
ER -