Skip to content
DraconiticResearch
Search Sources API
277,308 studies31 sourcesUpdated 47 min ago
Peer-reviewedCC BYRSC advances

Paper-based hydrogel biosensor integrated with carbon dots for portable detection of microRNA-21 using a fluorescent diffusion area as the readout.

6 affiliations
  1. 1Department of Nephrology, Fuzong Clinical Medical College of Fujian Medical University Fuzhou Fujian 350025 China [email protected].
  2. 2Department of Nephrology, 900th Hospital of PLA Joint Logistic Support Force 156 Xierhuan Northern Road Fuzhou Fujian 350025 China.
  3. 3Department of Cardiology, Fuzong Teaching Hospital of Fujian University of Traditional Chinese Medicine 156 Xierhuan Northern Road Fuzhou Fujian 350025 China.
  4. 4Ministry of Education, Key Laboratory for Analytical Science of Food Safety and Biology, College of Chemistry, Fuzhou University Fuzhou 350116 Fujian China [email protected].
  5. 5Institute for Advanced Study, Research Center for Differentiation and Development of TCM Basic Theory, Jiangxi University of Chinese Medicine Nanchang 330004 Jiangxi China.
  6. 6Health Medicine Department, 900th Hospital of PLA Joint Logistic Support Force 156 Xierhuan Northern Road Fuzhou Fujian 350025 China [email protected].

Abstract

The early detection of diabetic kidney disease (DKD) is limited by the lack of suitable biomarkers. Circulating microRNA-21 (miR-21), a key pathogenic regulator correlated with early injury, presents a promising solution for point-of-care testing. In this work, a paper-based hydrogel biosensor that relies on fluorescent areas as the readout has been constructed for the convenient and ultrasensitive quantification of miR-21. The miR-21-responsive water-absorption hydrogel loaded with carbon dots (CDs) synthesized by sodium hyaluronate and the complementary capturing DNA (cDNA) of miR-21 is constructed for fluorescent area generation on filter paper. The miR-21 can be captured by the cDNA in a hydrogel, and the cDNA in the miR-21-cDNA duplex is cleaved by a duplex-specific nuclease. Then, the released miR-21 can be captured by other cDNA, thereby achieving signal amplification. The hydrogel was degraded via the cleavage of cDNA, and the CD-containing water was then released from the hydrogel fragments and spread uniformly on filter paper, thereby forming a distinct fluorescent region. The fluorescent area can be imaged by a smartphone and quantified via the pixel ratio of the fluorescent region to the whole paper area, which is then converted to the actual physical area. The developed biosensor demonstrates a linear response to miR-21 ranging from 1 pM to 10 nM with a detection limit of 131.25 fM. The portable sensing method exhibits portability, convenience, and high selectivity and has been applied to detect miR-21 in serum samples with satisfactory results, showing promising potential for early DKD screening.

Related

  1. An electrochemical biosensor based on antifouling conductive hydrogel for umami detection in complex fish matrices
    Mengjie Qin, Yuanyuan Luo, Feng Hong +6
    Food Chemistry: XPeer-reviewedCC BY-NC-ND 4.0Full textAnalytical chemistryPMC
  2. Electrochemical detection of hepatitis B virus DNA: a biosensor based on MnO2/MWCNT/AgNPs composite material
    Yuzhen Zhu, Ying Huang, Nicole Jaffrezic-Renault +2
    PolyhedronPeer-reviewedLicence not statedGeneral chemistryHAL
  3. Miniaturized biosensor platforms for early detection of neurodegenerative diseases and their potential for clinical translation
    İnci Uludağ Anıl, Buse Sancaklı, Nicole Jaffrezic-Renault +2
    Discover ElectrochemistryPeer-reviewedCC BY-NC-ND 4.0Full textGeneral chemistryHAL
  4. Cardiolipin-Based Electrochemical Biosensor for Non-treponemal Antibody Detection Using Screen-Printed Electrodes: A Proof-of-Concept Study
    Duane da Silva Moraes, Bruna Ferri Serafini, Felipe Longaray Kadel +5
    ACS OmegaPeer-reviewedCC BY 4.0Full textGeneral chemistryCrossrefPMC
  5. Filtration-Enhanced Dual-Mode SERS Biosensor for Rapid On-Tap Detection of Waterborne Pathogens in Drinking Water.
    Zixuan Ma, Mengdong Liu, Hongbo Zhang +4
    BiosensorsPeer-reviewedCC BYFull textMaterials & polymersEurope PMC
BibTeX
@article{chen2026paperbased,
  title = {{Paper-based hydrogel biosensor integrated with carbon dots for portable detection of microRNA-21 using a fluorescent diffusion area as the readout.}},
  author = {Xiaoqing Chen and Wansheng Lin and Qiang Lin and Bin Qiu and Zhixin Li and Chunjian Ye and Jianqing Liu},
  journal = {RSC advances},
  year = {2026},
  month = nov,
  doi = {10.1039/d6ra07875c},
  url = {https://europepmc.org/article/MED/43075244},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - Paper-based hydrogel biosensor integrated with carbon dots for portable detection of microRNA-21 using a fluorescent diffusion area as the readout.
AU  - Xiaoqing Chen
AU  - Wansheng Lin
AU  - Qiang Lin
AU  - Bin Qiu
AU  - Zhixin Li
AU  - Chunjian Ye
AU  - Jianqing Liu
PY  - 2026
DA  - 2026/11/23
JO  - RSC advances
DO  - 10.1039/d6ra07875c
UR  - https://europepmc.org/article/MED/43075244
AB  - The early detection of diabetic kidney disease (DKD) is limited by the lack of suitable biomarkers. Circulating microRNA-21 (miR-21), a key pathogenic regulator correlated with early injury, presents a promising solution for point-of-care testing. In this work, a paper-based hydrogel biosensor that relies on fluorescent areas as the readout has been constructed for the convenient and ultrasensitive quantification of miR-21. The miR-21-responsive water-absorption hydrogel loaded with carbon dots (CDs) synthesized by sodium hyaluronate and the complementary capturing DNA (cDNA) of miR-21 is constructed for fluorescent area generation on filter paper. The miR-21 can be captured by the cDNA in a hydrogel, and the cDNA in the miR-21-cDNA duplex is cleaved by a duplex-specific nuclease. Then, the released miR-21 can be captured by other cDNA, thereby achieving signal amplification. The hydrogel was degraded via the cleavage of cDNA, and the CD-containing water was then released from the hydrogel fragments and spread uniformly on filter paper, thereby forming a distinct fluorescent region. The fluorescent area can be imaged by a smartphone and quantified via the pixel ratio of the fluorescent region to the whole paper area, which is then converted to the actual physical area. The developed biosensor demonstrates a linear response to miR-21 ranging from 1 pM to 10 nM with a detection limit of 131.25 fM. The portable sensing method exhibits portability, convenience, and high selectivity and has been applied to detect miR-21 in serum samples with satisfactory results, showing promising potential for early DKD screening.
SN  - 2046-2069
ER  -