Flow-S enables field-based detection of low-intensity Schistosoma infections for monitoring and evaluation of control programs
4 affiliations
- 1Department of Cell and Chemical Biology, Leiden University Medical Center , ,
- 2Salus Discovery LLC , , ,
- 3Mwanza Intervention Trials Unit, National Institute for Medical Research , ,
- 4Leiden University Center for Infectious Diseases, Leiden University Medical Center , ,
Abstract
Introduction
Schistosomiasis remains a major public health challenge, particularly in sub-Saharan Africa. Detecting low-intensity infections is difficult because conventional parasitological methods lack sufficient sensitivity. Circulating anodic antigen (CAA), a genus-specific biomarker released by Schistosoma worms, enables detection of active Schistosoma infections. However, existing CAA assays require laboratory-based sample processing. We evaluated Flow-S, a field-deployable device for high-sensitivity quantitative CAA detection directly from large-volume, untreated urine samples. Flow-S integrates CAA concentration and quantitative upconverting reporter particle lateral flow (UCP-LF) detection with a portable standalone battery-powered reader for field-use.Methods
A prospective study was conducted by local healthcare staff in a remote Schistosoma haematobium-endemic low-to-moderate infection setting. Fresh urine samples (n = 158) from women of reproductive age were analyzed using Flow-S. Paired urine, serum, and stool samples were examined by urine filtration microscopy, Kato-Katz (to exclude S. mansoni), and laboratory-based UCP-LF CAA reference assays (serum SCAA20 and urine UCAAhT417). A composite reference standard (CRS) classified individuals as infected when eggs or either reference CAA assay was positive. Flow-S performance was evaluated against the CRS and further assessed using latent class analysis (LCA).Results
Complete datasets were available for 115 samples. Flow-S achieved an area under the receiver operating characteristic (ROC) curve of 0.92 and detected all egg-positive infections. Using a positivity threshold of 1.10 pg/mL, Flow-S achieved 80.8% sensitivity and 96.6% specificity, meeting the World Health Organization ideal target product profile requirements for monitoring and evaluation of schistosomiasis control programs. Latent class analysis provided complementary model-based evidence consistent with the high discriminatory performance of Flow-S observed using the composite reference standard.Conclusions
Flow-S enables quantitative, field-deployable detection of S. haematobium infections directly from untreated large-volume urine without laboratory pre-treatment. Its high analytical sensitivity and diagnostic performance support its potential for detecting low-intensity infections. At an operational threshold of 1.10 pg/mL, Flow-S met the WHO TPP ideal targets for monitoring and evaluation and showed potential for cost-effective surveillance strategies, including pooled-sample screening for schistosomiasis control and elimination programs.
Related
- Associations between Inflammation-Adjusted Vitamin A Status and Schistosoma japonicum Infection Intensity among Children and Adolescents in The Philippines: A Cross-Sectional Study
- Application and evaluation of nanopore targeted sequencing in the detection of bacterial and fungal pathogens in leukemia bloodstream infections.
- From first contact to challenge: Lung immune modulation by single-sex Schistosoma mansoni infections
- From Enzyme to Parasite: Enzymatic and Phenotypic-Guided Evaluation of Repurposed Inhibitors against Schistosoma mansoni cathepsin D1 (SmCD1)
- Development, characterization, and immunomodulatory evaluation of a liposomal DNA vaccine targeting Schistosoma mansoni IPSE/α-1
BibTeX
@article{jong2026flows,
title = {{Flow-S enables field-based detection of low-intensity Schistosoma infections for monitoring and evaluation of control programs}},
author = {Daniëlle de Jong and Cody Carrell and Jane K. Maganga and Peter S. Shigella and Loyce Mhango and Pytsje T. Hoekstra and Govert J. van Dam and Brianna Mullins and John M. Changalucha and Jennifer A. Downs and Jay W. Warrick and Paul L. A. M. Corstjens},
journal = {Frontiers in parasitology},
year = {2026},
month = nov,
doi = {10.3389/fpara.2026.1974692},
url = {https://europepmc.org/article/PMC/PMC13793477},
note = {CC BY},
}
RIS
TY - JOUR
TI - Flow-S enables field-based detection of low-intensity Schistosoma infections for monitoring and evaluation of control programs
AU - Daniëlle de Jong
AU - Cody Carrell
AU - Jane K. Maganga
AU - Peter S. Shigella
AU - Loyce Mhango
AU - Pytsje T. Hoekstra
AU - Govert J. van Dam
AU - Brianna Mullins
AU - John M. Changalucha
AU - Jennifer A. Downs
AU - Jay W. Warrick
AU - Paul L. A. M. Corstjens
PY - 2026
DA - 2026/11/10
JO - Frontiers in parasitology
DO - 10.3389/fpara.2026.1974692
UR - https://europepmc.org/article/PMC/PMC13793477
AB - Introduction Schistosomiasis remains a major public health challenge, particularly in sub-Saharan Africa. Detecting low-intensity infections is difficult because conventional parasitological methods lack sufficient sensitivity. Circulating anodic antigen (CAA), a genus-specific biomarker released by Schistosoma worms, enables detection of active Schistosoma infections. However, existing CAA assays require laboratory-based sample processing. We evaluated Flow-S, a field-deployable device for high-sensitivity quantitative CAA detection directly from large-volume, untreated urine samples. Flow-S integrates CAA concentration and quantitative upconverting reporter particle lateral flow (UCP-LF) detection with a portable standalone battery-powered reader for field-use.Methods A prospective study was conducted by local healthcare staff in a remote Schistosoma haematobium-endemic low-to-moderate infection setting. Fresh urine samples (n = 158) from women of reproductive age were analyzed using Flow-S. Paired urine, serum, and stool samples were examined by urine filtration microscopy, Kato-Katz (to exclude S. mansoni), and laboratory-based UCP-LF CAA reference assays (serum SCAA20 and urine UCAAhT417). A composite reference standard (CRS) classified individuals as infected when eggs or either reference CAA assay was positive. Flow-S performance was evaluated against the CRS and further assessed using latent class analysis (LCA).Results Complete datasets were available for 115 samples. Flow-S achieved an area under the receiver operating characteristic (ROC) curve of 0.92 and detected all egg-positive infections. Using a positivity threshold of 1.10 pg/mL, Flow-S achieved 80.8% sensitivity and 96.6% specificity, meeting the World Health Organization ideal target product profile requirements for monitoring and evaluation of schistosomiasis control programs. Latent class analysis provided complementary model-based evidence consistent with the high discriminatory performance of Flow-S observed using the composite reference standard.Conclusions Flow-S enables quantitative, field-deployable detection of S. haematobium infections directly from untreated large-volume urine without laboratory pre-treatment. Its high analytical sensitivity and diagnostic performance support its potential for detecting low-intensity infections. At an operational threshold of 1.10 pg/mL, Flow-S met the WHO TPP ideal targets for monitoring and evaluation and showed potential for cost-effective surveillance strategies, including pooled-sample screening for schistosomiasis control and elimination programs.
SN - 2813-2424
ER -