Skip to content
DraconiticResearch
Search Sources API
276,906 studies31 sourcesUpdated 21 min ago
Peer-reviewedCC BYBiosensors

Rapid Protein and Mineral Characterization of Pea Flour Using QCL-MIR and LIBS Combined with UVE-PLS-ELM Machine Learning Framework.

  1. 1InstitutNational de la Recherche Scientifique, Centre Énergie Matériaux Télécommunications, 1650 Lionel-Boulet Blvd., Varennes, QC J3X 1P7, Canada.
  2. 2Aquatic and Crop Resource Development, National Research Council of Canada, 110 Gymnasium Place, Saskatoon, SK S7N 0W9, Canada.
  3. 3Clean Energy Innovation Research Centre, National Research Council of Canada, 75 de Mortagne Blvd., Boucherville, QC J4B 6Y4, Canada.

Abstract

Rapid quantitative characterization of protein-rich agricultural materials remains challenging due to the molecular and elemental complexity of plant-derived matrices. In this study, external-cavity quantum cascade laser-based mid-infrared (QCL-MIR) spectroscopy and laser-induced breakdown spectroscopy (LIBS) were investigated as complementary approaches for predicting protein and elemental composition in pea flour (Pisum sativum L.) samples. QCL-MIR spectroscopy primarily probed molecular vibrational information, whereas LIBS directly monitored elemental composition through plasma-generated atomic and ionic emission signatures. To address the high dimensionality and nonlinear relationships present in both spectroscopic datasets, advanced chemometric strategies combining Uninformative Variable Elimination (UVE), Partial Least Squares (PLS) regression, and Extreme Learning Machine (ELM) modeling were implemented. Given the limited dataset size (N = 20), predictive performance was assessed using a concentration-stratified five-fold prediction strategy. The optimized UVE-PLS-ELM approach improved predictive performance compared with conventional linear PLS models for both techniques. QCL-MIR spectroscopy showed strong predictive performance within the present dataset for total protein content (R² = 0.97) and also provided promising predictions of phosphorus and potassium through indirect correlations with sample composition. LIBS also demonstrated strong calibration and predictive capability for total protein content (R² = 0.93) and good predictive performance for Na, Mg, Ca, Mn, and Fe. However, LIBS performance decreased at concentration extremes, particularly for high-concentration elements (K and P) and trace elements such as Zn and Cu. These results demonstrate the complementary strengths of QCL-MIR and LIBS and highlight the potential of nonlinear chemometric approaches for accurate compositional analysis of protein-rich agricultural materials within the present limited dataset.

Related

  1. MMAllo: a multimodal deep learning framework and GaMD simulations for predicting protein allosteric sites and allosteric mutations.
    Pengyin Zhang, Yi He, Hanwen Liu +2
    Journal of cheminformaticsPeer-reviewedCC BY-NC-NDFull textMedicinal chemistry & drug discoveryEurope PMCPMC
  2. Impact of emollients on the spreading properties of cosmetic products: A combined sensory and instrumental characterization
    Géraldine Savary, Michel Grisel, Celine Picard
    Colloids and Surfaces B: BiointerfacesPeer-reviewedPublisher termsFull text132 citedAnalytical chemistryMaterials & polymersHAL
  3. Machine Learning Identifies an Information-Sufficiency Regime for Critical-Mineral Recovery
    Tengxiao Liu, Ta-Wei Wang, Hongtao Sun
    ChemRxivPreprintCC BYFull textGeneral chemistryChemRxiv
  4. Advancing specific local wine identification through integration of ICP-MS mineral wine profiles and Machine Learning: A case study on discrimination among the ten Beaujolais crus
    Yohann Clément, Pierre Lantéri, Agnès Hagège +6
    TalantaPeer-reviewedCC BY-NC-ND 4.0Full text2 citedGeneral biologyAnalytical chemistryHAL
  5. Gas Phase Charge Reduction for Improved Protein Characterization by Mass Spectrometry
    Sachin C. Tennakoon, Lasini Amunugama, Jared B. Shaw
    Analytica chimica actaPeer-reviewedLicence not statedFull textPhysical chemistryPMC
BibTeX
@article{sabsabi2026rapid,
  title = {{Rapid Protein and Mineral Characterization of Pea Flour Using QCL-MIR and LIBS Combined with UVE-PLS-ELM Machine Learning Framework.}},
  author = {Jinan Sabsabi and Andressa Adame and Bianyun Yu and Francis Vanier and Christian Padioleau and Nii Patterson and Allan Feurtado and Samira Selmani and Mohamad Sabsabi and François Vidal},
  journal = {Biosensors},
  year = {2026},
  month = oct,
  doi = {10.3390/bios16110594},
  url = {https://europepmc.org/article/MED/43082489},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - Rapid Protein and Mineral Characterization of Pea Flour Using QCL-MIR and LIBS Combined with UVE-PLS-ELM Machine Learning Framework.
AU  - Jinan Sabsabi
AU  - Andressa Adame
AU  - Bianyun Yu
AU  - Francis Vanier
AU  - Christian Padioleau
AU  - Nii Patterson
AU  - Allan Feurtado
AU  - Samira Selmani
AU  - Mohamad Sabsabi
AU  - François Vidal
PY  - 2026
DA  - 2026/10/22
JO  - Biosensors
DO  - 10.3390/bios16110594
UR  - https://europepmc.org/article/MED/43082489
AB  - Rapid quantitative characterization of protein-rich agricultural materials remains challenging due to the molecular and elemental complexity of plant-derived matrices. In this study, external-cavity quantum cascade laser-based mid-infrared (QCL-MIR) spectroscopy and laser-induced breakdown spectroscopy (LIBS) were investigated as complementary approaches for predicting protein and elemental composition in pea flour (Pisum sativum L.) samples. QCL-MIR spectroscopy primarily probed molecular vibrational information, whereas LIBS directly monitored elemental composition through plasma-generated atomic and ionic emission signatures. To address the high dimensionality and nonlinear relationships present in both spectroscopic datasets, advanced chemometric strategies combining Uninformative Variable Elimination (UVE), Partial Least Squares (PLS) regression, and Extreme Learning Machine (ELM) modeling were implemented. Given the limited dataset size (N = 20), predictive performance was assessed using a concentration-stratified five-fold prediction strategy. The optimized UVE-PLS-ELM approach improved predictive performance compared with conventional linear PLS models for both techniques. QCL-MIR spectroscopy showed strong predictive performance within the present dataset for total protein content (R² = 0.97) and also provided promising predictions of phosphorus and potassium through indirect correlations with sample composition. LIBS also demonstrated strong calibration and predictive capability for total protein content (R² = 0.93) and good predictive performance for Na, Mg, Ca, Mn, and Fe. However, LIBS performance decreased at concentration extremes, particularly for high-concentration elements (K and P) and trace elements such as Zn and Cu. These results demonstrate the complementary strengths of QCL-MIR and LIBS and highlight the potential of nonlinear chemometric approaches for accurate compositional analysis of protein-rich agricultural materials within the present limited dataset.
SN  - 2079-6374
ER  -