Application of the visual extra-endoscopic scraper in endoscopic lumbar interbody fusion: a technical note and preliminary results
10 affiliations
- 1Department of Orthopedics, Suzhou TCM Hospital Affiliated to Nanjing University of Chinese Medicine, Suzhou, 215009 China
- 2Nanjing University of Chinese Medicine, Nanjing, 210023 China
- 3Guangzhou University of Chinese Medicine, Guangzhou, 510405 China
- 4Department of Spinal Surgery, The First Affiliated Hospital of Guangzhou University of Traditional Chinese Medicine, Guangzhou, 510405 China
- 5Shanghai Municipal Hospital of Traditional Chinese Medicine, Shanghai University of Traditional Chinese Medicine, Shanghai, 201203 China
- 6Guizhou University of Traditional Chinese Medicine, Guiyang, 550000 China
- 7Medical Department, Dalian University of Technology, Dalian, 116024 China
- 8The Second Affiliated Hospital, Guangzhou Medical University, Guangzhou, Guangdong Province 510260 China
- 9Guangzhou Medical University, Guangzhou, 511436 China
- 10The Affiliated TCM Hospital of Guangzhou Medical University, Guangzhou, 510130 China
Abstract
Background: The visualization operation of spine surgery is very important, especially in minimally invasive surgery. We introduce the Visual Extra-endoscopic Scraper (VES) as a substitute for traditional instruments such as the working channel, intervertebral reamer, and curette in Endo-LIF through the technical note and preliminary results.
Methods: The VES, featuring a sharp lower-end opening for rotating cutting, is used under direct endoscopic visualization during intervertebral disc excision and bone graft bed preparation. We conducted a retrospective analysis of 26 patients who underwent Endo-LIF with the VES. Key parameters assessed included the time required to process the intervertebral space with the VES, overall surgical duration, visual analogue scale (VAS) pain scores for the back and legs, Oswestry Disability Index (ODI), Japanese Orthopaedic Association (JOA) scores at preoperative, postoperative, 6-month postoperative, and final follow-up, as well as evaluations of intervertebral fusion and associated complications.
Results: Patients treated with Endo-LIF had an average time of 17.90 ± 4.5 min for using the VES to remove intervertebral discs and prepare the bone graft bed during surgery. The total surgery time was 169.19 ± 24.90 min, with the VES accounting for 10.69 ± 2.71% of the total surgery time. Intraoperative blood loss was 50 (20, 85) ml, and the length of postoperative hospital stay was 4 (3, 7) days. Significant improvements were observed in clinical outcomes, including VAS scores for the waist and legs, ODI scores, and JOA scores at various postoperative time points compared to preoperative values (P < 0.05).
Conclusion: The VES in Endo-LIF surgery for treating lumbar degenerative diseases demonstrates significant value by reducing procedure time under endoscopic direct vision. It improves the efficiency of discectomy and bone graft bed preparation and reduces neuro-related complications.
Trial registration: The study was approved by the ethics committee of the First Affiliated Hospital of Guangzhou University of Chinese Medicine (NO. JY2022-133).
Related
- Anchored Drill-Assisted Localization for Percutaneous Endoscopic Cervical Keyhole Surgery in the Treatment of Cervical Spondylotic Radiculopathy: A Technical Report and Preliminary Efficacy Evaluation
- Application of continuous intraoperative neuromonitoring (C-IONM) for recurrent laryngeal nerve preservation in transoral endoscopic thyroidectomy: a preliminary report from Vietnam.
- A Commentary on “Endoscopic Lumbar Interbody Fusion Versus Minimally Invasive Transforaminal Lumbar Interbody Fusion: A Structured Debate and International Practice Patterns”
- Radiological decompression and clinical outcomes following endoscopic unilateral biportal lumbar interbody fusion vs. conventional posterior lumbar interbody fusion.
- Endoscopic Lumbar Interbody Fusion Versus Minimally Invasive Transforaminal Lumbar Interbody Fusion: A Structured Debate and International Practice Patterns
BibTeX
@article{zhuo2026application,
title = {{Application of the visual extra-endoscopic scraper in endoscopic lumbar interbody fusion: a technical note and preliminary results}},
author = {Hang Zhuo and Hao Liu and Wanyan Chen and Zelin Zhou and Zhilin Ge and Xingda Chen and Feng Lin and Zefeng Song and Riwei Tan and Bin Xie and De Liang and Hui Ren and Gengyang Shen and Jiahui He and Jingjing Tang and Xiaobing Jiang},
journal = {BMC Musculoskeletal Disorders},
year = {2026},
month = aug,
doi = {10.1186/s12891-026-10341-x},
url = {https://doi.org/10.1186/s12891-026-10341-x},
note = {CC BY-NC-ND 4.0},
}
RIS
TY - JOUR
TI - Application of the visual extra-endoscopic scraper in endoscopic lumbar interbody fusion: a technical note and preliminary results
AU - Hang Zhuo
AU - Hao Liu
AU - Wanyan Chen
AU - Zelin Zhou
AU - Zhilin Ge
AU - Xingda Chen
AU - Feng Lin
AU - Zefeng Song
AU - Riwei Tan
AU - Bin Xie
AU - De Liang
AU - Hui Ren
AU - Gengyang Shen
AU - Jiahui He
AU - Jingjing Tang
AU - Xiaobing Jiang
PY - 2026
DA - 2026/08/17
JO - BMC Musculoskeletal Disorders
DO - 10.1186/s12891-026-10341-x
UR - https://doi.org/10.1186/s12891-026-10341-x
AB - Background: The visualization operation of spine surgery is very important, especially in minimally invasive surgery. We introduce the Visual Extra-endoscopic Scraper (VES) as a substitute for traditional instruments such as the working channel, intervertebral reamer, and curette in Endo-LIF through the technical note and preliminary results. Methods: The VES, featuring a sharp lower-end opening for rotating cutting, is used under direct endoscopic visualization during intervertebral disc excision and bone graft bed preparation. We conducted a retrospective analysis of 26 patients who underwent Endo-LIF with the VES. Key parameters assessed included the time required to process the intervertebral space with the VES, overall surgical duration, visual analogue scale (VAS) pain scores for the back and legs, Oswestry Disability Index (ODI), Japanese Orthopaedic Association (JOA) scores at preoperative, postoperative, 6-month postoperative, and final follow-up, as well as evaluations of intervertebral fusion and associated complications. Results: Patients treated with Endo-LIF had an average time of 17.90 ± 4.5 min for using the VES to remove intervertebral discs and prepare the bone graft bed during surgery. The total surgery time was 169.19 ± 24.90 min, with the VES accounting for 10.69 ± 2.71% of the total surgery time. Intraoperative blood loss was 50 (20, 85) ml, and the length of postoperative hospital stay was 4 (3, 7) days. Significant improvements were observed in clinical outcomes, including VAS scores for the waist and legs, ODI scores, and JOA scores at various postoperative time points compared to preoperative values (P < 0.05). Conclusion: The VES in Endo-LIF surgery for treating lumbar degenerative diseases demonstrates significant value by reducing procedure time under endoscopic direct vision. It improves the efficiency of discectomy and bone graft bed preparation and reduces neuro-related complications. Trial registration: The study was approved by the ethics committee of the First Affiliated Hospital of Guangzhou University of Chinese Medicine (NO. JY2022-133).
SN - 1471-2474
ER -