Feasibility of Wearable Heart Rate Variability Monitoring During a Military Closed-Circuit Rebreather Dive: An Exploratory Case Report.
12 affiliations
- 1The Divers and Special Forces Group of the Italian Navy-Le Grazie/Portovenere (SP), 19025 Portovenere, SP, Italy.
- 2The Italian Diving and Hyperbaric Medical Society (SIMSI), 48100 Ravenna, RA, Italy.
- 3Extreme Center, Scuola Superiore Sant'Anna, 56127 Pisa, PI, Italy.
- 4TrancriLab, Laboratory of Basic and Applied Medical Research, Interdisciplinary Research Center "Health Science", Scuola Superiore Sant'Anna, 56127 Pisa, PI, Italy.
- 5UOSVD Anesthesia and Intensive Care, Fondazione Toscana "G. Monasterio", 56124 Pisa, PI, Italy.
- 6Military Hospital, 19122 La Spezia, SP, Italy.
- 7Inspectorate of the Italian Navy, 00100 Rome, RM, Italy.
- 8Institute of Clinical Physiology, National Research Council, 54100 Massa, MS, Italy.
- 9International School of Advanced Studies, University of Camerino, 62032 Camerino, MC, Italy.
- 10Department of Surgical, Medical and Molecular Pathology and Critical Care Medicine, University of Pisa, 56126 Pisa, PI, Italy.
- 11Department of Ophthalmology, Riga Stradins University, LV-1007 Riga, Latvia.
- 12Faculty for Human Sciences, Pegaso University, 00187 Rome, RM, Italy.
Abstract
Background: Heart rate variability (HRV) monitoring during real-world closed-circuit rebreather (CCR) diving remains methodologically challenging. This exploratory case report describes phase-related HRV variations obtained from a wearable device during a military CCR dive. Methods: A trained male military diver underwent continuous monitoring with a RootiRx® single-lead wearable device placed in a custom waterproof enclosure. Three consecutive 20 min segments were analyzed: pre-dive, CCR dive, and immediate post-dive. The post-dive segment was not acquired under standardized resting conditions, and the participant continued to wear the device throughout this period. RR interval data were analyzed using Kubios HRV Scientific 4.3.0 with medium-threshold artifact correction, smoothness-prior detrending (λ = 500), and 4 Hz interpolation. Time-domain, frequency-domain, and nonlinear HRV indices were evaluated descriptively. Results: Mean heart rate was 88.1 beats/min pre-dive, 102.8 beats/min during the dive, and 86.4 beats/min post-dive. SDNN values were 35.3, 29.9, and 49.2 ms, while RMSSD values were 29.7, 24.6, and 40.3 ms, respectively. The PNS index was -1.44, -2.08, and -1.10, and the SNS index was 1.66, 2.98, and 1.26 across the three phases. LF/HF values were 1.77, 1.46, and 3.92, respectively. Automatically corrected beats represented approximately 0.34%, 0.54%, and 0.46% of beats, with effective analyzable data proportions exceeding 99.7% in all three segments. Conclusions: An analyzable RR interval series was obtained across the three operational phases in this individual recording. However, the single-subject uncontrolled design, non-standardized recording conditions, multiple confounding factors, and absence of independent underwater validation prevent causal attribution of the observed differences to immersion, CCR exposure, or autonomic adaptation. Further controlled studies using validated underwater ECG systems are required.
Related
- A wearable perspiration biosensor for continuous biomarker monitoring in inflammatory bowel disease: Feasibility, concordance, and exploratory temporal dynamics
- Usability and feasibility of a wearable sensor-based monitoring system providing feedback on sedentary behaviour during inpatient and home-based geriatric rehabilitation
- Wearable Heart Rate Variability Monitoring, Autonomic Dysfunction and Post-exertional Malaise in Long COVID: An Observational Study
- A randomised feasibility trial of VR-enhanced cue exposure therapy versus neutral VR exposure for cocaine use disorder, with wearable monitoring and JITA-EMA: Feasibility randomised controlled trial protocol
- Prospective digital neurocognitive and patient-reported symptom monitoring in adults scheduled for CAR T-cell therapy: feasibility and exploratory patient-level observations from a single-center cohort
BibTeX
@article{moccia2026feasibility,
title = {{Feasibility of Wearable Heart Rate Variability Monitoring During a Military Closed-Circuit Rebreather Dive: An Exploratory Case Report.}},
author = {Enrico Moccia and Vincenzo Lionetti and Gabriele Lombardi and Fabio Di Pumpo and Lorenzo Rondinini and Luca Bastiani and Vincenzo Rizzuto and Giorgio Giuliano and Gualtiero Meloni},
journal = {Journal of functional morphology and kinesiology},
year = {2026},
month = oct,
doi = {10.3390/jfmk11040440},
url = {https://europepmc.org/article/MED/43081340},
note = {CC BY},
}
RIS
TY - JOUR
TI - Feasibility of Wearable Heart Rate Variability Monitoring During a Military Closed-Circuit Rebreather Dive: An Exploratory Case Report.
AU - Enrico Moccia
AU - Vincenzo Lionetti
AU - Gabriele Lombardi
AU - Fabio Di Pumpo
AU - Lorenzo Rondinini
AU - Luca Bastiani
AU - Vincenzo Rizzuto
AU - Giorgio Giuliano
AU - Gualtiero Meloni
PY - 2026
DA - 2026/10/23
JO - Journal of functional morphology and kinesiology
DO - 10.3390/jfmk11040440
UR - https://europepmc.org/article/MED/43081340
AB - Background: Heart rate variability (HRV) monitoring during real-world closed-circuit rebreather (CCR) diving remains methodologically challenging. This exploratory case report describes phase-related HRV variations obtained from a wearable device during a military CCR dive. Methods: A trained male military diver underwent continuous monitoring with a RootiRx® single-lead wearable device placed in a custom waterproof enclosure. Three consecutive 20 min segments were analyzed: pre-dive, CCR dive, and immediate post-dive. The post-dive segment was not acquired under standardized resting conditions, and the participant continued to wear the device throughout this period. RR interval data were analyzed using Kubios HRV Scientific 4.3.0 with medium-threshold artifact correction, smoothness-prior detrending (λ = 500), and 4 Hz interpolation. Time-domain, frequency-domain, and nonlinear HRV indices were evaluated descriptively. Results: Mean heart rate was 88.1 beats/min pre-dive, 102.8 beats/min during the dive, and 86.4 beats/min post-dive. SDNN values were 35.3, 29.9, and 49.2 ms, while RMSSD values were 29.7, 24.6, and 40.3 ms, respectively. The PNS index was -1.44, -2.08, and -1.10, and the SNS index was 1.66, 2.98, and 1.26 across the three phases. LF/HF values were 1.77, 1.46, and 3.92, respectively. Automatically corrected beats represented approximately 0.34%, 0.54%, and 0.46% of beats, with effective analyzable data proportions exceeding 99.7% in all three segments. Conclusions: An analyzable RR interval series was obtained across the three operational phases in this individual recording. However, the single-subject uncontrolled design, non-standardized recording conditions, multiple confounding factors, and absence of independent underwater validation prevent causal attribution of the observed differences to immersion, CCR exposure, or autonomic adaptation. Further controlled studies using validated underwater ECG systems are required.
SN - 2411-5142