Skip to content
DraconiticResearch
Search Sources API
197,768 studies31 sourcesUpdated 29 min ago
PreprintarXiv licencearXiv

Portable Vector NV-Diamond Magnetometer for Shot-Noise-Limited, Drift-Free Operation in Unshielded Environments

Abstract

Ensemble nitrogen-vacancy (NV) diamond magnetometers combine high sensitivity with vector-field reconstruction, but practical deployment is limited by errors arising from high-frequency laser noise during short-duration operations and slow-varying gain fluctuations and offset drift during long-term operation. Here, we present an integrated digital architecture for achieving NV magnetometry stability across distinct timescales. A dynamic differential readout continuously balances fluorescence and reference channels to suppress correlated laser noise. Second-derivative Lorentzian lineshape tracking enables in-situ correction of slope variations arising from slow changes in gain and optical excitation. We further identify temperature-induced bias-magnet fluctuations as a dominant source of long-term drift and introduce a magnetic eigenvector transformation that uses the intrinsic response of NV resonances to eliminate these variations. We show, under unshielded ambient conditions, that this architecture achieves an off-resonance noise factor of 1.0 ± 0.1, matching the fundamental limit with ten-fold suppression of long-term drift, enabling stable, field-ready quantum magnetometry.

Related

  1. Magnetic Particle Magnetometer Based on Langevin Response of Superparamagnetic Nanoparticles for Remote Magnetic Field Sensing
    M. Jurj, C. McDonough, C. Bastajian +1
    arXivPreprintCC BY 4.0Full textApplied physics & instrumentationarXiv
  2. Squeezing for dispersive readout of NV magnetometer
    A. M. Kozodaev, S. M. Drofa, P. G. Vilyuzhanina +9
    arXivPreprintarXiv licenceFull textQuantum physics & quantum informationarXiv
  3. In-situ Control of the Photon-Magnon Synchronized Mode in a Miniaturized Magnetometer
    Yuting Shi, Xudong Wang, Yue Zhao +5
    arXivPreprintarXiv licenceFull textApplied physics & instrumentationCondensed matterarXiv
  4. Cavity optomechanical magnetometer actuated by substrate bending
    D. D. Florizone, I. E. Rabuka, K. D. Hiltz +5
    arXivPreprintCC BY 4.0Full textApplied physics & instrumentationarXiv
  5. Dead-zone-free free-induction-decay alkali-metal atomic magnetometer
    X. -K. Wang, J. He, H. -H. Deng +2
    arXivPreprintCC BY-NC-ND 4.0Full textAtomic, molecular & optical physicsApplied physics & instrumentationarXiv
BibTeX
@misc{k2026portable,
  title = {{Portable Vector NV-Diamond Magnetometer for Shot-Noise-Limited, Drift-Free Operation in Unshielded Environments}},
  author = {Annirudh K P and Vinayak Rane and Shradha Atakar and Sanika Joshi and Maheshwar Mangat and Jay Gharat and Siddharth Tallur and Kasturi Saha},
  howpublished = {arXiv},
  year = {2026},
  month = sep,
  doi = {10.48550/arxiv.2609.16901},
  eprint = {2609.16901},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2609.16901},
}
RIS
TY  - UNPB
TI  - Portable Vector NV-Diamond Magnetometer for Shot-Noise-Limited, Drift-Free Operation in Unshielded Environments
AU  - Annirudh K P
AU  - Vinayak Rane
AU  - Shradha Atakar
AU  - Sanika Joshi
AU  - Maheshwar Mangat
AU  - Jay Gharat
AU  - Siddharth Tallur
AU  - Kasturi Saha
PY  - 2026
DA  - 2026/09/15
PB  - arXiv
DO  - 10.48550/arxiv.2609.16901
UR  - https://arxiv.org/abs/2609.16901
AB  - Ensemble nitrogen-vacancy (NV) diamond magnetometers combine high sensitivity with vector-field reconstruction, but practical deployment is limited by errors arising from high-frequency laser noise during short-duration operations and slow-varying gain fluctuations and offset drift during long-term operation. Here, we present an integrated digital architecture for achieving NV magnetometry stability across distinct timescales. A dynamic differential readout continuously balances fluorescence and reference channels to suppress correlated laser noise. Second-derivative Lorentzian lineshape tracking enables in-situ correction of slope variations arising from slow changes in gain and optical excitation. We further identify temperature-induced bias-magnet fluctuations as a dominant source of long-term drift and introduce a magnetic eigenvector transformation that uses the intrinsic response of NV resonances to eliminate these variations. We show, under unshielded ambient conditions, that this architecture achieves an off-resonance noise factor of 1.0 ± 0.1, matching the fundamental limit with ten-fold suppression of long-term drift, enabling stable, field-ready quantum magnetometry.
ER  -