Optical Acceptance Testing of Serenity-S1 Boards for the CMS HGCAL Phase-2 Backend Electronics
Abstract
The CMS Phase-2 upgrade includes a new high-granularity calorimeter. The calorimeter electronics will include around 300 Serenity-S1 FPGA boards that use Samtec FireFly electro-optical modules with a link speed of up to 25 Gbps. General production tests performed by the central Serenity group only validate the high-speed links via copper loopback cables. We present an optical acceptance test framework specifically designed for the calorimeter, providing comprehensive link and slow-control validation of installed FireFly modules under realistic operating conditions. This test combines loopback and board-to-board testing, extended bit error ratio measurements, and continuous module health monitoring within an automated workflow, delivering structured diagnostics and ensuring reliable large-scale system deployment.
Related
- Performance and quality testing of CBM RICH front-end electronics
- Toward testing antinucleonunicodex2013nucleus optical potentials with antineutron scattering lengths
- An optical cryostat for automated testing of silicon photomultipliers with vacuum-ultraviolet light
- E3J: An Efficient and Open-Source Backend for Euclidean Equivariant Operations on GPU and TPU
- A HIP-Compatible Accelerator Backend for Fourier-Bessel Particle-in-Cell Simulations on CPU/DCU Heterogeneous Clusters
BibTeX
@misc{qamesh2026optical,
title = {{Optical Acceptance Testing of Serenity-S1 Boards for the CMS HGCAL Phase-2 Backend Electronics}},
author = {A. Qamesh and P. D. Dauncey and H. A. Krause and P. Keskiner and S. Mallios and R. Shukla and N. Tarannum},
howpublished = {arXiv},
year = {2026},
month = nov,
doi = {10.48550/arxiv.2611.00418},
eprint = {2611.00418},
archivePrefix = {arXiv},
url = {https://arxiv.org/abs/2611.00418},
note = {CC BY 4.0},
}
RIS
TY - UNPB
TI - Optical Acceptance Testing of Serenity-S1 Boards for the CMS HGCAL Phase-2 Backend Electronics
AU - A. Qamesh
AU - P. D. Dauncey
AU - H. A. Krause
AU - P. Keskiner
AU - S. Mallios
AU - R. Shukla
AU - N. Tarannum
PY - 2026
DA - 2026/11/01
PB - arXiv
DO - 10.48550/arxiv.2611.00418
UR - https://arxiv.org/abs/2611.00418
AB - The CMS Phase-2 upgrade includes a new high-granularity calorimeter. The calorimeter electronics will include around 300 Serenity-S1 FPGA boards that use Samtec FireFly electro-optical modules with a link speed of up to 25 Gbps. General production tests performed by the central Serenity group only validate the high-speed links via copper loopback cables. We present an optical acceptance test framework specifically designed for the calorimeter, providing comprehensive link and slow-control validation of installed FireFly modules under realistic operating conditions. This test combines loopback and board-to-board testing, extended bit error ratio measurements, and continuous module health monitoring within an automated workflow, delivering structured diagnostics and ensuring reliable large-scale system deployment.
ER -