Skip to content
DraconiticResearch
Search Sources API
276,906 studies31 sourcesUpdated 7 min ago
Peer-reviewedCC BY 4.0Journal of Clinical Medicine

High-Frequency Ultrasound in Aesthetic Medicine: Technical Considerations and Clinical Applications

  1. 1Diagnostic Ultrasound Laboratory, Medical University of Warsaw, 03-242 Warsaw, Poland
  2. 2AST Ancona, Ospedale di Comunità Maria Montessori di Chiaravalle, 60126 Chiaravalle, Italy
  3. 3Life-Beauty-Private Company, ul. T. Kosciuszki 29, 05-825 Grodzisk Mazowiecki, Poland

Abstract

High frequency ultrasound (HFUS) is being used increasingly widely in aesthetic medicine, enabling real-time, noninvasive imaging of the skin, subcutaneous tissue, blood vessels, muscles, and previously injected materials. The aim of this article is to present the technical aspects, role, capabilities, and practical applications of ultrasound in aesthetic medicine, with particular emphasis on procedures performed on the face. The paper discusses equipment and imaging technique requirements, proposes a practical examination protocol, and presents the role and applications of HFUS before, during, and after a procedure. It also discusses the role of HFUS in monitoring the effects of performed procedures and in the diagnosis and treatment of complications. In pre-procedural assessment, HFUS enables imaging of tissue anatomy, mapping of blood vessels, determination of their course and depth, and identification and localization of previously injected materials, providing additional information useful for procedure planning. During the procedure, real-time imaging enables monitoring of the position of the needle or cannula relative to anatomical structures and the performance of selected procedures under ultrasound guidance. In the post-procedural period, HFUS can be used to assess and monitor the effects of procedures, including changes in tissue thickness and echogenicity, as well as the location and behavior of injected materials. It is also particularly important in the diagnosis of adverse events and complications, enabling the assessment of filler deposits, nodular and inflammatory changes, and vascular abnormalities and, in selected cases, the performance of targeted treatment under image guidance. The paper also discusses the most important limitations of HFUS related to equipment, operator dependence, the lack of full standardization, and the quality of the available scientific evidence. It also highlights prospects for further development, including improvements in imaging technology, advances in ultrasound-guided procedures, quantitative image analysis, and the potential application of artificial intelligence. HFUS can serve as an important tool supporting clinical decision-making at all stages of aesthetic medicine practice.

Related

  1. Retrieval-augmented generation in medicine: A scoping review of technical implementations, clinical applications, and ethical considerations
    Rui Yang, Matthew Yu Heng Wong, Huitao Li +13
    Cell Reports MedicinePeer-reviewedCC BY-NC-ND28 citedEpidemiology & public healthOpenAlex
  2. Percutaneous Cryoablation in Bone Tumors: Current Applications, Technical Considerations, Clinical Outcomes, and Future Perspectives
    Emrah Karatay, Cagri Saylan, Emre Karacay +2
    CureusPeer-reviewedCC BYFull textMedical imaging & radiologyOncologyEurope PMCPMC
  3. Cryoablation in Thyroid Nodules: Current Evidence, Technical Considerations, and Clinical Applications.
    Emrah Karatay, Alim Akbarov, Aykhan Abbasov +1
    CureusPeer-reviewedCC BYFull textMedical imaging & radiologyEurope PMCPMC
  4. Advancements in Noncontrast Ultrasound Imaging for Low-Velocity Flow: A Technical Review and Clinical Applications in Vascular Medicine
    Rayan Seddiki, Tristan Mirault, Jonas Sitruk +5
    Ultrasound in Medicine and BiologyPeer-reviewedCC BYFull text22 citedSystems & synthetic biologyMedical imaging & radiologyHAL
  5. Ergonomics in Facial Ultrasound: Potential Influence on Image Quality, Reproducibility, and Ultrasound-Guided Aesthetic Procedures
    Andrea Maria Scarpa, Orlando Catalano, Ximena Wortsman +2
    Diagnostics (Basel, Switzerland)Peer-reviewedCC BYFull textGeneral medicineEurope PMC
BibTeX
@article{mlosek2026highfrequency,
  title = {{High-Frequency Ultrasound in Aesthetic Medicine: Technical Considerations and Clinical Applications}},
  author = {Robert Krzysztof Mlosek and Corrado Tagliati and Sylwia Patrycja Malinowska},
  journal = {Journal of Clinical Medicine},
  year = {2026},
  month = nov,
  doi = {10.3390/jcm15228782},
  url = {https://www.mdpi.com/2077-0383/15/22/8782},
  note = {CC BY 4.0},
}
RIS
TY  - JOUR
TI  - High-Frequency Ultrasound in Aesthetic Medicine: Technical Considerations and Clinical Applications
AU  - Robert Krzysztof Mlosek
AU  - Corrado Tagliati
AU  - Sylwia Patrycja Malinowska
PY  - 2026
DA  - 2026/11/01
JO  - Journal of Clinical Medicine
DO  - 10.3390/jcm15228782
UR  - https://www.mdpi.com/2077-0383/15/22/8782
AB  - High frequency ultrasound (HFUS) is being used increasingly widely in aesthetic medicine, enabling real-time, noninvasive imaging of the skin, subcutaneous tissue, blood vessels, muscles, and previously injected materials. The aim of this article is to present the technical aspects, role, capabilities, and practical applications of ultrasound in aesthetic medicine, with particular emphasis on procedures performed on the face. The paper discusses equipment and imaging technique requirements, proposes a practical examination protocol, and presents the role and applications of HFUS before, during, and after a procedure. It also discusses the role of HFUS in monitoring the effects of performed procedures and in the diagnosis and treatment of complications. In pre-procedural assessment, HFUS enables imaging of tissue anatomy, mapping of blood vessels, determination of their course and depth, and identification and localization of previously injected materials, providing additional information useful for procedure planning. During the procedure, real-time imaging enables monitoring of the position of the needle or cannula relative to anatomical structures and the performance of selected procedures under ultrasound guidance. In the post-procedural period, HFUS can be used to assess and monitor the effects of procedures, including changes in tissue thickness and echogenicity, as well as the location and behavior of injected materials. It is also particularly important in the diagnosis of adverse events and complications, enabling the assessment of filler deposits, nodular and inflammatory changes, and vascular abnormalities and, in selected cases, the performance of targeted treatment under image guidance. The paper also discusses the most important limitations of HFUS related to equipment, operator dependence, the lack of full standardization, and the quality of the available scientific evidence. It also highlights prospects for further development, including improvements in imaging technology, advances in ultrasound-guided procedures, quantitative image analysis, and the potential application of artificial intelligence. HFUS can serve as an important tool supporting clinical decision-making at all stages of aesthetic medicine practice.
SN  - 2077-0383
ER  -