Skip to content
DraconiticResearch
Search Sources API
190,851 studies31 sourcesUpdated 45 min ago
PreprintCC BYChemRxiv

Actinometric Methods to Assess Fluence for Ultraviolet Water Disinfection: A Systematic Review

  1. 1Mechanical Engineering
  2. 2Pennsylvania State University
  3. 3Institute of Energy and the Environment

Abstract

Ultraviolet (UV) disinfection is a chemical-free treatment technology that is effective at inactivating a broad range of waterborne microbial pathogens. Ensuring safe and reliable disinfection performance for these systems requires accurate determination of the UV fluence delivered within the water treatment environment. Conventional fluence determination approaches, including biodosimetry and radiometry, exhibit limitations related to pathogen availability, spatial averaging, directional sensitivity, and applicability in enclosed systems. Chemical actinometry offers an alternative approach based on photochemical transformations that integrate the effective UV fluence within a system. However, its application in UV disinfection research remains fragmented, with limited guidance on selecting and implementing appropriate actinometric methods under different conditions. This systematic review aims to inform the application of chemical actinometers to assess the UV fluence for water disinfection systems. The review covers the application of commonly used actinometers, including potassium iodide/iodate, potassium ferrioxalate, uridine, and hydrogen peroxide, across a range of UV sources. The mathematical framework for deriving germicidal UV fluence from actinometric measurements is synthesized, with emphasis on wavelength-dependent behavior and experimental considerations. In addition, key limitations of chemical actinometry, including challenges in translating bench-scale methods to flow-through systems, are evaluated. These findings highlight current knowledge gaps and provide direction for improving the use of chemical actinometry to determine fluence in UV water disinfection systems.

Related

  1. Effectiveness of ultraviolet–C robots in isolation room disinfection: Impact of dose, distance, and direct exposure on environmental surface decontamination
    Ying-Chun Chen, Wei-Ling Liao, Su-Chiu Wang +1
    PLOS OnePeer-reviewedCC BY 4.0MicrobiologyEpidemiology & public healthPLOS
  2. Low-fluence 730-nm picosecond titanium sapphire laser for pediatric facial café-au-lait macules: a non-crusting treatment approach
    Hanyu Lee, Pinru Wu, Qingqing Cen +3
    Scientific ReportsPeer-reviewedCC BY-NC-ND 4.0Full textGeneral medicineCrossref
  3. Stereopsis and Outer Retinal Structure After Reduced-Fluence Photodynamic Therapy for Central Serous Chorioretinopathy: A 12-Month Study
    Maya Kishimoto-Kishi, Akiko Miki, Amiko Matsuyama +3
    Ophthalmology and TherapyPeer-reviewedCC BY-NCFull textGeneral medicineDOAJ
  4. Fluence-Dependent Effects of 940-nm Photobiomodulation on the Proliferation and Osteoblastic Differentiation of Human Periodontal Ligament Stem Cells.
    Jovan Marković, Milan Marković, Jelena Đokić +5
    Dentistry journalPeer-reviewedCC BYFull textMedical imaging & radiologyEurope PMC
  5. Implementation strategies, outcomes and determinants of integrated care for cardiometabolic conditions and mental, neurological and substance use disorders: protocol for a mixed-methods systematic review
    Emma Jeltje Blinker, Gordon Kwasi Ampomah Amoh, Samuel Ankamah +6
    BMJ OpenPeer-reviewedCC BY 4.0Full textGeneral medicineCrossrefEurope PMC
BibTeX
@misc{seyedin2026actinometric,
  title = {{Actinometric Methods to Assess Fluence for Ultraviolet Water Disinfection: A Systematic Review}},
  author = {Mahla Seyedin and Margaret M. Busse},
  howpublished = {ChemRxiv},
  year = {2026},
  month = sep,
  doi = {10.26434/chemrxiv.15008373/v1},
  url = {https://chemrxiv.org/doi/full/10.26434/chemrxiv.15008373/v1},
  note = {CC BY},
}
RIS
TY  - UNPB
TI  - Actinometric Methods to Assess Fluence for Ultraviolet Water Disinfection: A Systematic Review
AU  - Mahla Seyedin
AU  - Margaret M. Busse
PY  - 2026
DA  - 2026/09/06
PB  - ChemRxiv
DO  - 10.26434/chemrxiv.15008373/v1
UR  - https://chemrxiv.org/doi/full/10.26434/chemrxiv.15008373/v1
AB  - Ultraviolet (UV) disinfection is a chemical-free treatment technology that is effective at inactivating a broad range of waterborne microbial pathogens. Ensuring safe and reliable disinfection performance for these systems requires accurate determination of the UV fluence delivered within the water treatment environment. Conventional fluence determination approaches, including biodosimetry and radiometry, exhibit limitations related to pathogen availability, spatial averaging, directional sensitivity, and applicability in enclosed systems. Chemical actinometry offers an alternative approach based on photochemical transformations that integrate the effective UV fluence within a system. However, its application in UV disinfection research remains fragmented, with limited guidance on selecting and implementing appropriate actinometric methods under different conditions. This systematic review aims to inform the application of chemical actinometers to assess the UV fluence for water disinfection systems. The review covers the application of commonly used actinometers, including potassium iodide/iodate, potassium ferrioxalate, uridine, and hydrogen peroxide, across a range of UV sources. The mathematical framework for deriving germicidal UV fluence from actinometric measurements is synthesized, with emphasis on wavelength-dependent behavior and experimental considerations. In addition, key limitations of chemical actinometry, including challenges in translating bench-scale methods to flow-through systems, are evaluated. These findings highlight current knowledge gaps and provide direction for improving the use of chemical actinometry to determine fluence in UV water disinfection systems.
ER  -