Hydration‐Driven Self‐Strengthening Silk Fibroin Ionic Elastomer for Electro‐Immunomodulatory Achilles Tendon Repair
5 affiliations
- 1Department of Orthopedic Surgery, Zhongshan Hospital Fudan University Shanghai China
- 2Department of Orthopaedics Shanghai Xuhui Central Hospital Shanghai China
- 3State Key Laboratory of Molecular Engineering of Polymers Department of Macromolecular Science Fudan University Shanghai China
- 4Xiamen Osteoporosis Specialized Prevention and Treatment Center Xiamen China
- 5Department of Orthopaedic Surgery Zhongshan Hospital (Xiamen) Fudan University Xiamen China
Abstract
Achilles tendon repair remains limited by fibrotic healing and implants' inability to coordinate mechanical support, ionic signaling, electrical cues, and immune remodeling in wet load‐bearing environments. We report a bioinspired self‐strengthening silk fibroin ionic elastomer (SFIE) as an electro‐immunomodulatory artificial Achilles tendon. Lithium chloride is integrated into regenerated silk fibroin to create a hydration‐responsive protein‐ion network. Upon water uptake, LiCl‐associated hydration may facilitate chain mobility and the reorganization of hydrophobic silk domains into β‐sheet nanocrystals, enhancing tensile strength and modulus while preserving extensibility, fatigue resistance, and ionic conductivity. SFIE sustains Li+ release within a bioactive window that supports bone marrow mesenchymal stem cell (BMSC) viability and tenogenic activity. Mechanistically, SFIE‐derived Li+ is associated with altered BMSC paracrine signaling, including reduced arachidonic acid secretion, which may modulate macrophage inflammatory responses. These effects are associated with changes in cPLA2/DUSP3/p38‐related signaling. With electrical stimulation, SFIE increases intracellular Ca2 + levels and is associated with changes in CaM/CREB/NR4A1/LIF‐related signaling and reduced CXCL10 secretion, potentially contributing to altered macrophage recruitment. In a rat Achilles tendon defect model, SFIE plus electrical stimulation improves gait recovery, tendon continuity, collagen alignment, tendon‐marker expression, and local immune remodeling. This work establishes a self‐strengthening ionic protein elastomer for functional tendon repair.
Related
- Engineering Silk Fibroin‐Based Biomaterials for Neural Repair
- Direct Integration of Electrospun Polycaprolactone Fibers with Polydimethylsiloxane: Influence of Elastomer Formulation on Fiber–Elastomer Adhesion
- Heparin- and Selenocystamine-Functionalized Silk Fibroin Hydrogel for Anticoagulation and Catalytic Nitric Oxide Generation
- Development of a Photocrosslinked Methacrylated Silk Fibroin Hydrogel Incorporating Hesperidin-Loaded Liposomes for Wound Dressing Applications.
- Titin‐Mimetic Phase Separation Enables a High‐Performance Dielectric Elastomer for Artificial Muscles
BibTeX
@article{zeng2026hydrationdriven,
title = {{Hydration‐Driven Self‐Strengthening Silk Fibroin Ionic Elastomer for Electro‐Immunomodulatory Achilles Tendon Repair}},
author = {Heng‐Jie Zeng and Guang‐Cheng Yuan and Fu‐Lai Zhu and Chi‐Yuan Chen and Jian Dong and Haikang Cai and Shengjie Ling and Li‐Bo Jiang},
journal = {Advanced Science},
year = {2026},
month = nov,
doi = {10.1002/advs.78835},
url = {https://doi.org/10.1002/advs.78835},
note = {CC BY 4.0},
}
RIS
TY - JOUR
TI - Hydration‐Driven Self‐Strengthening Silk Fibroin Ionic Elastomer for Electro‐Immunomodulatory Achilles Tendon Repair
AU - Heng‐Jie Zeng
AU - Guang‐Cheng Yuan
AU - Fu‐Lai Zhu
AU - Chi‐Yuan Chen
AU - Jian Dong
AU - Haikang Cai
AU - Shengjie Ling
AU - Li‐Bo Jiang
PY - 2026
DA - 2026/11/22
JO - Advanced Science
DO - 10.1002/advs.78835
UR - https://doi.org/10.1002/advs.78835
AB - Achilles tendon repair remains limited by fibrotic healing and implants' inability to coordinate mechanical support, ionic signaling, electrical cues, and immune remodeling in wet load‐bearing environments. We report a bioinspired self‐strengthening silk fibroin ionic elastomer (SFIE) as an electro‐immunomodulatory artificial Achilles tendon. Lithium chloride is integrated into regenerated silk fibroin to create a hydration‐responsive protein‐ion network. Upon water uptake, LiCl‐associated hydration may facilitate chain mobility and the reorganization of hydrophobic silk domains into β‐sheet nanocrystals, enhancing tensile strength and modulus while preserving extensibility, fatigue resistance, and ionic conductivity. SFIE sustains Li+ release within a bioactive window that supports bone marrow mesenchymal stem cell (BMSC) viability and tenogenic activity. Mechanistically, SFIE‐derived Li+ is associated with altered BMSC paracrine signaling, including reduced arachidonic acid secretion, which may modulate macrophage inflammatory responses. These effects are associated with changes in cPLA2/DUSP3/p38‐related signaling. With electrical stimulation, SFIE increases intracellular Ca2 + levels and is associated with changes in CaM/CREB/NR4A1/LIF‐related signaling and reduced CXCL10 secretion, potentially contributing to altered macrophage recruitment. In a rat Achilles tendon defect model, SFIE plus electrical stimulation improves gait recovery, tendon continuity, collagen alignment, tendon‐marker expression, and local immune remodeling. This work establishes a self‐strengthening ionic protein elastomer for functional tendon repair.
SN - 2198-3844