Skip to content
DraconiticResearch
Search Sources API
194,161 studies31 sourcesUpdated 54 min ago
Peer-reviewedCC BYJMIR formative research

Technical Feasibility of a Multimodal Electro-Optical and Infrared Imaging Pipeline for Postoperative Wound Assessment After Total Knee Arthroplasty: Formative Evaluation Study.

  1. 1Truss Health, Inc., Las Vegas, NV, United States.
  2. 2Sunshine Bone and Joint Institute, Krishna Institute of Medical Sciences, Begumpet, Telangana, India.

Abstract

Background

Early detection and monitoring of wound-related complications after total knee arthroplasty (TKA) are critical to optimize outcomes and preserve implants. Conventional postoperative monitoring relies on in-person assessment and patient-reported symptoms, which may delay recognition. Noncontact imaging acquired in the clinic or at home offers a potential route to earlier and more consistent assessment.Objective

This study aimed to evaluate the technical feasibility and performance of a multimodal AI system integrating electro-optical (EO) and infrared imaging for postoperative wound assessment following TKA and to explore clinical factors associated with early complications.Methods

We conducted a single-center prospective cohort study of 749 patients undergoing primary TKA. Patients underwent standardized multimodal data collection at scheduled postoperative visits. EO-based models localized surgical landmarks and segmented complication-oriented tissue states; a fine-tuned vision-language model provided protocol verification and contextual visual reasoning. EO landmarks mapped to thermal space via deterministic alignment, followed by infrared region-of-interest segmentation and thermal classification. Each module was evaluated on a defined held-out set. The thermal classifier was assessed out-of-fold under 5-fold cross-validation with folds grouped by patient, in knees imaged on postoperative day 14 or later. Discrimination for clinician-adjudicated infection-related complications served as the primary outcome. Comorbidities and baseline laboratory values were explored for associations with complications.Results

Among 749 patients, 26 (3.5%) had a clinician-adjudicated infection-related complication. On held-out evaluation, the EO landmark detector reached a sensitivity of 0.967 (95% CI 0.954-0.979) and positive predictive value of 0.955 (95% CI 0.940-0.970), and the wound-tissue segmentation model reached a sensitivity of 0.845 (95% CI 0.833-0.857) and positive predictive value of 0.759 (95% CI 0.744-0.772). Infrared region-of-interest extraction isolated the surgical field with a mean intersection-over-union of 0.985 (SD 0.008; 95% CI 0.984-0.986) across 178 held-out patients. The trained thermal classifier discriminated infected scans with an area under the receiver operating characteristic curve (AUROC) of 0.978 (95% CI 0.959-0.992) in out-of-fold, patient-grouped cross-validation. At a representative operating point, sensitivity was 0.808 (95% CI 0.65-0.92), specificity 0.974 (95% CI 0.96-0.99), positive predictive value 0.618 (95% CI 0.49-0.78), and negative predictive value 0.990 (95% CI 0.98-1.00). Exploratory analyses showed nominal associations of chronic kidney disease and diabetes mellitus with postoperative complications that did not remain significant after multiplicity correction.Conclusions

In this formative study, a multimodal EO and infrared imaging pipeline demonstrated technical feasibility for postoperative wound assessment following TKA, providing noncontact discrimination of infection-related complications that compared favorably with established adjuncts. This work provides proof-of-concept for multimodal imaging-based assessment and defines the technical requirements for the prospective, multicenter external validation needed to establish clinical utility.

Related

  1. The degeneration of uncovertebral joints on CT assessment and its association with postoperative heterotopic ossification in one- or two-level artificial cervical arthroplasty.
    Yi Yang, Weiyang Zhong
    Frontiers in surgeryPeer-reviewedCC BYFull textSurgery & anaesthesiaEurope PMC
  2. Is Routine Patellar Resurfacing During Primary Total Knee Arthroplasty Associated With Increased Rates of Postoperative Peripatellar Injury?
    John M. Dundon, Skylar Lewis, Nicholas Brown +2
    Arthroplasty todayPeer-reviewedCC BY-NC-NDFull textSurgery & anaesthesiaEurope PMC
  3. Intrinsic capacity patterns and their association with early postoperative functional outcomes in older adults undergoing total knee arthroplasty
    Ruixin Zhang, Jie Chen, Xueer Chen +2
    Scientific ReportsPeer-reviewedCC BYFull textSurgery & anaesthesiaDOAJ
  4. PROSPECT guideline for total hip arthroplasty: updated systematic review and procedure‐specific postoperative pain management recommendations
    Michele Carella, Dario Bugada, Marc van de Velde +5
    AnaesthesiaPeer-reviewedCC BY-NC 4.0Full text1 citedSurgery & anaesthesiaHAL
  5. Postoperative Antibiotic Duration and Treatment Failure After Aseptic Revision Arthroplasty With a Single Unexpected Positive Culture: A Retrospective Cohort Study.
    Hao-Chang Hsieh, Feng-Chih Kuo, Allen Herng Shouh Hsu +3
    Orthopaedic surgeryPeer-reviewedCC BYFull textSurgery & anaesthesiaEurope PMC
BibTeX
@article{ranade2026technical,
  title = {{Technical Feasibility of a Multimodal Electro-Optical and Infrared Imaging Pipeline for Postoperative Wound Assessment After Total Knee Arthroplasty: Formative Evaluation Study.}},
  author = {Tej S Ranade and Emily Hu and Kadambari Beelwar and Sandeep Boddeda and Praharsha Mulpur and Adarsh Annapareddy and A V Gurava Reddy},
  journal = {JMIR formative research},
  year = {2026},
  month = oct,
  doi = {10.2196/99244},
  url = {https://europepmc.org/article/MED/42849894},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - Technical Feasibility of a Multimodal Electro-Optical and Infrared Imaging Pipeline for Postoperative Wound Assessment After Total Knee Arthroplasty: Formative Evaluation Study.
AU  - Tej S Ranade
AU  - Emily Hu
AU  - Kadambari Beelwar
AU  - Sandeep Boddeda
AU  - Praharsha Mulpur
AU  - Adarsh Annapareddy
AU  - A V Gurava Reddy
PY  - 2026
DA  - 2026/10/08
JO  - JMIR formative research
DO  - 10.2196/99244
UR  - https://europepmc.org/article/MED/42849894
AB  - Background  Early detection and monitoring of wound-related complications after total knee arthroplasty (TKA) are critical to optimize outcomes and preserve implants. Conventional postoperative monitoring relies on in-person assessment and patient-reported symptoms, which may delay recognition. Noncontact imaging acquired in the clinic or at home offers a potential route to earlier and more consistent assessment.Objective  This study aimed to evaluate the technical feasibility and performance of a multimodal AI system integrating electro-optical (EO) and infrared imaging for postoperative wound assessment following TKA and to explore clinical factors associated with early complications.Methods  We conducted a single-center prospective cohort study of 749 patients undergoing primary TKA. Patients underwent standardized multimodal data collection at scheduled postoperative visits. EO-based models localized surgical landmarks and segmented complication-oriented tissue states; a fine-tuned vision-language model provided protocol verification and contextual visual reasoning. EO landmarks mapped to thermal space via deterministic alignment, followed by infrared region-of-interest segmentation and thermal classification. Each module was evaluated on a defined held-out set. The thermal classifier was assessed out-of-fold under 5-fold cross-validation with folds grouped by patient, in knees imaged on postoperative day 14 or later. Discrimination for clinician-adjudicated infection-related complications served as the primary outcome. Comorbidities and baseline laboratory values were explored for associations with complications.Results  Among 749 patients, 26 (3.5%) had a clinician-adjudicated infection-related complication. On held-out evaluation, the EO landmark detector reached a sensitivity of 0.967 (95% CI 0.954-0.979) and positive predictive value of 0.955 (95% CI 0.940-0.970), and the wound-tissue segmentation model reached a sensitivity of 0.845 (95% CI 0.833-0.857) and positive predictive value of 0.759 (95% CI 0.744-0.772). Infrared region-of-interest extraction isolated the surgical field with a mean intersection-over-union of 0.985 (SD 0.008; 95% CI 0.984-0.986) across 178 held-out patients. The trained thermal classifier discriminated infected scans with an area under the receiver operating characteristic curve (AUROC) of 0.978 (95% CI 0.959-0.992) in out-of-fold, patient-grouped cross-validation. At a representative operating point, sensitivity was 0.808 (95% CI 0.65-0.92), specificity 0.974 (95% CI 0.96-0.99), positive predictive value 0.618 (95% CI 0.49-0.78), and negative predictive value 0.990 (95% CI 0.98-1.00). Exploratory analyses showed nominal associations of chronic kidney disease and diabetes mellitus with postoperative complications that did not remain significant after multiplicity correction.Conclusions  In this formative study, a multimodal EO and infrared imaging pipeline demonstrated technical feasibility for postoperative wound assessment following TKA, providing noncontact discrimination of infection-related complications that compared favorably with established adjuncts. This work provides proof-of-concept for multimodal imaging-based assessment and defines the technical requirements for the prospective, multicenter external validation needed to establish clinical utility.
SN  - 2561-326X
ER  -