Skip to content
DraconiticResearch
Search Sources API
186,125 studies31 sourcesUpdated 49 min ago
PreprintCC BY 4.0arXiv

Role of self-coherence in single-electron phase contrast imaging

Abstract

The extension of coherent lattice contrast into the energy loss region in high-resolution transmission electron microscopy (HRTEM) is described by a pulse-like electron-sample interaction in the energy/time uncertainty limit. It generates a wave packet by electron self-interference in any coherent-inelastic scattering event with energy loss. The width of this wave packet is characterized by a self-coherence length ls(ΔE) that is predictable because an intrinsic decoherence phase around one radian is set by the expectation value for phase fluctuations. In this case the visibility of interference contrast from a crystalline sample with lattice parameter a is limited by a Rayleigh-like transfer factor P(ls, a) in the self-coherently illuminated sample area. The model is verified by energy-filtered HRTEM images of hexagonal BN and identifies energy-loss-induced phase noise as a single-electron visibility limit distinct from resolution limitations caused by ensemble-coherence or counting-statistical noise.

Related

  1. Multi-Angle Beam Scanning Transmission Electron Microscopy for Diffraction-Contrast-Free Magnetic Imaging
    Akira Yasuhara, Zentaro Akase, Takumi Sannomiya
    arXivPreprintarXiv licenceFull textApplied physics & instrumentationarXiv
  2. Investigating twin boundary-dislocation interaction in MgY using quasi in-situ nanoindentation and electron channeling contrast imaging
    Fatim Zahra Mouhib, Hexin Wang, Julien Guénolé +5
    Journal of Magnesium and AlloysPeer-reviewedCC BY-NC-ND 4.0Full text1 citedCondensed matterHAL
  3. Effects of X-ray absorption on grating-based and propagation-based phase-contrast imaging
    Jun Yang, Jun Qi, Hui Fang Zhang +1
    Optics ExpressPeer-reviewedLicence not statedApplied physics & instrumentationCrossref
  4. Automated Dislocation Detection in Electron Channelling Contrast Imaging: A Comparative Study of Rule-Based, Neural Network, and Deep Learning Approaches
    A. Holmes, C. Trager-Cowan, J. Bruckbauer +1
    arXivPreprintarXiv licenceFull textCondensed matterarXiv
  5. High resolution X-ray phase contrast imaging for non-destructive testing of composite materials (2022)
    Georges Giakoumakis, Adrien Stolidi, Jérôme Primot
    ReJNDTPeer-reviewedCC BYMaterials & polymersApplied physics & instrumentationHAL
BibTeX
@misc{kisielowski2026role,
  title = {{Role of self-coherence in single-electron phase contrast imaging}},
  author = {Christian Kisielowski and Petra Specht and Joerg Jinschek and Stig Helveg},
  howpublished = {arXiv},
  year = {2026},
  month = aug,
  doi = {10.48550/arxiv.2608.30833},
  eprint = {2608.30833},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2608.30833},
  note = {CC BY 4.0},
}
RIS
TY  - UNPB
TI  - Role of self-coherence in single-electron phase contrast imaging
AU  - Christian Kisielowski
AU  - Petra Specht
AU  - Joerg Jinschek
AU  - Stig Helveg
PY  - 2026
DA  - 2026/08/31
PB  - arXiv
DO  - 10.48550/arxiv.2608.30833
UR  - https://arxiv.org/abs/2608.30833
AB  - The extension of coherent lattice contrast into the energy loss region in high-resolution transmission electron microscopy (HRTEM) is described by a pulse-like electron-sample interaction in the energy/time uncertainty limit. It generates a wave packet by electron self-interference in any coherent-inelastic scattering event with energy loss. The width of this wave packet is characterized by a self-coherence length ls(ΔE) that is predictable because an intrinsic decoherence phase around one radian is set by the expectation value for phase fluctuations. In this case the visibility of interference contrast from a crystalline sample with lattice parameter a is limited by a Rayleigh-like transfer factor P(ls, a) in the self-coherently illuminated sample area. The model is verified by energy-filtered HRTEM images of hexagonal BN and identifies energy-loss-induced phase noise as a single-electron visibility limit distinct from resolution limitations caused by ensemble-coherence or counting-statistical noise.
ER  -