Patronus: patient-specific training setup for aortic aneurysm repair
- 1Computer Science Department, TU Darmstadt, Fraunhoferstr. 5, Darmstadt, 64293 Hessen Germany
- 2Klinik und Poliklinik für Gefäßchirurgie– Vaskuläre und endovaskuläre Chirurgie, Uniklinik Köln, Kerpener Str. 62, Cologne, 50937 Nordrhein-Westfalen Germany
Abstract
Purpose:: Surgical training for Aortic Repair (EVAR) on simulators holds the potential to reduce radiation of the X-ray-guided procedure. Precision and realism of training simulators increases significantly with the use of patient-specific phantoms. However, radiation-free setups utilizing 3D-printed anatomies lack realistic imaging.
Method:: We propose PATRONUS, a hardware and software prototype for patient-specific, radiation-free surgical training for EVAR. 3D printed, transparent phantoms are imaged inside a black box which is accessed from the outside. Pseudo X-rays are generated through reconstructed radiographs, which are enhanced by virtual catheters and contrast agent.
Results:: Our prototype demonstrates a complete pipeline including a 3D printing workflow, phantom preparation, online registration of phantoms to the patient CT and pseudo X-ray generation. We report an average registration error (RMSE) of the scene inside the simulator to the digital twin of \documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}9.30 mm\end{document}9.30mm. The entire simulator pipeline takes \documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}1.059 s\end{document}1.059s to execute per image.
Conclusion:: State-of-the-art techniques for scene understanding and 3D printing enable the transition from simulated interventions on 3D printed vascular phantoms under cameras to a digital twin representation in the CT regime. The PATRONUS simulator prototype thus provides a foundation for radiation-free, realistic endovascular surgical training with patient-specific phantoms.
Related
- The Need for Device-Specific Training Before Handheld Ultrasound Use: Agreement and Repeatability of Simulated Aortic Aneurysm Diameter Measurements by Senior Sonography Students on a Familiar Conventional and an Unfamiliar Handheld System
- Fenestrated-branched endovascular repair of a complex abdominal aortic aneurysm in a patient with a pelvic kidney and left ventricular assist device
- Fenestrated-branched endovascular repair of a complex abdominal aortic aneurysm in a patient with a pelvic kidney and left ventricular assist device
- Successful Repair of Giant Aortic Aneurysm With Severe Aortic Regurgitation in Fontan Patient
- Patient-specific finite element modeling of image-derived shell morphoelastic growth: A general framework and application to stented aortic dissection
BibTeX
@article{krumb2026patronus,
title = {{Patronus: patient-specific training setup for aortic aneurysm repair}},
author = {Henry John Krumb and Bernhard Dorweiler and Anirban Mukhopadhyay},
journal = {International Journal of Computer Assisted Radiology and Surgery},
year = {2026},
month = jun,
doi = {10.1007/s11548-026-03715-y},
url = {https://doi.org/10.1007/s11548-026-03715-y},
note = {CC BY 4.0},
}
RIS
TY - JOUR
TI - Patronus: patient-specific training setup for aortic aneurysm repair
AU - Henry John Krumb
AU - Bernhard Dorweiler
AU - Anirban Mukhopadhyay
PY - 2026
DA - 2026/06/03
JO - International Journal of Computer Assisted Radiology and Surgery
DO - 10.1007/s11548-026-03715-y
UR - https://doi.org/10.1007/s11548-026-03715-y
AB - Purpose:: Surgical training for Aortic Repair (EVAR) on simulators holds the potential to reduce radiation of the X-ray-guided procedure. Precision and realism of training simulators increases significantly with the use of patient-specific phantoms. However, radiation-free setups utilizing 3D-printed anatomies lack realistic imaging. Method:: We propose PATRONUS, a hardware and software prototype for patient-specific, radiation-free surgical training for EVAR. 3D printed, transparent phantoms are imaged inside a black box which is accessed from the outside. Pseudo X-rays are generated through reconstructed radiographs, which are enhanced by virtual catheters and contrast agent. Results:: Our prototype demonstrates a complete pipeline including a 3D printing workflow, phantom preparation, online registration of phantoms to the patient CT and pseudo X-ray generation. We report an average registration error (RMSE) of the scene inside the simulator to the digital twin of \documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}9.30 mm\end{document}9.30mm. The entire simulator pipeline takes \documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}1.059 s\end{document}1.059s to execute per image. Conclusion:: State-of-the-art techniques for scene understanding and 3D printing enable the transition from simulated interventions on 3D printed vascular phantoms under cameras to a digital twin representation in the CT regime. The PATRONUS simulator prototype thus provides a foundation for radiation-free, realistic endovascular surgical training with patient-specific phantoms.
SN - 1861-6410
SN - 1861-6429
ER -