Skip to content
DraconiticResearch
Search Sources API
276,906 studies31 sourcesUpdated 30 min ago
PreprintCC BY-NC-NDbioRxiv

A near-infrared fluorescent genetically encoded calcium ion biosensor with a direct response

1 more authors
  1. 1The University of Tokyo

Abstract

Near-infrared genetically encoded calcium ion (Ca2+) indicators (NIR GECIs) enable Ca2+ imaging at longer wavelengths than green or red fluorescent GECIs, providing reduced autofluorescence and phototoxicity, and improved compatibility with deep-tissue and multiplexed imaging applications. We have previously reported biliverdin (BV)-binding phytochrome-based NIR GECIs such as NIR-GECO2G that exhibit inverse fluorescence responses. Although inverse response GECIs can effectively report Ca2+ dynamics, their high baseline fluorescence in the resting apo state causes faster photobleaching and substantial out-of-focus background fluorescence, complicating signal interpretation. Here, using the inverse response NIR-GECO2G as the starting scaffold, we developed a direct response Ca2+ indicator, designated dNIR-GECO1.0, through iterative rounds of protein engineering and screening. dNIR-GECO1.0 exhibited greater molecular brightness than NIR-GECO2G, robust fluorescence in mammalian cells without exogenous BV supplementation, and a high dynamic range for reporting Ca2+ changes. A detailed mechanistic investigation identified the key mutations within the Ca2+ binding domain that were necessary to convert the inverse response indicator into a direct response indicator. Resonance Raman spectroscopic analysis provided insight into the specific changes in the BV chromophore resulting from the Ca2+-dependent conformational change.

Related

  1. mechanoLight: A genetically encoded fluorescent biosensor for visualizing 5-HT2AR mechanotransduction in live cells
    In-Yeop Baek, Hyunbin Kim, Duwan Kwon +2
    Proceedings of the National Academy of Sciences of the United States of AmericaPeer-reviewedCC BY-NC-ND 4.0Full textMolecular biology & gene regulationPMC
  2. Genetically encoded dinitrobenzyl photostabilizer for enhancing the photostability of fluorescent proteins
    Guihua Li, Xia Wang, Jiben Xue +1
    RSC Chemical BiologyPeer-reviewedCC BY-NC 3.0Full textBiophysicsPMC
  3. Near-infrared light-controlled catalytic hairpin assembly fluorescent biosensor for the sensitive and specific detection of fibroblast activation protein
    Jiayi Wu, Xingchun Zheng, Jinhua Huang +1
    Nanoscale AdvancesPeer-reviewedCC BY-NC 3.0Full textMolecular biology & gene regulationPMC
  4. Mapping the Nonhistone Interactome of the TRIM24 Bromodomain Using Genetically Encoded Complementary Photocrosslinkers
    I. Bardhan, S. Chakraborty, N. S. Ponnaganti +1
    bioRxivPreprintAll rights reservedFull textMolecular biology & gene regulationbioRxiv
  5. Fluorescent Biosensor Based on Hairpin DNA Probe with Endonuclease Cleavage Inhibition for Rapid Detection of Dam Methyltransferase Activity.
    Fangfang He, Zehui Bai, Pansong Zhang
    BiosensorsPeer-reviewedCC BYFull textMolecular biology & gene regulationEurope PMC
BibTeX
@misc{musa2026nearinfrared,
  title = {{A near-infrared fluorescent genetically encoded calcium ion biosensor with a direct response}},
  author = {M. Musa and R. Campbell and T. Terai and Y. Qian and M. Mizuno and Y. Nasu and K. Tamagawa and R. Udo and S. Imai and K. Sawada and O. Nureki and R. Hashizume and T. Kobayashi},
  howpublished = {bioRxiv},
  year = {2026},
  month = nov,
  doi = {10.64898/2026.11.15.766740},
  url = {https://www.biorxiv.org/content/10.64898/2026.11.15.766740v1},
  note = {CC BY-NC-ND},
}
RIS
TY  - UNPB
TI  - A near-infrared fluorescent genetically encoded calcium ion biosensor with a direct response
AU  - M. Musa
AU  - R. Campbell
AU  - T. Terai
AU  - Y. Qian
AU  - M. Mizuno
AU  - Y. Nasu
AU  - K. Tamagawa
AU  - R. Udo
AU  - S. Imai
AU  - K. Sawada
AU  - O. Nureki
AU  - R. Hashizume
AU  - T. Kobayashi
PY  - 2026
DA  - 2026/11/15
PB  - bioRxiv
DO  - 10.64898/2026.11.15.766740
UR  - https://www.biorxiv.org/content/10.64898/2026.11.15.766740v1
AB  - Near-infrared genetically encoded calcium ion (Ca2+) indicators (NIR GECIs) enable Ca2+ imaging at longer wavelengths than green or red fluorescent GECIs, providing reduced autofluorescence and phototoxicity, and improved compatibility with deep-tissue and multiplexed imaging applications. We have previously reported biliverdin (BV)-binding phytochrome-based NIR GECIs such as NIR-GECO2G that exhibit inverse fluorescence responses. Although inverse response GECIs can effectively report Ca2+ dynamics, their high baseline fluorescence in the resting apo state causes faster photobleaching and substantial out-of-focus background fluorescence, complicating signal interpretation. Here, using the inverse response NIR-GECO2G as the starting scaffold, we developed a direct response Ca2+ indicator, designated dNIR-GECO1.0, through iterative rounds of protein engineering and screening. dNIR-GECO1.0 exhibited greater molecular brightness than NIR-GECO2G, robust fluorescence in mammalian cells without exogenous BV supplementation, and a high dynamic range for reporting Ca2+ changes. A detailed mechanistic investigation identified the key mutations within the Ca2+ binding domain that were necessary to convert the inverse response indicator into a direct response indicator. Resonance Raman spectroscopic analysis provided insight into the specific changes in the BV chromophore resulting from the Ca2+-dependent conformational change.
SN  - 2692-8205
ER  -