Abstract

Precise timing detection is essential for exploring ultrafast phenomena in fields ranging from free-electron lasers to ultra-high-power laser facilities. However, achieving simultaneous high resolution and large dynamic range remains a fundamental challenge, and state of the art systems are often constrained by their physical size, power requirements, and limited scalability. Here we introduce an integrated dual electro optic sub cycle timing detector (DEST) that overcomes these limitations. In a proof of principle measurement, the device resolves timing jitter as small as 11 yoctoseconds (ys, 10−24 s) at 1 MHz--equivalent to the transit time of light across two protons--while maintaining an unambiguous measurement range of 6.15 ps and a dynamic range exceeding 155 dB. The core detection unit is miniaturized to chip scale dimensions of 18 mm x 2 mm x 1 mm on a thin film lithium niobate platform, ensuring inherent stability and immunity to environmental disturbances. Moreover, the architecture naturally lends itself to massive parallelization through array integration, with the potential to push timing precision to the sub 10 rontosecond (rs, 10−27 s) level within a 1 m2 footprint. This combination of extreme sensitivity, wide dynamic range, compact size, and scalability opens new avenues for detecting previously inaccessible weak signals, including those from gravitational waves, quantum vacuum fluctuations, and beyond.

Related

  1. TD-Link: A Daisy-Chain Optical Architecture for Integrated Data Readout and Deterministic Timing Distribution in Large-Scale Detector Systems
    Andrea Abba, Gianluca Becuzzi, Matteo Bianchini +8
    arXivPreprintarXiv licenceFull textApplied physics & instrumentationarXiv
  2. Detector-Frame Quantum Limits for Heterodyne Timing in Relativistic Optical Links
    Salman Sajad Wani, Aatif Kaisar Khan, Saif Al-Kuwari +1
    arXivPreprintCC0Full textQuantum physics & quantum informationarXiv
  3. kicad-pycbnew: A Python Framework for Automated, High-Precision PCB Design in Particle Detector Instrumentation
    Vincent Raspal
    HALPreprintCC BY 4.0Full textApplied physics & instrumentationHALarXiv
  4. Precision luminosity measurement in proton-proton collisions at a center-of-mass energy of 13 TeV with the CMS detector at the Large Hadron Collider
    A. Gevorgyan, A. Hayrapetyan, V. Makarenko +2,527
    Physical Review XPeer-reviewedPublisher termsAtomic, molecular & optical physicsCrossref
  5. Precision luminosity measurement in proton-proton collisions at a center-of-mass energy of 13 TeV with the CMS detector at the Large Hadron Collider
    CMS Collaboration
    arXivPreprintCC BY 4.0Full textApplied physics & instrumentationHigh-energy & particle physicsarXiv
BibTeX
@misc{yang2026integrated,
  title = {{Integrated yoctosecond-precision timing detector}},
  author = {Jie Yang and Tong Wang and Yulin Shen and Dehui Pan and Zhichao Chen and Ming-Yang Zheng and Bin Wang and Shaobo Fang and Yi Zhang and Ke Zhang and Jiahui Yao and Minghua Chen and Guorong Wu and Xueming Yang and Ming Xin},
  howpublished = {arXiv},
  year = {2026},
  month = sep,
  doi = {10.48550/arxiv.2609.08192},
  eprint = {2609.08192},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2609.08192},
}
RIS
TY  - UNPB
TI  - Integrated yoctosecond-precision timing detector
AU  - Jie Yang
AU  - Tong Wang
AU  - Yulin Shen
AU  - Dehui Pan
AU  - Zhichao Chen
AU  - Ming-Yang Zheng
AU  - Bin Wang
AU  - Shaobo Fang
AU  - Yi Zhang
AU  - Ke Zhang
AU  - Jiahui Yao
AU  - Minghua Chen
AU  - Guorong Wu
AU  - Xueming Yang
AU  - Ming Xin
PY  - 2026
DA  - 2026/09/08
PB  - arXiv
DO  - 10.48550/arxiv.2609.08192
UR  - https://arxiv.org/abs/2609.08192
AB  - Precise timing detection is essential for exploring ultrafast phenomena in fields ranging from free-electron lasers to ultra-high-power laser facilities. However, achieving simultaneous high resolution and large dynamic range remains a fundamental challenge, and state of the art systems are often constrained by their physical size, power requirements, and limited scalability. Here we introduce an integrated dual electro optic sub cycle timing detector (DEST) that overcomes these limitations. In a proof of principle measurement, the device resolves timing jitter as small as 11 yoctoseconds (ys, 10^−24 s) at 1 MHz--equivalent to the transit time of light across two protons--while maintaining an unambiguous measurement range of 6.15 ps and a dynamic range exceeding 155 dB. The core detection unit is miniaturized to chip scale dimensions of 18 mm x 2 mm x 1 mm on a thin film lithium niobate platform, ensuring inherent stability and immunity to environmental disturbances. Moreover, the architecture naturally lends itself to massive parallelization through array integration, with the potential to push timing precision to the sub 10 rontosecond (rs, 10^−27 s) level within a 1 m^2 footprint. This combination of extreme sensitivity, wide dynamic range, compact size, and scalability opens new avenues for detecting previously inaccessible weak signals, including those from gravitational waves, quantum vacuum fluctuations, and beyond.
ER  -