Skip to content
DraconiticResearch
Search Sources API
203,234 studies31 sourcesUpdated 11 min ago
PreprintCC BY-NC-NDbioRxiv

Measurement-Dependent Parameter Recoverability in Neural Cardiovascular LPN Inference

Abstract

Estimating cardiovascular lumped-parameter network (LPN) parameters from limited hemodynamic observations is a potentially non-unique inverse problem in cardiovascular model personalization. We investigated how parameter recoverability depends on measurement availability and noise, and whether poor recovery reflects limitations of neural inference or insufficient observational information. We developed Mada (measurement-availability and difficulty-aware), a probabilistic neural framework that provides parameter estimates and predictive uncertainty under incomplete observations. Using a closed-loop, four-chamber cardiovascular LPN with time-varying elastance, we generated a synthetic population of 650,000 cases comprising 20 chamber-mechanics and vascular parameters and up to 30 hemodynamic and timing observations. Under complete observations, Mada achieved macro R2 = 0.862, maintaining competitive accuracy across neural baselines while providing parameter-specific uncertainty. Recoverability varied substantially across parameters, with atrial active elastances remaining particularly difficult. For mask-aware Mada, macro R2 ranged from 0.066 with basic clinical measurements to 0.751 with a rich clinical set and 0.842 with all measurements, while uncertainty generally increased as informative measurements were removed. Bounded direct optimization achieved substantially smaller hemodynamic residuals but did not consistently recover the generating parameters. Complementary profile and local-sensitivity analyses revealed case-specific parameter compensation and weak observational directions, while target-specific fine-tuning offered little improvement for difficult atrial parameters. Increasing measurement noise degraded both parameter recovery and predictive-interval coverage, and similar trends were observed with a simpler probabilistic ResMLP. These findings demonstrate that accurate reconstruction of observed hemodynamics does not necessarily imply accurate recovery of the underlying LPN parameters, highlighting the importance of assessing parameter recoverability and predictive uncertainty when physiologically meaningful parameter estimates are sought.

Related

  1. Behavioral Mapping of Hierarchical Dynamical Models Accelerates Bayesian Parameter Inference
    Jingsong Bai, Ayush Pandey
    arXivPreprintCC BY-NC-ND 4.0Full textBioinformatics & computational biologyStatisticsarXiv
  2. Enforcing Thermodynamic Consistency in Parameter Optimization and Bayesian Inference of Biochemical Reaction Networks
    Federica Milinanni, Andrei Kramer-Miehe, Jan Glaubitz +1
    arXivPreprintarXiv licenceFull textCell biologySystems & synthetic biologyarXiv
  3. Parameter non-identifiability limits ecological inference from historical plague mortality records
    N. W. Martin, N. Gauthier
    bioRxivPreprintCC BYFull textEcologybioRxiv
  4. Comparing attenuation parameter and liver stiffness measurement using Hepatus and Fibroscan for the evaluation of steatosis and fibrosis in patients with chronic liver disease: A prospective study
    Cain-En Lim, Ram Prasad Sinnanaidu, Xin Tong Ng +4
    PLOS OnePeer-reviewedCC BY 4.0Developmental biologyPhysiologyPLOS
  5. Topologically-based parameter inference for agent-based model selection from spatiotemporal cellular data
    Alyssa R. Wenzel, Patrick M. Haughey, Kyle C. Nguyen +3
    PLOS Computational BiologyPeer-reviewedCC BY 4.0Full textBiophysicsCell biologyPLOS
BibTeX
@misc{sun2026measurementdependent,
  title = {{Measurement-Dependent Parameter Recoverability in Neural Cardiovascular LPN Inference}},
  author = {Nanlong Sun and Yue Li and Sanjian Zhang and Yurui Chen and Lei Shi},
  howpublished = {bioRxiv},
  year = {2026},
  month = oct,
  doi = {10.64898/2026.10.29.762665},
  url = {https://www.biorxiv.org/content/10.64898/2026.10.29.762665v1},
  note = {CC BY-NC-ND},
}
RIS
TY  - UNPB
TI  - Measurement-Dependent Parameter Recoverability in Neural Cardiovascular LPN Inference
AU  - Nanlong Sun
AU  - Yue Li
AU  - Sanjian Zhang
AU  - Yurui Chen
AU  - Lei Shi
PY  - 2026
DA  - 2026/10/29
PB  - bioRxiv
DO  - 10.64898/2026.10.29.762665
UR  - https://www.biorxiv.org/content/10.64898/2026.10.29.762665v1
AB  - Estimating cardiovascular lumped-parameter network (LPN) parameters from limited hemodynamic observations is a potentially non-unique inverse problem in cardiovascular model personalization. We investigated how parameter recoverability depends on measurement availability and noise, and whether poor recovery reflects limitations of neural inference or insufficient observational information. We developed Mada (measurement-availability and difficulty-aware), a probabilistic neural framework that provides parameter estimates and predictive uncertainty under incomplete observations. Using a closed-loop, four-chamber cardiovascular LPN with time-varying elastance, we generated a synthetic population of 650,000 cases comprising 20 chamber-mechanics and vascular parameters and up to 30 hemodynamic and timing observations. Under complete observations, Mada achieved macro R2 = 0.862, maintaining competitive accuracy across neural baselines while providing parameter-specific uncertainty. Recoverability varied substantially across parameters, with atrial active elastances remaining particularly difficult. For mask-aware Mada, macro R2 ranged from 0.066 with basic clinical measurements to 0.751 with a rich clinical set and 0.842 with all measurements, while uncertainty generally increased as informative measurements were removed. Bounded direct optimization achieved substantially smaller hemodynamic residuals but did not consistently recover the generating parameters. Complementary profile and local-sensitivity analyses revealed case-specific parameter compensation and weak observational directions, while target-specific fine-tuning offered little improvement for difficult atrial parameters. Increasing measurement noise degraded both parameter recovery and predictive-interval coverage, and similar trends were observed with a simpler probabilistic ResMLP. These findings demonstrate that accurate reconstruction of observed hemodynamics does not necessarily imply accurate recovery of the underlying LPN parameters, highlighting the importance of assessing parameter recoverability and predictive uncertainty when physiologically meaningful parameter estimates are sought.
SN  - 2692-8205
ER  -