From Repeatability to Reproducibility in Quantitative Low-Field MRI: A Metrology-Informed Framework for Phantom Evidence.
4 affiliations
- 1Czech Metrology Institute, Okružní 31, 638 00 Brno, Czech Republic.
- 2KAR BioTech s.r.o., Náměstí Sítná 3105, 272 01 Kladno, Czech Republic.
- 3Faculty of Biomedical Engineering, Czech Technical University in Prague, Náměstí Sítná 3105, 272 01 Kladno, Czech Republic.
- 4Institute of Automation, Informatization, and Measurement, Faculty of Mechanical Engineering, Slovak University of Technology in Bratislava, Námestie Slobody 17, 812 31 Bratislava, Slovakia.
Abstract
Low-field magnetic resonance imaging includes portable and open architectures, but quantitative results remain sensitive to field strength, temperature, environment, system state, acquisition, reconstruction, and model fitting. This methodological review asks what evidence supports claims of repeatability, intermediate precision, reproducibility, qualified reference-linked bias, measurement uncertainty, and use relevance. We conducted a targeted synthesis of empirical low-field reports, quantitative-imaging methods, metrology guidance, and MRI standards using a documented search and explicit source-classification criteria. The resulting framework separates three independent axes: represented precision conditions, strength of reference linkage, and relevance to the intended technical or clinical use. Each claim is linked to an experimental design, statistical estimand, configuration record, uncertainty model, and decision rule. An explicitly synthetic low-field T1 example illustrates design identifiability, precision-based replication planning, mixed-effects analysis, an uncertainty budget, and a guard-banded technical decision; it is not experimental validation. A staged pathway allows laboratories to begin with provenance, constancy, and within-system repeatability before progressing to reference-linked or multicentre studies. Meeting a phantom threshold establishes only the specified technical property under the tested conditions; it does not establish diagnostic utility, clinical benefit, regulatory conformity, or CE marking. The framework is an operational synthesis, not a replacement standard or validated quality score.
Related
- A statistical framework for evaluating the repeatability and reproducibility of large language models
- Repeatability and reproducibility of spectral results with clinical photon-counting CT: multi-center phantom study
- A mechanistic quantitative systems pharmacology framework enriched by multiscale data enables model-informed translational development of mesenchymal stem cell therapy in lupus nephritis.
- Long‐term stability and reproducibility of frozen plasma control samples for hepatitis B virus, hepatitis C virus, and human immunodeficiency virus by quantitative PCR: Implications for retrospective testing in hemovigilance
- Quantitative flow ratio (QFR) in routine practice: diagnostic performance and reproducibility
BibTeX
@article{kolarova2026from,
title = {{From Repeatability to Reproducibility in Quantitative Low-Field MRI: A Metrology-Informed Framework for Phantom Evidence.}},
author = {Helena Kolarova and Jitka Hanusova and Jan Kavalirek and Martin Halaj and Jiri Tesar},
journal = {Journal of imaging},
year = {2026},
month = oct,
doi = {10.3390/jimaging12110540},
url = {https://europepmc.org/article/MED/43082930},
note = {CC BY},
}
RIS
TY - JOUR
TI - From Repeatability to Reproducibility in Quantitative Low-Field MRI: A Metrology-Informed Framework for Phantom Evidence.
AU - Helena Kolarova
AU - Jitka Hanusova
AU - Jan Kavalirek
AU - Martin Halaj
AU - Jiri Tesar
PY - 2026
DA - 2026/10/29
JO - Journal of imaging
DO - 10.3390/jimaging12110540
UR - https://europepmc.org/article/MED/43082930
AB - Low-field magnetic resonance imaging includes portable and open architectures, but quantitative results remain sensitive to field strength, temperature, environment, system state, acquisition, reconstruction, and model fitting. This methodological review asks what evidence supports claims of repeatability, intermediate precision, reproducibility, qualified reference-linked bias, measurement uncertainty, and use relevance. We conducted a targeted synthesis of empirical low-field reports, quantitative-imaging methods, metrology guidance, and MRI standards using a documented search and explicit source-classification criteria. The resulting framework separates three independent axes: represented precision conditions, strength of reference linkage, and relevance to the intended technical or clinical use. Each claim is linked to an experimental design, statistical estimand, configuration record, uncertainty model, and decision rule. An explicitly synthetic low-field T1 example illustrates design identifiability, precision-based replication planning, mixed-effects analysis, an uncertainty budget, and a guard-banded technical decision; it is not experimental validation. A staged pathway allows laboratories to begin with provenance, constancy, and within-system repeatability before progressing to reference-linked or multicentre studies. Meeting a phantom threshold establishes only the specified technical property under the tested conditions; it does not establish diagnostic utility, clinical benefit, regulatory conformity, or CE marking. The framework is an operational synthesis, not a replacement standard or validated quality score.
SN - 2313-433X
ER -